Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic cartridge headworks with dome type operating member. The inlet incorporates a flow restrictor and the spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members or non-rising spindle headworks with cross top operating members (model CR26 & CR26/501). The spout outlet incorporates a plastic flow straightener (models CR26 & CR26/501 do not incorporate a flow straightener). The products are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks with single lever, dome or cross top operating members and manual diverters to shower outlets. This approval includes a hose, handset and wall bracket and the products are supplied with plastic backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of deck Mounted bar type thermostatic combination tap assemblies (chromium plated brass), incorporating a ½ turn ceramic disc headwork controlling the flow with either dome type (AR2 THBSM C & BWY AR2 THBSM C) or single lever (AR2 THLBSM C) operating members. The temperature is controlled independently via a thermostatic cartridge with either dome type (AR2 THBSM C & BWY AR2 THBSM C) or single lever (AR2 THLBSM C) operating members incorporating a manual override button. The product also incorporates a manual diverter between the spout outlet and shower outlet. The inlets incorporate a stainless steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a stainless steel strainer and a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted two-hole, single outlet (fixed) bath shower mixers with brass bodies (various finishes), incorporating a manual diverter controlling and diverting the flow between the spout outlet and an overhead shower. Temperature is controlled independently via a thermostatic cartridge with dome type operating member with manual override button. The spout outlets incorporate a plastic aerator. Each inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener and the product is supplied with a shower hose, shower handset and metal backnuts Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with dome type operating members, the temperature is controlled independently via a thermostatic cartridge with single lever operating members with a manual override button and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. Inlets incorporate stainless steel strainers approved check valve cartridges, (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of wall mounted two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headworks with single lever operating member and self-cancelling diverter to shower outlet. The inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet, swivel combination tap assembly (chromium plated brass) incorporating ¼ turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60 °C.
Range of concealed wall mounted bath shower mixers (brass body) incorporating a manual diverter to bath or shower handset. Flow is controlled by cartridge headworks using single lever type or dome operating members. Temperature is independently controlled via a single lever or dome type operating member incorporating a manual override button. Manual diverter is also controlled by single lever or dome operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of standpipes for bath/showers with a brass body (various finishes, see model). The standpipes incorporate an approved flexible hose. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of spout outlets incorporating brass bodies and NBR ‘O’-rings. The spout outlets incorporate a plastic flow straightener. Models AX-SIR-140/RO/DIV and AX-BOK-140/SQ/DIV incorporate a self-cancelling diverter. Maximum operating temperature 60°C.
`Wellmate` range of expansion vessels with plastic bodies and rubber diaphragms Maximum working pressure 8.6 Bar, cold water use only.
‘Copper press fittings - M Profile’ range of press fittings with a brass body and EPDM ‘O’-rings for use with copper pipe manufactured to EN1057:2006 +A1:2010 seamless round copper tube R250. Joints are achieved using a specialist press fitting tool. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
“Plimat PVC-U Fittings BS Inch and PVC-U Fittings Threaded” range of PVC-U solvent cement or threaded fittings for use with “Plimat PVC-U BS inch pipe” (manufactured to EN1452-2). Maximum working pressure 15.0 bar for solvent cement connections and 10.0 bar for fittings that only include/also include a threaded connection. Cold water use only.
'ALTOPOLY PB pipe'. Grey coloured, extruded multi-layered pipe consisting of a polybutylene inner and outer layer and a dark grey coloured EVOH middle barrier layer and 'ALTOPOLY EVOH PEX Pipe'. Extruded, multi-layered pipe consisting of a white coloured PEX inner, blue coloured EVOH middle layer and white coloured PEX outer. For use with SNC Corporation ‘Twistloc’ push-fit fittings covered by WRAS approval 1904906. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Uponor S-Press press fittings, Uni-X & Uni-C compression fittings for use with Uponor MLC pipe. Maximum working pressure 10.0 bar, maximum operating temperature 70°C.
‘CB ISR’ range of capillary fittings with internal solder rings, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
Range of copper and bronze capillary brazed fittings for use with copper pipe manufactured to EN1057:2006 +A1:2010. Maximum pressure 10.0 Bar (54mm up to and including 108mm) Maximum pressure 2.0 Bar (Over 108mm up to and including 159mm) Maximum operating temperature 100°C.
Range of compression fittings with polypropylene bodies, nuts, acetal grip rings, EPDM ‘O’-rings and plastic pipe liners for use with MDPE pipe manufactured to BS EN 12201. For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
“Plimat ABS Fittings BS Inch and ABS Adaptor Fittings” range of ABS solvent cement or threaded fittings for use with “Plimat ABS pipe”. Maximum working pressure: 15.0 bar (fittings with ½” - 4” solvent cement connections), 9.0 bar (fittings with 5” or 6” solvent cement connections, with or without threaded connecitons), and 10.0 bar (fittings with threaded connections and ½” - 4” solvent cement connections). Cold water and above ground use only.
Range of PSU, POM & DZR brass pushfit fittings for use with PE-x pipe (manufactured to BS7291-3), PB pipe (manufactured to BS7291-2) & copper pipe. Maximum working pressure 10.0 bar @ 65°C (PSU & DZR Brass Fittings). Open outlet use only @ 20°C (POM Fittings).
Range of press fittings incorporating copper or copper alloy bodies and EPDM O’-rings for use with copper tube to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of floor standing commercial glass washers incorporating a solenoid valve controlling the flow. The product is supplied with a double check valve assembly (suitable for backflow protection against fluid category 3). Maximum working pressure 4.0 Bar. Maximum operating temperature 60°C.
Range of indirect heat interface units providing heating and instantaneous hot water. The hot water and space heating is provided via two separate plate heat exchangers. The space heating circuit incorporates an expansion vessel and expansion relief valve (set @ 3.0 bar). The primary circuit only is supplied with isolation valves on the flow and return. Maximum working pressure primary 16.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water (DHW) 10.0 bar. Maximum operating temperature primary 75°C. Maximum operating temperature space heating 85°C. Maximum operating temperature secondary hot water (DHW) 65°C.
Range of stainless-steel plate heat exchangers with copper brazing. Maximum working pressure 30.0 Bar. Maximum operating temperature 100°C.
Range of copper brazed stainless-steel heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.
Range of stainless steel, copper brazed plate type heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.
Range of water meters with plastic bodies and EPDM ‘O’-rings. The inlets incorporate a plastic strainer. Maximum working pressure 10.0 bar. Cold water use only.
Range of shock arrestors with carbon steel or stainless steel bodies (available in various external surface finishes) incorporating Bromobutyl (BIIR) membranes. Maximum working pressure 10.0 bar. Cold water use only.
Range of shock arrestors with stainless steel bodies incorporating Bromobutyl (BIIR) membranes. Maximum working pressure 10.0 bar. Cold water use only.
Air break to drain, incorporating brass bodies with a grey epoxy powder coating. Maximum operating temperature 60°C.
Impeller with plastic body for insertion into specifically dimensioned bores. Maximum operating temperature 70°C.
Wall mounted chrome plated brass elbow fitting. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Hygienic flush box providing a timed flush facility. The supply is via a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection, flow sensor, spherical ball valve and strainer. The products incorporate a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The units have multiple interface user functions for timed flush, wireless technology and data storage. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Maincor Manifold having a brushed chrome plated body with 2 ,3 or 4 ports each with an isolation valve with red or blue indicators for hot and cold feeds. Supplied with a blanking plug and nut. Maximum working pressure 6.0 bar. Maximum operating temperature 75°C.
Pent-A-Boost domestic break tank and booster set incorporating a single or dual pump stage pump set assembly and break cistern (incorporating an AG air gap arrangement). Inlet level sensors control the water supply via solenoid valves with inline strainers fitted (see manufacturers data sheet for optional arrangements). The unit also incorporates an expansion vessel. Flow from the break tank is via a single check valve suitable for fluid category 2 to a booster pump arrangement (see manufacturers data sheet for optional arrangements). Maximum working pressure 10 bar. Cold water use only.
“Yonos PARA Z15 and Yonos PARA Z25 ” range of circulation pumps incorporating brass bodies, plastic impellers and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of single and twin ended shower booster pumps with plastic bodies and plastic impellers. The inlets/outlets incorporate stainless steel braided EPDM lined flexible hose assemblies with isolation valves and stainless steel strainers. The outlets incorporate approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. The Universal Twin models incorporate an expansion vessel. Maximum working pressure (See model). Maximum operating temperature 60°C.
Range of shower handsets incorporating ABS bodies (chrome plated), EPDM seals and ‘O’-rings. Maximum operating temperature 65°C.
Wall mounted vandal resistant shower head with (chrome plated brass finish). The inlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet incorporates a plastic aerator. Open outlet use only. Maximum operating temperature 60°C.
A range of shower handsets with chromium plated plastic bodies and a plastic strainer and flow regulator in the inlet. Models may incorporate dark grey alternative shower plate. Maximum operating temperature 85°C.
Overhead, ceiling mounted shower outlet with chromium plated brass body (various finishes). Maximum operating temperature 60°C.
Shower handset incorporating a plastic body (chrome plated), brass wall connector (chrome plated) and shower hose. The inlet to the shower and wall connector incorporates approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of over head shower outlets incorporating brass bodies and an adjustable ball joint. The inlet incorporates a combined NBR washer and stainless-steel filter. Maximum operating temperature 60°C.
Range of in-line `Y` pattern strainers incorporating DZR brass bodies, stainless steel mesh strainers and white PTFE gaskets. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of in-line `Y`-patterned strainers with either brass or DZR brass bodies (see model) incorporating a stainless steel mesh strainer and a PTFE washer. Maximum working pressure 25.0 Bar. Maximum operating temperature 99.0°C
Page 13 of 222
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.