Range of single-hole, single outlet, (fixed) combination tap assemblies (brass bodies – various finishes), incorporating non-rising spindle headworks and single lever or dome type operating members. The spout outlet incorporates a plastic aerator. Supplied with a lever type pop up waste – not tested. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with (brass bodies - various finishes), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Models 6500H/W & 6504/W are supplied with a click type waste – not verified by test. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assemby (brass body, various finishes - see model), incorporating a ceramic cartridge with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assemby (brass body, various finishes - see model), incorporating a ceramic cartridge with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
---|---|---|---|---|---|---|---|---|---|---|---|
235038 X XXX | VARIOUS | 1/2" BSP | 10.0 bar | 65 °C | PPI | ON REAR OF BODY | No | Ceramic cartridge | C-plate | Aerator & Flow Straightener | |
223238 X XXX | VARIOUS | 1/2" BSP | 10.0 bar | 65 °C | PPI | ON REAR OF BODY | No | Ceramic cartridge | C-plate | Aerator & Flow Straightener |
X XXX Denotes the following: First X: Different handle option and the second, third & fourth XXX for different finishes: Handles : A (Lever type) Chrome – No suffix, Brushed brass – BGP, PVD Gold – PVD, Brushed Nickel – BN1, Gun Metal – GMG, Matt Black – MBK, Matt White – MWH, Stainless Steel – SS1, Black Chrome – BCP, Titanium – TIB and Antique Bronze – AB1.
Single hole single outlet (fixed) combination tap assemblies (chrome plated), with a ceramic cartridge headwork and flow straighter in the spout outlet. Supplied with a click type waste (verified by test). Maximum working pressure - 5.0 bar. Maximum operating temperature - 60 °C.
Single hole single outlet (fixed) combination tap assemblies (chrome plated), with a ceramic cartridge headwork and flow straighter in the spout outlet. Supplied with a click type waste (verified by test). Maximum working pressure - 5.0 bar. Maximum operating temperature - 60 °C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass) bodies, incorporating non-rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. Product supplied with a surface mounting kit comprising of Stainless steel braided EPDM lined flexible hose assemblies incorporating ½” BSP captive nut end connections with 15x15mm compression isolation valves that incorporate single check valve cartridges, however, the complete assembly has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Floor standing, single hole, single outlet (swivel) combination tap assembly with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member and a manual diverter to a shower outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
A deck mounted two hole, single outlet (fixed) combination tap assembly, with a brass body (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The product is supplied with metal back nuts and plastic aerators. Maximum working pressure: 5.0 bar. Maximum operating temperature: 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass body), incorporating ceramic cartridge headwork with single lever operating member. The headwork and the spout are connected by a PEX lined flexible hose. The spout outlets incorporate a plastic aerator, and the products are supplied with metal backnuts. Models supplied with pop-up waste – not tested. Maximum working pressure 10 Bar. Maximum operating temperature 70°C.
Deck mounted, two-hole, single outlet (fixed) combination tap assemby (brass body, various finishes - see model), incorporating ¼ turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) combination tap assembly (brass body, various finishes - see model), incorporating ¼ turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
---|---|---|---|---|---|---|---|---|---|---|---|
223206 X XXX | VARIOUS | 3/4" BSP | 10.0 bar | 85 °C | PPI | REAR OF BODY | No | 1/4 Turn ceramic disk | Metal Backnuts | Flow Straightener |
X XXX Denotes the following: First X: Different handle option and the second, third & fourth XXX for different finishes: Handles : without suffix indicates no handle / different handle option – A (Lever type) Chrome – No suffix, Brushed brass – BGP, PVD Gold – PVD, Brushed Nickel – BN1, Gun Metal – GMG, Matt Black – MBK, Matt White – MWH, Stainless Steel – SS1, Black Chrome – BCP, Titanium – TIB and Antique Bronze – AB1.
Range of wall and deck mounted thermostatic combination tap assemblies (brass bodies – various finishes), incorporating a two way ceramic disc diverter headwork controlling the flow from spout outlet to shower outlet using dome type operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button with dome type operating members. The spout outlet incorporates a plastic aerator. The inlets incorporate an approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
---|---|---|---|---|---|---|---|---|---|---|---|
223205 X XXX | VARIOUS | 3/4” BSP | 10.0 bar | 65 °C | PPI | ON REAR OF BODY | No | 1/4 Turn ceramic disk | Metal Backnuts | Flow Straightener | Shower Hose, Handset, |
X XXX Denotes the following: First X: Different handle option and the second, third & fourth XXX for different finishes: Handles : without suffix indicates no handle / different handle – A (Lever type) Chrome – No suffix, Brushed brass – BGP, PVD Gold – PVD, Brushed Nickel – BN1, Gun Metal – GMG, Matt Black – MBK, Matt White – MWH, Stainless Steel – SS1, Black Chrome – BCP, Titanium – TIB and Antique Bronze – AB1.
Range of two hole, deck mounted, single outlet (fixed), combination tap assemblies (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to the shower outlet. The outlet incorporates an elbow to connect a shower hose to the headset. The spout outlet incorporates an aerator, and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted two hole, single outlet, fixed combination tap assembly (brass bodies - various finishes). Incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to a shower outlet. The spout outlet incorporates a plastic aerator. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10 Bar. Maximum operating temperature 60 °C.
Range of two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of two hole, double outlet (swivel) combination tap assemblies (chrome plated brass). (T-695 series) Incorporates quarter turn ceramic disc headworks with single lever operating members. (T-695M series) incorporates non-rising spindle headworks and dome or cross top type operating members (T-695M). The spout outlets incorporate a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Three-hole, single outlet (fixed) combination tap assembly (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided PEX lined flexible hose assemblies. The product is supplied with a flow regulator and lever type pop up waste, not verified by test. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted three-hole, single outlet (fixed) combination tap assemblies (chromium brass bodies). Incorporating quarter turn ceramic disc headworks and lever type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 70.0°C
Three-hole, deck mounted single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The headworks are connected to the spout with stainless steel braided PEX lined flexible hose assemblies. The spout outlet incorporates a plastic aerator. Supplied with a lever type pop up waste, not verified by tested. Maximum working pressure 10.0 Bar. Maximum operating temperature 60.0°C.
Range of three-hole, wall mounted single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with cross top operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of three-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headwork with either single lever, dome, wheel or cross top operating members. The headworks are connected to the spout with stainless steel braided braided PEX lined flexible hose assemblies. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted spout outlet (Chrome finish). The spout outlet incorporates a plastic aerator. Open outlet use only. Maximum operating temperature 60.0°C
Floor standing spout outlet (chromium plated brass) incorporating a plastic aerator and a concealed brass floor mounting. Maximum operating temperature 60°C.
Range of chemical dosing equipment which incorporate self-closing valves within a plastic body with EPDM o-rings. The outlet of the injector incorporates a connection for injection of chemicals via venturi action. Only suitable for use with chemicals no greater than a FC3, additional backflow protection is required for chemicals greater than FC3. Maximum working pressure 9.0 bar. Maximum operating temperature 70ºC.
‘LFLF10xx’ range of stainless steel press-fit fittings incorporating EPDM ‘O’-rings for use with ‘LFLP1001’ stainless-steel pipe. Jointing is achieved via a crimping tool using a ‘M’ profile. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘CFxx and TFxx’ range of brass compression fittings for use with copper pipes and Irish copper pipe (both manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperatures: CF15 and CF16 models: 65°C. All other models: 85°C.
‘Universal Transition Coupling (UTC)’ range of plastic compression fittings for use with the following pipe types and sizes: Stainless steel (manufactured to ASTM A554/ BS EN 10312): ¾”, 1” & 1¼”. Galvanised (EN 10255): ¾”, 1”, 1¼”, 1½” & 2”. Copper (BS EN 1057): 15mm, 22mm & 28mm. PVC (BS EN 1452): 20mm & 2”. ABS (BS 5391-1): 20mm, 25mm & 32mm. PE80 & PE100 pipe (to BS EN 12201): 20mm, 25mm, 32mm, 50mm & 63mm. For use above and below ground. Maximum working pressure 12.5 bar. Cold water use only.
Range of Copper and Brass push fit fittings. Brass fittings are for use with PB pipe (manufactured to BS7291-2) & Copper pipe (manufactured to BS EN 1057) only. Copper fittings are for use with PB pipe (manufactured to BS7291-2), PE-X pipe (manufactured to BS7291-3) & Copper pipe (manufactured to BS EN 1057). Maximum working pressures and operating temperatures when used with: PB & PEX pipe – 3.0 bar and 92°C, 20.0 bar cold water. Copper pipe – 20.0 bar and 100°C.
Flomasta Range of plastic, push-fit fittings (wall plate elbow, equal elbow, end stop, pipe insert, equal straight and equal tee) for use with MDPE pipe (manufactured to BS EN 12201), for above and below ground use. Copper adaptors are for use with PB pipe (manufactured to BS7291-2), PEX pipe (manufactured to BS7291-3) or Copper pipes (manufactured to BS EN 1057) and are for above ground use only. Maximum working pressure 16.0 bar. Cold water use only.
Range of float operated electrical switches with plastic bodies. Open outlet and cold water use only.
Range of WC dual flush drop valves with an ABS body and silicone seal. The valves are operated via a push button or lever assembly for either full or reduced flush and incorporate an internal adjustable height overflow. Cold water use only.
‘Altair V4’ range of in-line and manifold volumetric water meters with brass or plastic bodies (see models), the products can be provided with a plastic strainer. Maximum working pressure 16.0 bar. Cold water use only.
Range of ultrasonic water meters with plastic bodies and plastic strainers at the inlets. Specific models (see models) incorporate an optional non return valve (not suitable for backflow protection). Maximum working pressure 16.0 Bar. Maximum operating temperature 90°C.
WSTsb range of bulk water meters with blue polyester coated cast iron bodies. Maximum working pressure 16.0 Bar Maximum operating temperature 50.0°C
Range of electromagnetic water meters with stainless steel bodies and a polyamide coating. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with brass bodies, plastic turbines and plastic strainers on inlets. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Top entry compression cylinder flange with DZR brass body and copper anti-aeration dip tube. The compression connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 4.0 bar. Maximum operating temperature 60°C.
Leak detection system, comprising of a flow sensor with a stainless-steel body incorporating a motorised spherical valve, with a stainless-steel ball. Please note that claims of leak detection have not been verified by WRAS. Maximum working pressure 15.0 bar. Maximum operating temperature 85°C.
Brass flow meter and smart box water monitoring system. Maximum working pressure 3.0 Bar Maximum operating temperature 65.0°C
Range of installation kits comprising of a water block, double check valve assembly (suitable for backflow protection against fluid category 3) and a pressure reducing valve (outlet pressure range 3.0 to 3.5 bar). Model 95428 incorporates a water filter. Maximum working pressure: 16 Bar Maximum operating temperature: 23°C
Range of cold water booster sets comprising of multistage stainless steel pumps and manifolds with a common control panel and motor mounted inverters. The products incorporate spherical valves between the inlet and outlet manifolds and the pumps. The outlet manifold incorporates an anti-head loss valve and a flow through valve with an expansion vessel factory pre-set at 10.0 bar. Maximum working pressure 10.0 bar. Cold water use only.
Range of multistage centrifugal pumps with stainless steel impellers, intermediate chambers, shaft and outer sleeve. The Movitec VME models can also incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressures: Comeo C models 10.0 bar, Movitec VM models with an oval flange or VME models with integral check valve 16.0 bar, All other Movitec VM models 25.0 bar Maximum operating temperatures: Comeo C and Movitec VME models with integral check valve 60°C, all other model variants 100°C.
Permanent magnet multi-stage centrifugal pump with a plastic body. The product is supplied with brass adaptors and a copper olive to convert to compression. The compression connections are for use with Irish copper pipe (manufactured to EN1057) (27.4mm size) and copper pipe (manufactured to EN1057) (28mm size). Maximum working pressure 8.0 bar. Maximum operating temperature 90°C.
Range of overhead shower outlets brass and stainless-steel bodies in various finishes, incorporating stainless steel filter washers and flow regulators. Open outlet use only. Maximum operating temperature 85⁰C.
Range of wall and ceiling mounted overhead shower outlets, (plastic bodies – various finishes). Both models incorporate a built-in pressure regulator. Maximum operating temperature 85°C. Open outlet use only
Range of deck mounted pull out kits (various finishes) comprising of a shower handset, shower hose and a stainless steel braided silicone lined connecting hose. The shower handsets incorporate single check valve cartridges, however, the complete product has not been fully tested to demonstrate backflow protection. Maximum operating temperature: 60°C. Open outlet use only.
Page 220 of 222
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.