A deck mounted two hole, single outlet (fixed) combination tap assembly, with a brass body (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The product is supplied with metal back nuts and plastic aerators. Maximum working pressure: 5.0 bar. Maximum operating temperature: 60°C.
Range of two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Three-hole, single outlet (fixed) combination tap assembly (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided PEX lined flexible hose assemblies. The product is supplied with a flow regulator and lever type pop up waste, not verified by test. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted three-hole, single outlet (fixed) combination tap assemblies (chromium brass bodies). Incorporating quarter turn ceramic disc headworks and lever type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 70.0°C
Range of wall mounted spouts (plastic body). The outlet incorporates a plastic flow straightener. This product has not been tested or approved for claims of sterile properties made by the approval holder. Maximum operating temperature 60.0°C.
Wall mounted spout outlet (Chrome finish). The spout outlet incorporates a plastic aerator. Open outlet use only. Maximum operating temperature 60.0°C
Floor standing spout outlet (chromium plated brass) to be used with concealed body 3594597090. Open outlet
Range of in-line water filters with plastic bodies. Maximum working pressure 8.0 bar. Cold water use only.
Range of carbon filter cartridges. Cold water use only.
Range of press fittings (brass bodies - various finishes) with stainless steel press (‘TH’ profile) collars and EPDM O-rings for use with “VMA” range of PEX/AL/PEX multilayer pipe (for press fitting connections and compression for adaptor fittings only) or copper pipe manufactured to EN1057 (compression connections). Maximum operating temperature: 95°C. Maximum operating pressure: 10 bar.
Range of stainless steel press fittings to be used with stainless steel pipes. Connection is achieved via M profile press jaws. For above ground and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Atlas range of fusion welded, PP-RCT fittings for use with Atlas PP-RCTGF pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of copper solder ring fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper solder ring fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of plastic, push-fit fittings (wall plate elbow, equal elbow, end stop, pipe insert, equal straight and equal tee) for use with MDPE pipe (manufactured to BS EN 12201), for above and below ground use. Copper adaptors are for use with PB pipe (manufactured to BS7291-2), PEX pipe (manufactured to BS7291-3) or Copper pipes (manufactured to BS EN 1057) and are for above ground use only. Maximum working pressure 16.0 bar. Cold water use only.
‘Universal Transition Coupling (UTC)’ range of plastic compression fittings for use with the following pipe types and sizes: Stainless steel (manufactured to ASTM A554/ BS EN 10312): ¾”, 1” & 1¼”. Galvanised (EN 10255): ¾”, 1”, 1¼”, 1½” & 2”. Copper (BS EN 1057): 15mm, 22mm & 28mm. PVC (BS EN 1452): 20mm & 2”. ABS (BS 5391-1): 20mm, 25mm & 32mm. PE80 & PE100 pipe (to BS EN 12201): 20mm, 25mm, 32mm, 50mm & 63mm. For use above and below ground. Maximum working pressure 12.5 bar. Cold water use only.
Range of copper end feed fittings for use with copper tube to EN 1057. For above and below ground use. Maximum working pressure: 6mm-54mm 16.0bar, 64mm-108mm 10.0bar. Maximum operating temperature 85°C
Range of water meters with blue epoxy coated cast iron bodies. Maximum working pressure 16.0 Bar Maximum operating temperature 65.0°C
Range of inline water meters with brass bodies (blue or red epoxy coating). The inlet incorporates a plastic strainer. Maximum working pressure 16.0 Bar. Maximum operating temperature 85.0°C.
Range of water meters with brass bodies, plastic turbines and EPDM washers. Inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of water meters with blue epoxy coated ductile iron bodies, plastic measurement chambers and vanes and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with brass bodies and plastic turbines. The inlet incorporates a plastic filter. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
‘Altair V4’ range of in-line and manifold volumetric water meters with brass or plastic bodies (see models), the products can be provided with a plastic strainer. Maximum working pressure 16.0 bar. Cold water use only.
Range of inline water meters with either brass or plastic bodies incorporating EPDM ‘O’-rings and can be provided with a plastic strainer. Maximum working pressure 16 Bar Cold water use.
Range of wall brackets (brass bodies – various finishes). Open outlet use only Maximum working temperature 85°C
Range of flexible joints incorporating an EPDM (inner & outer) joint with a steel reinforcing ring and two carbon steel flanges. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.
Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of accumulators. The brass vessel connector of the ACC-060-TNK, ACC-120-TNK and ACC-180-TNK models incorporates a plastic flow regulator. Maximum working pressure 8.6 bar. Cold water use only.
‘Vari RS’ range of single, twin & triple cold water booster sets. The products incorporate one or more pumps, expansion vessels, isolation valves and non-return valves (not suitable for backflow protection). The twin and triple models include a suction and discharge manifold. Maximum working pressures - see model. Cold water use only.
Range of pumps with plastic bodies. Maximum working pressures: 41.007.400 model: 0.28 bar, 41.008.400 model: 0.38 bar. Maximum operating temperature 96°C
Range of single, twin & triple cold water booster sets. The products incorporate one or more pumps, expansion vessels, isolation valves and non-return valves (not suitable for backflow protection). The twin and triple models include a suction and discharge manifold. Maximum working pressures - see model. Cold water use only.
Shower handset with a stainless-steel body (various finishes - see model) and silicone nozzles. The inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 65°C.
Range of overhead shower and shower handsets with (brass or plastic bodies – various finishes), incorporating a stainless-steel strainer on the inlets. Open outlet use only Maximum operating temperature – 85°C.
Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
---|---|---|---|---|---|---|---|---|---|---|---|
VR1000 | Chrome | 15mm | 5 bar | 60 °C | Bristan | Body | No | Not applicable | Metal Backnuts | Not Applicable | Fixed Head, |
Range of shower kits comprising of a shower hose, handset and riser rail assemblies. Models (AOSRCPUK & AOSRBK) are supplied with a round or square wall outlet. Maximum operating temperature 60°C. Open outlet use only.
Range of shower sets incorporating either a wall elbow or wall elbow with hand shower, (chromium plated brass). The shower holder incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only Maximum operating temperature 60.0°C
Range of In-line Y patterned strainer with cast iron bodies (blue epoxy coated) and stainless-steel screens. Maximum working pressure 16.0 Bar. Maximum operating temperature 85.0°C.
Range of in-line Y patterned strainers with bronze bodies and a stainless-steel mesh strainer. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of In-line Y patterned strainers with ductle iron bodies (blue epoxy powder coated) and stainless-steel mesh. Maximum working pressure: 16 Bar Maximum operating temperature: 85 °C
Range of in-line Y patterned strainers with bronze bodies and a stainless-steel mesh strainer. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of in-line Y patterned strainers with bronze bodies and a stainless-steel mesh strainer. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of in-line Y patterned strainers with bronze bodies and a stainless-steel mesh strainer. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of Y patterned strainers with a brass body. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chromium plated brass) with quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic flow straightener, and the product is supplied with a metal back nut. Maximum working pressure 16.0 Bar Maximum operating temperature 85.0°C
Pillar tap (chromium plated brass) with quarter turn ceramic disc headworks and a single lever operating member. The spout outlet incorporates a plastic flow straightener, and the product is supplied with a metal back nut. Maximum working pressure 16.0 Bar Maximum operating temperature 85.0°C
Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
---|---|---|---|---|---|---|---|---|---|---|---|
MEFC-PAK | Chrome | 15mm | 5.0 bar | 60 °C | Bristan | Fixed Head | No | Self closing | Not Applicable | Not Applicable |
Range of PVC plastic shower hoses with black and silver corrugated outer, with EPDM washers. Maximum operating temperature 60°C.
Multi-layer PVC shower hoses with silver coating, brass end connections, EPDM gasket and NBR ‘O’-ring. Open outlet use only. Maximum operating temperature 65°C
Range of shower hoses with PVC outer (various finishes) and TPE liner. Maximum operating temperature 65.0°C. Open outlet use only.
Range of PVC outer layer shower hoses with a PVC internal layer and EPDM washers. Open outlet use only. Maximum operating temperature:60C
Page 149 of 171
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.