Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a thermostatic cartridge headwork controlling temperature with a manual override and a quarter turn ceramic disc controlling flow with a manual override and available with a range of dome and lever operating members. The assemblies also incorporate a lockable self-cancelling diverter to shower outlet. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Three hole single outlet trim sets consisting of two ceramic disk headworks and a spout with a flow straightener. Various operating members (see model section). V246 prefix model is a wall mounted spout with a flow straightener only. The products are brass bodied and available in various finishes (see model). Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Three hole, single outlet (fixed) combination tap assembly (chromium plated brass). Incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator, and the product is supplied with a pop-up waste and stainless steel braided, PEX lined hose assemblies for connecting the headworks to the spout outlet. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headwork with a single lever operating member and self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose. Maximum working pressure 10.0 Bar. Maximum operating temperature 60 °C.
Spout outlet with brass body, incorporating aerator, available in different finishes. Maximum operating temperature 65°C.
In-line water filter system comprising of a head and replaceable carbon block cartridge (within a fixed housing) for use with John Guest LLDPE pipe. Maximum working pressure 8.6 bar. Cold water use only.
Range of solder ring copper fittings for use with copper tube to EN 1057. The 304756, 110804, 304574, 304615 & 304711 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘WSR S/R’ Range of solder ring copper fittings for use with copper tube to BS EN 1057. Maximum working pressure 16 bar. Maximum working temperature 99°C
Range of compression fittings with brass brass bodies for use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘KSO’ range of compression fittings with brass or chrome plated brass bodies for use with copper pipe (manufactured to EN1057). The KSO14 sand KSO15 tap connector models incorporate an EPDM washer. Maximum working pressure 16.0 bar. Maximum working temperature 85˚C
Timco - Elysee range of Polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Jason range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of black coloured, PE100 butt fusion fittings for use with PE100 pipes (manufactured to EN 12201). Maximum working pressure for fittings used with SDR11 pipe is 16.0 bar and for fittings used with SDR17 pipe is 10.0 bar. For above and below ground use. Cold water use only.
Range of end feed copper fittings for use with copper tube to EN 1057. The 950513, 950514, 950501, 950503 & 950502 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Brass fitting Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of water meters with blue epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Cold water use only.
Page 192 of 578
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.