Range of ceramic cartridge headwork incorporating plastic bodies (various finishes) and NBR ‘O’-rings. The products are intended for insertion into specifically dimensioned tap assemblies. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The product incorporates a pull-out spout outlet with a plastic aerator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a pull-out spray with plastic aerator. The cold Inlet incorporates approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet can incorporate either a plastic flow straightener or a plastic aerator. When supplied with a plastic flow straightener there is a combined EPDM washer and stainless steel strainer behind it. The products are available either as a version with a pop-up waste or one with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Single-hole, single outlet, (fixed) combination tap assembly with brass bodies (chrome plated), incorporating non-rising spindle headworks with cross top operating members. The spout incorporates a plastic flow straighter this product is also supplied with an additional aerator. Model CL4 is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of wall mounted, electronically operated combination tap assemblies (various finishes, see model ) incorporating a solenoid valve controlling the flow which is actuated via in infrared sensor. The spout outlets incorporate a aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headworks, and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, single hole, single outlet (fixed) combination tap assemblies with chromium plated, DZR brass bodies. The products incorporate a single sequential headwork with a single lever operating member or a push button. The spout outlets incorporate a plastic flow straightener. The inlets incorporate an approved check valve cartridge however, the complete products have not been fully tested to demonstrate it provides backflow protection. Products are supplied with metal back nuts. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies incorporating chromium plated or stainless steel plated brass bodies, ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Some models are supplied with a click type waste (fully tested). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass bodies), incorporating ceramic cartridge headworks with single lever operating members incorporates plastic aerators supplied with a pop-up waste. Maximum working Pressure 10.0 bar. Maximum operating temperature 65ºC.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork controlling the hot and cold flow. The 63264 model also incorporates a push to open, push to close, ‘detent’ headwork intended to control a filtered water supply. The spout outlets incorporate a plastic aerator. The cold water inlet hose is supplied with a chrome plated brass adaptor (½” BSP (F) x ½” BSP (M)) incorporating a check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2). The 63264 model is also supplied with brass tee piece (½” BSP (F) x ½” BSP (M) x spigot (for quick connector)) for connection prior to the brass adaptor containing the check valve cartridge. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole single outlet (swivel) combination tap assmeblies with quarter turn ceramic disc headworks and single lever operating members. The outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Deck mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), Models M33136 & M1006 incorporate a quarter turn ceramic disc headwork with single lever operating members. Models M4306, M4306E & M4306F incorporate a non rising spindle headwork with dome type operating members. Model M4306G incorporate a non rising spindle headwork with cross top operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. . Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of combined bath fillers and overflow waste assemblies with plastic bodies (various finishes). The outlet incorporates a plastic aerator and the product is supplied with a cable operated pop-up waste. Maximum operating temperature 60°C.
Range of Eco Duo copper press fittings with EPDM ‘O’-rings for use with Eco-Duo copper tube. The joints are achieved by means of a crimping tool. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Aquaflow polypropylene bodied compression fittings with EPDM ‘O’-rings for use with Elysee PE80 blue pipes. The fittings are supplied with a pipe liner. Above and below ground use. Maximum working pressure 12.5 bar. Cold water use only.
Range of Kelox Protec brass & PPSU push fit connection fittings with EPDM seal rings for use with Kelox multilayer composite pipe (PE-RT type ll/AL/PE-RT type ll). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of polypropylene push-fit fittings and inserts for use with MDPE pipe (manufactured to BS EN 12201). For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Range of polypropylene push-fit fittings with inserts for use with MDPE Pipe (manufactured to BS EN 12201-2) on one side of the fitting and PB (BS 7291), PEX (BS 7291) or Copper (BS EN 1057) on the other. Models UTS147-DB, UTS197-DB & UTS251-DB are for above and below ground use. All other models are for above ground use only. Maximum working pressure when using 20mm pipe is 16.0 bar. Maximum working pressure when using 25mm & 32mm pipe is 12.5 bar. Cold water use only.
Range of brass press fittings with EPDM ‘O’-rings for use with EN ISO 21003 pipe. Maximum working pressure 10.0 bar. For cold water use only.
Range of WC dual flush outlet valves with silicon seals and ABS bodies. The SKY005, SKY015 & SKY020 valves are operated via a push button assembly for either full or reduced flush. The SKY030 model may be operated via a push button assembly or a lever for either full or reduced flush. The valves incorporate an internal overflow. For cold water use only.
WC dual flush drop valve with plastic body silicone and rubber seal. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold Water Use Only.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Range of waste water heat recovery systems incorporating a twin wall copper coil (7773414 models) or stainless steel (7771332 models). Maximum working pressure 10.0 bar. Cold water use only.
Range of gas fired water heaters incorporating stainless steel strainers on the inlets. Maximum working pressure 10.0 Bar Maximum working temperature 85˚C
Range of ice making machines which incorporate a solenoid valve to control the flow. Maximum working pressure 5.0 bar. Cold water use only.
Range of commercial ice making machines which incorporate a solenoid valve controlling the flow. Maximum working pressure 7.8 bar. Cold water use only.
Range of rotating piston, volumetric in-line water meters with brass bodies. Maximum working pressure 16.0 bar. Cold water use only.
Water meter incorporating a brass inner body, a plastic outer body and liquid silicone ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of pressure transmitters with stainless steel bodies. Maximum working pressures: DST-P140 model 25.0 bar, all other models 50.0 bar. Maximum operating temperature 90°C.
Vola 200M separate outlet socket with brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Water hammer arrestor with brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of eccentric hemisphere valves incorporating blue epoxy coated carbon steel bodies and discs, EPDM seat and a handwheel operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Wall mounted outlet with detachable shower hose connector (42037UK model) and wall mounted shower outlet (42018UK model). The 42018UK model is supplied with an optional, detachable shower hose connector assembly which incorporates an integral plastic flow regulator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model 42037UK has a maximum operating temperature of 80°C. Model 42018UK has a maximum operating temperature of 60°C.
Range of circulating pumps, with plastic or stainless steel bodies (cast EN 1.4308 or plate EN 1.4301) and a plastic impeller. Maximum working pressure 10.0 bar (stainless steel bodied pumps), 3.0 bar (plastic bodied pumps). Maximum operating temperature 95°C.
Range of single stage circulating pumps with plastic impellers and stainless steel housing, (red external coating - all models, and from July 2023 a yellow external coating on the 1½" model with 130mm port length). From December 2023 the UPS25 prefix models can be supplied with EPDM inlet/outlet gaskets and the UPS32 prefix models can be supplied with fibre/NBR inlet/outlet gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C (s/steel plate EN 1.4301/1.4401 models) or 99°C (s/steel cast EN 1.4308 models).
Range of booster sets with a stainless steel manifold system connecting 2 or 3 wholesome water pumps (For 2HELIX & 3HELIX models only). The set also includes spherical valves, and a non-return valve Maximum working pressure: 10.0 Bar Maximum operating temperature: 40°C
Range of single stage centrifugal pumps with bronze housings or plastic housings (see model) and plastic impellers. Maximum working pressure 6.0 bar (UP(S)(O) 15-XX CES87 130 model only), 10.0 bar (all other models). Maximum operating temperature 95°C.
Range of shower handsets and shower heads with chrome plated bodies and built in flow restrictors. Maximum operating temperature 60°C.
Range of wall mounted handshower, hose and elbow sets with metal bodies (various finishes), incorporating an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Handsets incorporate an approved check valve cartridge , however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Range of shower kits incorporating a chrome plated plastic shower handset, shower hose and riser rail. Maximum operating temperature 65°C.
Range of shower handsets and overhead showers with metal chromium plated bodies with. Models 20123 and 15185 are fitted with check valves at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Model 20127 is supplied with a flexable hose connection. Maximum operating temperature 60°C.
Shower kit consisting of a shower hose, handset and raiser rail (EKIT01/A model) or shower handset only (AIR1HSCPWHUK model). Maximum operating temperature 60°C.
Range of shower handsets and shower heads with chromium plated ABS bodies. Maximum operating temperature 75°C.
Range of atmospheric steaming ovens having a 25 litre, 70 litres or two 25 litres capacity chambers. The water supply is controlled via a solenoid valve and incorporates a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10.0 bar & maximum operating temperature 23°C.
Range of pillar taps with brass bodies (chrome plated), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener or aerator. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating pressure 85°C.
Page 15 of 204
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.