Tudor range of above and under sink range of electrically heated vented water heaters (cased and insulated) incorporating an angle valve on the inlet for flow control. Maximum working pressure 3.5 bar. Maximum operating temperature 75°C.
Range of in-line water meters with composite bodies, TPE gasket and NBR ‘O’-ring(s). The products have an integral plastic filter. The inlet of the in-line models includes a non-return valve. Maximum working pressure 16.0 bar. Cold water use only.
Jet range of water meters with brass blue epoxy coated bodies and EPDM rubber ‘O’-rings. Maximum working pressure16.0 bar. Maximum operating temperature 85°C.
Manifold with a brass body and 5 outlets. Maximum working pressure 15.0 bar. Maximum operating temperature 100°C.
Wall plate elbow with a brass body. Maximum operating temperature 100°C
Range of leak detection devices incorporating a DZR brass body and non-return valve (not intended for and not suitable for backflow protection). Models 3897590 & 3897690 incorporate a spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Self-closing hand spray with a stainless-steel body. The inlet incorporates a flow regulator and an approved check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum working pressure 5 bar. Max operating temperature 60°C.
Range of two, three and four pump cold water booster sets. The products incorporate a suction and discharge manifold and pumps. Maximum working pressure 10 bar. Cold water use only.
‘AMV-FB’ and ‘AMV-FE’ range of two, three and four pump cold water booster sets. The products incorporate a suction and discharge manifold, vertical multistage pumps, expansion vessel, isolation valves, pressure sensor and flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
Range of horizontal multistage close coupled centrifugal pumps incorporating stainless steel cased bodies and impellers. Maximum working pressure: See models. Cold water use only.
Range of horizontal multistage pumps with stainless steel bodies, diffuser and impellers and EPDM ‘O’-rings. The products incorporate a graphite-SiC-EPDM shaft seal. The products incorporate a drain plug. Maximum working pressure 8.5 bar. 9Maximum operating temperature 80°C.
Range of vertical (CVM) or horizontal (CHM) multistage pumps with stainless-steel bodies and stainless-steel impellers, intermediate chambers, shaft and outer sleeve and EPDM seals. Maximum working pressure: 25 Bar. Maximum working temperature: 23°C.
Range wall mounted shower outlet connectors with brass bodies, chrome finish. The outlet incorporates a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum operating pressure 10 Bar. Maximum operating temperature 70°C.
Range of overhead shower outlets, wall and ceiling mounted shower arms with (brass bodies - various finishes). The overhead shower inlet incorporates a combined NBR washer and stainless steel strainer. Maximum operating pressure 5 bar. Maximum operating temperature 85°C
Range of shower handsets and overhead showers, (plastic bodies - various finishes). The inlets incorporate a plastic flow restrictor and stainless steel strainer. Maximum operating temperature 60°C. Open outlet use only.
Range of wall mounted shower heads incorporating (chromium plated brass body) and EPDM ‘O’-rings. Maximum operating temperature 60°C
Range of wall mounted shower outlets (FT prefix models) and shower handsets (HS prefix models). The HS-BR003CP and HS-BS004CP models have brass bodies (chrome plated). The HS-AS008CP and HS-AR009CP models have plastic bodies (chrome plated). The FTS0406RCP, FTB2210RCP and HS-SR001CP models have stainless-steel bodies (chrome plated). The FTS0406RCP model is incorporates a combined NBR washer and stainless-steel strainer on the inlet and four plastic aerators on the outlet. Maximum operating temperatures: FTS0406RCP model 65°C, HS-AR009CP model 75°C, all other models 85°C.


Shower handset with a plastic body (with various finishes), stainless steel strainer and flow regulator. Maximum operating temperature of 60oC. Open outlet use only.
Chrome plated plastic shower handset incorporating a flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range shower outlets and accessories with brass bodies (various finishes). The inlet of the overhead shower outlet incorporates a stainless steel strainer. Maximum operating temperature 85°C. Open outlet use only.
Range of overhead shower outlets, (brass bodies – various finishes) incorporating NBR O rings. Maximum operating temperature: 65C
Range of overhead shower outlets with brass or stainless-steel bodies (various finishes - see model), with NBR ‘O’-rings. The inlet incorporates a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 70°C
Range of in-line Y patterned strainers with flanged ductile iron bodies (blue epoxy coated) and stainless-steel mesh strainers. The strainers also incorporate a drain plug. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
A range of ‘Y’-patterned strainers with bronze bodies incorporating a stainless-steel mesh strainer and PTFE washers. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Wall mounted bib tap with a nickel-plated brass body, chrome plated brass ball, NBR ‘O’-rings and gasket, and PTFE seats. The product incorporates a hose union outlet with an integral plastic flow straightener. Maximum working pressure 20.0 bar. Maximum operating pressure 85°C.
Draining tap with elbow shaped DZR brass body and a rising spindle headwork. Maximum working pressure 15.0 bar. Maximum operating temperature 85°C.
Pillar tap (chrome plated brass body) incorporating quarter turn ceramic disc headwork with cross top operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Self-closing combination tap assembly (chromium plated brass) with a spring-loaded headwork controlling both temperature and flow with a dome type operating member. The spout outlet incorporates a plastic flow straightener. The flexible hose inlets incorporate a combined EPDM washer and stainless-steel strainer, as well as an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of self-closing pillar taps (chrome plated brass bodies) with spring loaded headwork and dome type operating member. The spout outlet incorporates a plastic flow straightner. The products are supplied with metal backnuts and stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, self-closing bib tap, (chrome plated brass body) with spring loaded headwork and dome type operating member. The spout outlet incorporates a plastic flow straightner. The inlet incorporates a stainless steel strainer. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of black HDPE Pipe SDR 11 manufactured to ISO 4427 / DIN 8074 / EN12201. Maximum working pressure: 16 Bar. Maximum operating temperature: Cold water use only.
Range of multilayer PVC hoses. Maximum operating temperature 65°C. Open outlet use only.
Range of stainless steel or black nylon braided PEX lined flexible hose assemblies with brass end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel braided hoses, incorporating a dual layered hose consisting of a clear PE liner and black coloured EPDM outer layer. The SOG1212XXX(GLF)CS model incorporates an isolation valve. The models with compression connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel braided PEX lined flexible hose assemblies with EPDM washers and/or ‘O’-rings, and brass end connections. The 15mm compression connection incorporates an isolation valve. The models with compression connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
PVC flexible hose assembly. Maximum working pressure 10.0 Bar. Cold water use only.
Range of stainless steel braided, EPDM lined flexible hose assemblies with a variety of end connections (see models for full breakdown), including EPDM washers and ‘O’-rings where applicable. Some models are supplied with screwdriver operated isolation valves (see model list). All compression and push-fit fittings are to be used with copper pipe (manufactured to BS EN 1057). Maximum working pressure: 16 bar. Maximum operating temperature: 85°C.
Range of stainless steel interlocked shower hoses with EPDM O-rings. Maximum operating temperature 65°C. Open outlet use only.
Range of stainless steel or black nylon braided EPDM lined flexible hose assemblies with EPDM washers and/or ‘O’-rings, and brass end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Stainless steel braided or nylon braided PEX lined flexible hose assemblies with various end connections. Maximum working pressure 10.0 Bar Maximum operating temperature 85 °C.
Range of wall mounted, manually blended, shower valves, (brass bodies – various finishes). Incorporating a ceramic cartridge controlling both the flow and temperature. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed, manually operated blending valves (brass bodies - various finishes) incorporating a ceramic cartridge headwork controlling both flow and temperature and a self cancelling diverter with a lever type operating member. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of concealed manually operated blending valves with (brass bodies - various finishes), incorporating a ceramic cartridge headwork controlling the flow and temperature, a manually operated diverter to shower outlets and a lever type operating member. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.

Range of T-type thermostatic mixing valves with DZR brass bodies. Temperature is pre-set under a fixed cap. The inlet adaptors incorporate single check valve cartridges (verified by test, suitable for backflow protection against Fluid Category 2) and stainless-steel strainers. Maximum working pressure 10.0 Bar. Maximum operating temperature 85.0°C.
Range of T-type thermostatic mixing valves with DZR brass bodies. Temperature is pre-set under a fixed cap. The inlet adaptors incorporate single check valve cartridges (verified by test, suitable for backflow protection against Fluid Category 2) and stainless-steel strainers. The inlet adaptors for models DT400MX15CP & DT400MX22CP are 90° elbows instead of straight adaptors and incorporate additional integral spherical valves. Maximum working pressure 10.0 Bar. Maximum operating temperature 85.0°C.
Range of wall mounted concealed electronically controlled thermostatic shower mixers, incorporating plastic solenoid valves to control the flow to various outlets activated via a remote actuator. The temperature is controlled via two transducers housed within the concealed box. The products incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating pressure: 6.0 bar. Maximum operating temperature: 65°C
Range of wall mounted bar type thermostatic shower valves (brass bodies – various finishes) incorporating ceramic disc headwork which controls the flow to 2 outlets with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with dome type operating member which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an optional flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of wall mounted thermostatic blending valves, (brass bodies - various finishes) incorporating a single sequential headwork, controlling the flow and the temperature and a manually operated diverter to the shower outlets The inlet on the shower handset incorporates an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of lugged and wafer type butterfly valves with blue epoxy coated bodies, incorporating EPDM rubber ‘O’-rings and seat, and either a bronze (AB2), stainless steel (CF8 & CF8M) or blue epoxy coated or nickel plated, ductile iron (DI) disc. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Page 155 of 236
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.