Lever operated spherical valve with brushed chrome brass body, EPDM O-rings and PTFE gaskets. The valve incorporates a stainless steel filter with EPDM O-ring and brass filter plug. The compression connection is to be used with for polyethylene pipe PE100 to EN12201. Maximum working pressure 25.0 bar. Cold water use only.
Range of spherical valves with brass (CW617N) or DZR brass (CW511L) bodies (chrome plated, nickel plated or without plating - see model), chrome plated brass ball and a range of different operating members (see model). Compression connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ball valves with nickel plated brass bodies, chrome plated brass ball, PTFE seats, and either lever or T handle operating members (see models). Maximum working pressure 16.0 to 64.0 Bar (Size & model dependant, see models) Maximum working temp 85°C
Range of lever operated spherical valves with nickel plated brass or DZR brass bodies, chrome plated brass ball and PTFE seat. Maximum working pressure is 40.0 bar for ¼” to 2” and 25.0 bar for 2½” to 4”. Maximum operating temperature 100°C.
Range of spherical valves (inline, angled and tee) with chrome plated brass bodies and ball. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of spherical valves with nickel plated brass bodies, chromium plated brass balls, PTFE seals, NBR and/or FKM ‘O’-rings. 140, 140M, 141 & 141M series models incorporate a stainless-steel strainer. 140 & 141 series models also incorporate a magnet. The 121 & 122 series models are 3-way valves. Maximum working pressure: See PN in brackets under model. Maximum operating temperature: Cold water use only.
Range of resilient seated gate valves with blue epoxy coated ductile iron bodies, and an EPDM wedge, gasket and ‘O’-ring. The MV40-AAAAXY (model has a rising spindle, the MV40-AAAAX model has a non-rising spindle, both have a handwheel operating member. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of gate valves with a non-rising spindle and a handwheel operating member with a brass body and brass wedge. For use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of magnetic scale reducers with metal bodies, for use with copper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar. Cold water use only.
Range of ozone cleaning units with a plastic body. The water which is discharged from these units is intended to be used for cleaning surfaces. The products incorporate a filter (cartridge and housing), pressure regulator and a stainless-steel strainer at the inlet. The flow is controlled via a metal solenoid which is operated by a switch on the front panel. Maximum working pressure 5.0 bar. Cold water use only.
Range of drinking water stations. Flow is controlled via a push-button tap assembly (which incorporates a flow regulator) on all models. Model Park Tap 016 0104-TS-016_WRAS incorporates two outlets (bubbler at low-level & bottle filler at high-level). The flexible hose assembly which rises through the body of the station to the lower outlet incorporates a single check valve assembly (verified by test as suitable for backflow protection against Fluid Category 2). Model Hall TAP_EN (indoor) incorporates one (bottle filler type) outlet with a fixed drip tray under. Street Tap 0104-TS003_WRAS incorporates one (bottle filler type) outlet. The flexible hose assembly which rises through the body of the station to the outlet incorporates a single check valve assembly (verified by test as suitable for backflow protection against Fluid Category 2). Maximum working pressure 3.5 bar. Cold water use only.
'DURACON® M25-44 WK2001, M90-44 WK2001 & M270-44-WK2001'. White coloured, injection moulded POM materials. For use with water up to 85°C.
`4300314` (grey coloured) & '4300315' (black coloured). Injection moulded ABS material. For use with water up to 85°C.
'Endolac 245.30 FGC'. Factory applied, black coloured, bituminous coating. Apply as per manufacturer's technical data sheet dated 04/05/2022. Cure for 7 days@20°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Eurokote® 448 Bleu 5005 & Eurokote® 448 Bleu 5002'. Factory applied, blue coloured, two-part epoxy coatings consisting of a resin and hardener. Mix resin and hardener in a 1:1 volume ratio and apply as per manufacturer's technical data sheet version dated '29/08/17'. Cure for 7 days@20°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'S' epoxy powder coating. Factory applied, blue coloured epoxy powder coating. Apply as per manufacturer's instructions 'SNC-EP09V1 - date 2009/12/1'. Cure for 24 hours@30°C. For use with water up to 50°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Eurokote 468 Thixo Brun Rouge'. Factory applied, red/brown coloured, two-part epoxy coating consisting of a resin and hardener. Mix resin and hardener in a weight ratio of 77:23 and apply as per manufacturer's Data Sheet dated '10/05/2019'. Cure for 10 days@20°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Powercron® 451 A – CP 573 B ITT Lowara'. Factory applied, blue coloured cationic resin coating. Apply as per manufacturer's technical data sheet 'LT/I-21-090' dated 'Sep 9, 2021'. Cure for 20 minutes@180°C. For use with water up to 50°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Eurokote 468 Thixo Brun Rouge 500'. Factory applied, red/brown coloured, two-part epoxy coating consisting of a resin and hardener. Mix resin and hardener in a weight ratio of 70:30 and apply as per manufacturer's Technical Data Sheet version edit '23/01/202. Cure for 10 days@20°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'EXCELLUBE B300'. Factory applied, black coloured PTFE (low friction) coating. Apply as per instructions ‘issue 1’, dated 23.01.18. Cure for 20 minutes@240°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'NOA FWT BUFF/NOA FWT WHITE (ORGA1000 NOA BUFF/ORGA 1000 NOA WHITE). NOA FWT BUFF/NOA FWT BULE (ORGA1000 NOA BUFF/ORGA 1000 NOA BULE). NOA FWT BUFF/NOA FWT CREAM (ORGA1000 NOA BUFF/ORGA 1000 NOA CREAM)'. Factory applied, two-component white, blue & cream coloured epoxy coatings. Mix base and hardener in a 3.71:1 volume ratio and apply as per manual reference '14-11' dated 'July 2019 (ES)'. Cure for 16 hours@23°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'PMSP5108-M'. Factory applied, blue coloured enamel coating. Apply as per manufacturer's user manual 'edition 01', dated '14/10/2020'. Cure for 5 minutes@840°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Eurokote 480 FC'. Site applied, red coloured (once mixed), two part epoxy coating consisting of a resin and hardener. Mix, apply and cure (fully dry) in accordance with manufacturer's technical data sheet dated 23/09/2021. For use with water up to 23°C.
'UPS 505 WAU Blue & Grey'. Site applied, two-component polyurethane coatings which are available in blue or grey colours (once mixed). Mix Part A (blue or grey opaque liquid) with Part B (amber, translucent liquid) in a 100:30.5 weight ratio and apply as per manufacturer's technical data sheet ‘TDS – UPS505WAU - Version 6 – August 2022'. Cure for 14 days@7°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'Belzona 5892'. Site applied, epoxy coating consisting of Belzona 5892 (white – Parts A & B) & Belzona 5892 (grey – Parts A & B). Belzona 5892 (white – Parts A & B) are mixed in a weight ratio of 5.7:1 and then applied as a first coat (no cure) in accordance with manufacturer’s instructions for use ‘FN10106’, publication number ’04-11-20(01)’. Belzona 5892 (grey – Parts A & B) are mixed in a weight ratio of 5.7:1 and then applied to the white in accordance with manufacturer’s instructions for use ‘FN10106’, publication number ’04-11-20(01)’. The final coating is then cured for 24 hours@30°C. For use with water up to 85°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
‘Polycor LP Gel Coat reinforced with Norsodyne H 13212 TAE laminating resin’. ‘NORSODYNE H 13212 BTAE laminating resin’ was added to the approval in July 2024. ‘Polycor LP Gel Coat’ is a brush or spray applied polyester resin gel coat, available in white or grey colours and is reinforced with Norsodyne H 13212 TAE or NORSODYNE H 13212 BTAE glass fibre laminate. Apply the brush grade as per manufacturer’s technical data sheet ‘7100’ dated 10.10.17 and apply the spray grade as per manufacturer’s technical data sheet ‘7200’ also dated 10.10.17. Cure for 24 hours@25°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'YD-PEX' hose. Natural (white coloured), extruded single layered PEX hose. In May 2024 ‘YD-PEX-BL’ hose was added to the approval. Black coloured, extruded, single layered PEX hose. Both are for use with water up to 85°C.
'420 OE UHMWPE'. Multi-layered (7 layers), Ultra High Molecular Weight Polyethylene hose manufactured by wrapping on a mandrel. The inner layer is white coloured polyethylene, and the outer layer is blue coloured rubber. For use with water up to 23°C.
'Sinopec Drinking Water Pipeline Sealing Lubricant (Product Code: 523478)'. White coloured lubricant. Apply as per manufacturer's instructions. For use with water up to 85°C.
'Berulub FO 34'. White coloured lubricant. For use with water up to 85°C.
'POLYPOL-1045'. Yellow coloured, contact moulded Isophthalic Unsaturated Polyester Resin material. For use with water up to 50°C.
'BorSafe ME3440 (black)'. Black coloured, extruded polyethylene material. For use with water up to 60°C.
'BorSafe HE3490-LSH'. Black coloured, extruded polyethylene material. For use with water up to 60°C.
'Ryton R-4-244NA (beige coloured) & Ryton R-4-244NA ECHO RP and Ryton R-4-244BL & Ryton R-4-244BL ECHO RP (black coloured)'. Injection moulded PPS materials. For use with water up to 85°C.
‘Wouper EG30WF, EG40WF & EG50WF’. Injection moulded, glass filled (30% - 50%) PPA materials available in natural (appears off-white), black and grey. ‘Wouper EG30WF, EG40WF & EG50WF’ natural, black & grey are for use with water up to 85°C. ‘Wouper AG30WF’. Injection moulded, glass filled (30%) PPA materials available in natural (appears off-white), black & grey. ‘Wouper AG30WF’ natural & black are for use with water up to 85°C. Between July 2022 and January 2023, ‘Wouper AG30WF’ grey is for use with water up to 23°C. From February 2023, ‘Wouper AG30WF’ grey is for use with water up to 85°C.
'Monotape 12, 24 B, 24 BB, 24 HD & 25 BI'. White coloured PTFE tapes manufactured by extrusion, stretching and calendaring. '24 SH, 20SH, 30SH & 28LS-LE'. White coloured PTFE gasket sheets manufactured by extrusion, stretching, sintering and calendaring. For use with water up to 85°C.
'TCM585RE'. Red coloured chemical anchor resin supplied in a pre-weighed dual cartridge. Apply as per manufacturer's instructions dated '21.07.2021'. Cure for 48 hours@7°C. For use with water up to 23°C. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘2KPS EASF-VE’. Site applied, two part, grey coloured anchor resin. 2KPS EASF-VE is light grey coloured when mixed and consists of Part A (shiny grey coloured liquid) & Part B (shiny off-white coloured liquid). Mix, apply and cure as per manufacturer’s product information sheet 'EASF-V / VC / VE (EU07) V4.0'. For use with water up to 23°C. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water.
'4360 'O' rings, washers, membranes and lip seals'. Black coloured, injection moulded EPDM components with a shore hardness of 60. The ‘O’ rings have a tested in-radius size of 1.31mm. The washers have a tested in-radius size of 1.05mm. The membranes have a tested in-radius size of 1.55mm. The lip seals have a tested in-radius size of 0.40mm. For use with water up to 85°C.
‘EWA 12150 (EW48) Rev.1. EWA 12155A (EP55) Rev.1. EWA 12160A (EW 60) Rev.1. EWA 12165 (EW65 2GS) Rev.1. EWA 12170 (WRC 70) Rev.1. EWA 12175 (WRC 75) Rev.1. EWA 12180 (EW80) Rev.1’. Black coloured, compression moulded, EPDM sheet materials. Shore hardness between 50 & 80. Tested in-radius size 1.2mm. For use with water up to 85°C.
‘KRE 60 (103), KRE 65 (100) & KRE 65 (106)’. In September 2022 ‘KRE 60 (104)’ was added to the approval. Black coloured, compression moulded EPDM rubber materials. Shore hardness 60 & 65. Tested in-radius size 1.0mm. For use with water up to 60°C.
'6741'. Brown coloured, compression moulded FKM rubber. Shore hardness 70. Tested in-radius size 1.0mm. For use with water up to 85°C.
'SL70L41F'. Blue coloured, compression moulded silicone rubber material. Shore hardness 70. Tested in-radius size 1.1mm. For use with water up to 85°C.
'Permabond ET5365'. Site applied, grey coloured, two-component epoxy adhesive consisting of part A (light grey coloured paste) & part B (dark grey coloured paste). The product cartridge is heated to 30°C and the two-components are mixed in a 2:1 volume ratio. Apply as per manufacturer's TDS 'revision 1', dated 23 May 2018. Cure 24 hours@23°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Interflon Paste HT1200'. Cream coloured ceramic paste. Apply as per manufacturer's instructions, document number 'IFUHT1200' dated 24/04/2017. Cure for 5 minutes@22°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
WC flushing cisterns incorporating a BS 1212-4 side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Spring loaded resilient trim in-line check valve cartridge with acetal body, incorporating a stainless steel spring and EPDM ‘O’-rings. To be housed in a specifically dimensioned body. Maximum working pressure 16 Bar. Maximum operating temperature 65°C
Spring loaded resilient trim in-line check valve cartridge with acetal body, incorporating a stainless steel spring and NBR or EPDM ‘O’-rings. To be housed in a specifically dimensioned body. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C
Range of non-verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in DZR brass bodies. Maximum working pressure 16.0 bar Maximum operating temperature 85°C
Non-verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Page 28 of 131
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.