Section Code 0685 : Tap(s) with a non-touch method of flow control incorporating temperature control.
Back To Directory SectionsRange of deck mounted, single hole, single outlet (fixed) electronically controlled combination tap assemblies (black or chrome plated brass). The flow is controlled via solenoid valve which is actuated by an infra-red sensor and the temperature is controlled independently via a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass) bodies. The flow is controlled via a solenoid valve activated via an infra-red sensor. The temperature is controlled independently via a thermostatic cartridge. The products incorporate approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets incorporate a stainless-steel strainer. The products are supplied with spherical valves for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Page of 1
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.