Range of shower outlets comprising of shower heads all incorporating stainless-steel strainer washers (plastic bodies-various finishes) and handheld showers (plastic bodies - various finishes). Maximum operating temperature 75°C.
Range of overhead shower and shower handsets with (brass or plastic bodies – various finishes), incorporating a stainless-steel strainer on the inlets. Open outlet use only Maximum operating temperature – 85°C.
Range of shower arms, (stainless steel bodies – various finishes). Open outlet use only. Maximum operating temperature - 85°C
Range of shower handsets with (plastic bodies - various finishes) incorporating a plastic flow restrictor in the inlet. Open Outlet use only Maximum operating temperature 60.0°C
Range of Y pattern strainers having either brass (899ST range) or bronze (900 range) bodies and PTFE seat washers. Maximum working pressure 20.0 Bar (Model 900), Maximum working pressure 32.0 Bar (Model 899ST). Maximum operating temperature 100.0°C.
Range of ‘Y’-pattern strainers with blue epoxy coated ductile iron bodies and a stainless-steel screen. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Flow sensor with a plastic and brass body. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of drain valves with a brass bodies, spindle and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of wall mounted hose union bib taps incorporating a rising spindle headwork with a T - handle operating member. Model 13.20202.G15.CP5R-8511 has a DZR brass body, all other models have a brass body. Model 13.20252.G15.CP5R-8510 incorporates a lockshield device at the base of the operating stem. The spout outlets incorporate a hose union connector. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Wall mounted hose union tap brass body incorporating a non-rising spindle headwork with a lock shield and removable butterfly handle operating member. The spout outlet incorporates a hose union connector. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps with (brass bodies - various finishes) incorporating a quarter turn ceramic disc headwork with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10 bar. Maximum operating temperature 60°C
Range of pillar taps (brass bodies – various finishes) incorporating a quarter turn ceramic disc headwork with a single lever or cross top operating member. The product is supplied with metal backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C.
Range of pillar taps, incorporating a non-rising spindle headwork with cross top or dome type operating members. The spout outlet incorporates a plastic flow straightener, and the product is supplied with metal back nuts. All taps are supplied with an optional flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of stainless steel inter-locked shower hoses incorporating PVC linings in various finishes. Maximum operating temperature 65°C.
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection). Also supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Also supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of Compress 5800i AW vertical cased and insulated indirect unvented stainless steel hot water storage cylinders fitted with a Caleffi 309508 CST temperature and pressure relief valve set at 10 bar & 90°C, and supplied with a Caleffi inlet control group consisting of in-line pressure reducing valve (set at 3.5 bar) and pressure relief valve (set at 6 bar) and incorporates an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2). The cyclinders also supplied with an 18L expansion vessel and Intatec filling loop assembley (FL12041510). Maximum working pressure 10 bar. Maximum operating temperature 80°C.
Range of single/double orifice air venting valves with blue epoxy coated ductile iron bodies, and a stainless-steel float ball. Incorporating EPDM washers. Maximum working pressure 16.0 Bar. Maximum operating temperature 80.0°C.
Range of air venting valves with blue epoxy coated ductile iron bodies and a plastic float. Maximum working pressure16.0 bar. Cold water use only.
Range of wall mounted concealed, manual blending valves with a brass body (various finishes), incorporating a ceramic cartridge headwork with a single lever type operating member. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted bar type shower mixing valve (brass body, various finishes - see model). The product incorporates a ceramic cartridge headwork with a single lever operating member. The hose outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of T-type thermostatic blending valves with nickel plated brass bodies and EPDM ‘O’-rings. The inlet and outlet incorporate an approved check valve cartridge ((verified by test - suitable for backflow protection against fluid category 2). Models with compression ends are to be used with copper pipe EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of concealed, wall mounted thermostatic blending valves with brass bodies (chromium plated trim sets). The products consist of a two-way diverter and a thermostatic cartridge controlling the temperature. All models incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5 bar. Maximum operating temperature 60°C.
Range of T-type thermostatic blending valves with DZR brass bodies. Maximum working pressure 14.0 bar. Maximum operating temperature 90°C.
Range of T-type thermostatic mixing valves with DZR brass bodies. Maximum working pressure 14.0 bar. Maximum operating temperature 100°C.
Range of wall mounted thermostatic bar shower mixers (chrome plated brass bodies), incorporating ceramic disc diverter valve controlling the flow with a cubed type operating member. The temperature is controlled independently via a thermostatic cartridge with a cubed type operating member that incorporates a manual override button. The inlets incorporate stainless-steel strainer washers and approved single check valve cartridges (however, the complete product has not been fully tested to demonstrate that it provides backflow protection). Products are supplied with shower handset, shower hose, overhead shower and riser rail assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted concealed thermostatic shower valves (brass bodies – various finishes) incorporating a manual diverter to shower outlets and quarter turn ceramic disc headwork controlling the flow with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with dome type operating member. Both inlets incorporate approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 75°C
Range of wall mounted bar type thermostatic shower valves (brass bodies – various finishes) incorporating quarter turn ceramic disc headwork which controls the flow with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with dome type operating member which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an optional flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C
Range of wall mounted bar type thermostatic shower valves (brass bodies – various finishes) incorporating ceramic disc headwork which controls the flow to 2 outlets with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with dome type operating member which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an optional flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
Range of wall mounted bar type thermostatic shower valves (brass bodies – various finishes) incorporating quarter turn ceramic disc headwork which controls the flow with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with dome type operating member which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an optional flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C
Combined temperature and pressure relief valves pre-set at 7.0 bar with a DZR brass body. Maximum operating temperature 90°C.
Range of pilot operated flow control valves with (blue or red/brown) epoxy coated stainless steel bodies and EPDM ‘O’-rings. Auxiliary components include stainless steel tube with fittings, a strainer, spherical valves, needle valve and restriction orifice. Maximum working pressure 16.0 Bar Maximum operating temperature 65 °C.

Range of eccentric plug valves with blue epoxy coated ductile iron bodies, PTFE washers a stainless steel plug which is fully encapsulated with EPDM. Maximum working pressure 16 Bar. Maximum operating temperature 80°C.
Range of spring-loaded non-return valves with stainless steel bodies. Maximum working pressure 24.5 bar. Maximum operating temperature 85°C
Range of swing gate, non-return valves with (blue, black or red epoxy powder coated) ductile iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of swing gate, non-return valves with (blue or red epoxy powder coated) ductile iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of swing gate non-return valves with bronze bodies, bonnets & PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of in-line, manually adjustable pressure reducing valves with nickel plated DZR brass body. Maximum inlet supply pressure 25 bar. Maximum operating temperature 80°C
533 series of in-line, manually adjustable pressure reducing valves (DZR brass or brushed chrome plated DZR brass bodies) incorporating a stainless-steel strainer. All models except 533159 are supplied with a pressure gauge. Models with compression connection are for use with copper tube (manufactured to BS EN 1057). Maximum supply pressure 16.0 bar. Outlet pressures between 1.0 – 6.0 bar. Maximum operating temperature 40°C.
Range of adjustable pressure reducing valves with stainless steel bodies and EPDM ‘O’-rings and diaphragm. These products are available with the following adjustable outlet pressures: between 1.0 and 6.0 bar (model REF-150-S is between 1.2 and 6 bar), between 4.0 and 10.0 bar or between 8.0 and 13.0 bar. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of adjustable, in-line pressure reducing valves with DZR brass bodies, incorporating a spring loaded EPDM diaphragm and a gauge port. The products incorporate an integral stainless steel strainer. The outlet pressure range is adjustable between 1.0 and 6.0 bar. Maximum inlet supply pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 40°C
Range of lever operated spherical valves with nickel plated brass bodies, chromium plated brass ball, PTFE seats and a drain valve. Maximum working pressure 25.0 Bar Maximum operating temperature 100.0°C
Range of spherical valves with nickel plated brass bodies, incorporating a chrome plated brass ball, PTFE seats with either lever, butterfly or T operating members. Maximum working pressure 20.0 bar. Maximum operating temperature 85˚C
Range of spherical valves with a brass body and PTFE seats. The products incorporate a lever or butterfly type handles. Maximum working pressure 30.0 bar. Maximum operating temperature 85°C.
Range of resilient seated gate valves with a blue epoxy coated ductile iron body and a ductile iron gate/wedge which is fully encapsulated with EPDM. Maximum working pressure 16.0 Bar. Maximum operating temperature 80.0°C.
Range of hand wheel operated or key operated gate valves with blue epoxy coated ductile iron bodies, ductile iron wedge encapsulated in EPDM. Models HY-002A & HY-002B incorporate brass valve seats Maximum working pressure 16.0 Bar Maximum operating temperature 65.0°C
Range of gate valves with a brass body and wedge, brass spindle, fibre/NBR gasket and PTFE stem gasket. The valves incorporate a non-rising stem with a hand wheel operating member. Maximum operating pressure 16 bar. Maximum operating temperature 100°C.
Page 149 of 236
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.