Range of wall mounted, concealed, three hole single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn, ceramic disc headworks with cross top (14415W-3-CP) or single lever (14415W-4-CP) operating members. The spout outlet incorporates a plastic aerator. Maximum operating temperature 60°C. Maximum operating pressure 4.1 bar.
Range of deck mounted three hole single outlet (fixed) combination tap assemblies with brass bodies (chromium plated), incorporatinig ceramic disc headworks with cross top (14428W-3-CP) or single lever (14428W-4-CP) operating members. The product is supplied with stainless-steel braided EPDM lined flexible hose assemblies to connect the headworks to the spout outlet. Spouts incororate plastic flow straightners. Maximum working pressure 5 bar. Maximum operating temperature 60°C
Range of wall mounted, three-hole, metal, single outlet (fixed), combination tap assemblies (concealed brass body, various finishes - see model), incorporating quarter turn ceramic disc headwork with single lever, cross top or dome type operating members (see model). The spout outlet incorporates a plastic aerator (F7 & F9 prefix models only). Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of three-hole, single outlet (swivel) combination tap assembly incorporating brass body - various finishes) and quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 60°C
Range of combined bath fillers and overflow waste assemblies (plated brass covers and plastic hoses) with pop-up wastes. Maximum operating temperature 65ºC. Open outlet use only.
Range of wall mounted spouts with a brass body (various finishes, see model). The outlet incorporates a plastic aerator. Maximum operating temperature - 60°C
Range of QSL stainless-steel expansion bellows with either threaded or flanged end connections. Maximum working pressure: See models. Maximum operating temperature 99°C.
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Models ALT-ST0019 & ALT-ST0019 are supplied with a pressure gauge. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Stainless steel press fittings for use with 316L & 304 stainless steel tube incorporating EPDM ‘O’ rings. The fittings and tube are assembled using a crimping tool. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of copper and brass press-fit fittings with HNBR o-rings, for use with copper tube manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
alpex Duo XS and alpex L (PPSU & Brass) ranges of press fittings for use with alpex Duo XS (F and TH press profiles) & alpex L pipe (F press profile only). Maximum working pressure 10.0 bar. The maximum operating temperature is 95oC.
PLAS-FIT range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of copper end feed solder fittings for use with copper tube (EN1057). For above and below ground use. Maximum working pressure for sizes 8mm to 54mm is 25.0 bar. Maximum working pressure for sizes above 54mm is 16.0 bar. Maximum operating temperature 99°C.
IR sensor activated dual flush WC siphon valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. Cold water only.
Range of dual flush WC outlet valves. The valve incorporates an internal overflow and is operated via a push button assembly for either full or reduced flush. Cold Water Use
Range of urinal flushing mechanisms incorporating nylon bodies and a solenoid valve which controls the flow and is actuated via an infra-red sensor. The inlet of the solenoid valve incorporates a stainless-steel strainer. Maximum working pressure 5.0 bar. Cold water use only.
Range of wall mounted combination boilers providing domestic hot water via a heat exchanger and pressurised central heating system. The products can be supplied with a rigid or flexible filling loop or keyless filling link. The flexible and rigid filling loops incorporate a flexible hose or copper pipe, isolation valve, double check valve assembly (suitable for back flow protection against fluid category 3). The keyless filling link incorporates a CAB backflow prevention device (suitable for back flow protection against fluid category 3). The products also incorporate an expansion vessel and pressure relief valve set at 3.0 bar. Maximum working pressure of primary circuit 2.5 bar. Maximum operating temperature of primary circuit 85°C Maximum working pressure of secondary circuit 8.0 bar Maximum operating temperature of secondary circuit 60°C
Preheat accessory assembly for connection to the domestic hot water circuit of a combination boiler. Incorporates flow sensor, flow restrictor, flow silencers, pre-heat sensor and filter. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of water meters with black epoxy coated bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Page 169 of 443
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.