Range of longitudinal (EFW) welded stainless steel (Grade 304/304L & 316/316L) pipes. Maximum working pressures: 1¼” sch 10: below ground = 55.0 bar. Above ground = 74.0 bar. 1½” sch 10: below ground = 48.0 bar. Above ground = 64.0 bar. 2” sch 10: below ground = 38.5 bar. Above ground = 51.0 bar. 2½” sch 10: below ground = 34.5 bar. Above ground = 46.0 bar. 3” sch 10: below ground = 28.0 bar. Above ground = 38.0 bar. 4” sch 10: below ground = 22.0 bar. Above ground = 29.0 bar. 5” sch 10: below ground = 19.5 bar. Above ground = 26.0 bar. 6” sch 10: below ground = 16.0 bar. Above ground = 22.0 bar. 8” sch 10: below ground = 14.0 bar. Above ground = 18.0 bar. ½” sch 40 & ¾” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 1” sch 40: below ground = 30.0 bar. Above ground = 40.0 bar. 1¼” sch 40 & 1½” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 2” sch 40: below ground = 54.5 bar. Above ground = 72.0 bar. 2½” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 3” sch 40: below ground = 52.0 bar. Above ground = 69.0 bar. 4” sch 40: below ground = 44 bar. Above ground = 58.0 bar 5” sch 40: below ground = 38.5 bar. Above ground = 51.0 bar. 6” sch 40: below ground = 35.0 bar. Above ground = 46.0 bar. 8” sch 40: below ground = 31.0 bar. Above ground = 41.0 bar. Maximum operating temperature 100°C.
‘Super Speedfit’ range of plastic pushfit fittings (black, light grey, dark grey, white, natural, and red) for use with John Guest LLDPE tubing (blue, black, natural, green, orange, red, white and yellow). Operating parameters: 5/32”, ¼”, 5/16”, 4mm & 6mm = 16.0 bar cold water & 8.0 bar at 65°C. 3/8” = 10.0 bar cold water & 7.0 bar at 65°C. ½” = 10.0 bar cold water & 6.0 bar at 65°C. 8mm, 12mm & 15mm = 10.0bar cold water & 6.0 ba at 65°C. 10mm = 10.0bar cold water & 7.0 bar at 65°C.
‘Flowflex’ and ‘Lamontite’ ranges of brass, chromium plated brass, nickel plated brass and DZR brass compression fittings for use with copper pipe (manufactured to to BS EN1057:2006 + A1:2010). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Primaflow ranges of brass, DZR brass, chromium plated brass, nickel plated brass and DZR brass compression fittings for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of ‘Superseal’ and ‘Speedfit’ push-fit fittings with acetal body’s (black or light grey) and NBR ‘O’ rings. For use with John Guest LLDPE tubing (Speedfit port only) and 316 stainless steel tubing manufactured to EN10088 (Superseal push-fit port only). Pipe inserts must be used for the LLDPE tube sizes 3/8” and ½”. Maximum working pressure: See models below. For cold water use only.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
‘Wesan WP’ range of water meters with black epoxy coated cast iron bodies, plastic impellers and EPDM ‘O’-rings and lip seal (DN50-65 models) and EPDM ‘O’-rings and gasket + NBR ‘O’-ring (DN80-125 models). Maximum working pressure 16.0 bar. Cold water use only.
Range of water meters with brass bodies, plastic turbines and EPDM washers. Inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of water meters with (blue epoxy coated) brass bodies and plastic working chamber. The inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
‘H5000’ range of helical rotor, bulk water meters with blue epoxy coated cast iron bodies and nitrile `O` rings. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meters with blue epoxy coated ductile iron bodies, plastic measurement chambers and vanes and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with brass bodies, plastic turbines and EPDM washers. Inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
‘V210’ range of volumetric water meters with brass bodies and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Cold water use only.
‘V200’ range of rotating piston (semi positive) volumetric in-line water meters with brass bodies, EPDM ‘O’-rings and seal (DN40 model only), NBR ‘O’-rings (all other models) and seal (DN15 36RPL model only). Maximum working pressure 16.0 bar. Cold water use only.
‘V110’ range in-line volumetric water meters with black plastic bodies. Maximum working pressure 16.0 bar. Cold water use only.
Range of in-line plastic flow restrictors housed within black or grey glass fibre reinforced nylon bodies. Maximum working pressure 16.0
Non-metallic materials and components comply with BS6920 at 85°C
‘Homebooster’ pump with stainless steel body, plastic impeller and EPDM rubber ‘O’-rings. The product is supplied with two loose brass ¾” captive nut x ½” BSP (M) connectors and fibre gaskets for installation on the inlet and outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of water pressure booster sets with a cold water storage cistern and booster pump. All models incorporate a non-return valve, not suitable for backflow protection. These models have an AG air gap suitable for fluid category 3 protection. Maximum working pressure 6.0 bar. Cold water use only.
Range of water pressure booster sets with a cold water storage cistern and booster pump. All models incorporate a non-return valve, not suitable for backflow protection. These models have an AB air gap suitable for fluid category 5 protection. Maximum working pressure 6.0 bar. Cold water use only.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Page 169 of 427
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.