Range of single hole, single outlet (swivel), pull down, combination tap assemblies (chrome plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spout outlet is a handspray mechanism that incorporates a plastic aerator and a button to divert between the aerator and the spray function. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Range of single hole, single outlet (swivel), pull down, combination tap assemblies (chrome plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spout outlet is a handspray mechanism that incorporates a plastic aerator and a button to divert between the aerator and the spray function. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Single hole, single outlet (swivel) combination tap assembly (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. This product is supplied with a click type pop up waste. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Two-hole, single outlet fixed combination tap assembly (chrome plated brass body) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two-hole, single outlet fixed combination tap assemblies, incorporating quarter turn ceramic disc headworks with single lever headworks. The spout outlet incorporates a plastic aerator. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 60°C
Range of two hole, single outlet fixed combination tap assemblies (brass bodies – various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightner. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of two hole, single outlet fixed combination tap assemblies (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic aerators. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies, (brass bodies, various finishes - see model), incorporating a ceramic cartridge headworks with either a single lever operating member or dome type operating member (F9482A-X model only). Thee spout outlet incorporates a plastic aerator (except model F8122A). Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
A range of two-hole, single outlet, fixed, combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to a shower outlet. The spout outlet incorporates plastic aerators or flow straightener and is supplied with metal backnuts. The products are supplied with a shower hose, handsets and metal backnuts. Maximum working pressure 10 bar.
Range of deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a half-turn ceramic disc headwork, both controlling the flow and manually diverting the flow to a shower outlet connection. Temperature is controlled independently via a thermostatic cartridge. The spout outlet incorporates a plastic aerator. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and a manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. Products are supplied with a shower hose and handset and plastic backnuts. Maximum working pressure 6.0 Bar. Maximum operating temperature 60°C.
Range of deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a half-turn ceramic disc headwork, both controlling the flow and manually diverting the flow to a shower outlet connection. Temperature is controlled independently via a thermostatic cartridge. The spout outlet incorporates a plastic aerator. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies), incorporating a quarter turn ceramic disc headworks with dome type operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a dome type operating member and a manual override button. The inlets incorporate stainless steel strainer washers, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a manual diverter to shower outlet and a plastic flow straightener. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of two-hole, single outlet, fixed combination tap assembles (chrome plated brass bodies). Incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to a shower outlet. The spout outlets incorporate plastic aerators or flow straightener and supplied with metal backnuts. The products are supplied with a shower hose and handset. Maximum working pressure 10 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Deck mounted, two hole, single outlet fixed combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator and the products are supplied with metal backnuts, shower hose and handset. The shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum Working Pressure 10.0 bar. Maximum operating temperature 60°C
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge incorporating a dome type operating member and a manual override button. Each inlet incorporates a combined NBR washer and stainless steel strainer, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a self cancelling diverter to shower outlet and a plastic flow straightener. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Two-hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic aerator and the product is supplied with plastic back-nuts. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Deck mounted two-hole single outlet, swivel, combination tap assembly (brass body, various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to a shower outlet, also with a single lever operating member. The spout outlet incorporates a plastic aerator and the product is supplied with metal backnuts Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall mounted, three-hole, metal, single outlet (fixed), combination tap assemblies (concealed brass body, various finishes - see model), incorporating quarter turn ceramic disc headwork with single lever, cross top or dome type operating members (see model). The spout outlet incorporates a plastic aerator (F7 & F9 prefix models only). Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Concealed, wall mounted, three-hole, single outlet (fixed) combination tap assembly (brass body - various finishes) incorporating quarter turn ceramic disc headwork. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar
Non-metallic materials and components comply with BS6920 at 60°C
Range of three-hole, single outlet (swivel) combination tap assembly incorporating brass body - various finishes) and quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 60°C
Range of combined bath fillers and overflow waste assemblies (plated brass covers and plastic hoses) with pop-up wastes. Maximum operating temperature 65ºC. Open outlet use only.
Range of QSL stainless-steel expansion bellows with either threaded or flanged end connections. Maximum working pressure: See models. Maximum operating temperature 99°C.
`Vortex air` range of free-standing hospital macerators with flow controlled by solenoid valve and discharged via type AB air gap assembly (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 9.0 bar. Cold water use only.
Range of expansion vessels with stainless steel bodies incorporating a butyl rubber membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Models ALT-ST0019 & ALT-ST0019 are supplied with a pressure gauge. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of in-line water filters with polypropylene bodies. Maximum working pressure 8.5 bar. Cold water use only.
Non-metallic materials and components comply with BS6920 at cold water use only°C
Stainless steel press fittings for use with 316L & 304 stainless steel tube incorporating EPDM ‘O’ rings. The fittings and tube are assembled using a crimping tool. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
alpex Duo XS and alpex L (PPSU & Brass) ranges of press fittings for use with alpex Duo XS (F and TH press profiles) & alpex L pipe (F press profile only). Maximum working pressure 10.0 bar. The maximum operating temperature is 95oC.
PLAS-FIT range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of Conex >B< press fittings incorporating copper & brass bodies for use with copper tube (manufactured to EN1057). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of copper end feed solder fittings for use with copper tube (EN1057). For above and below ground use. Maximum working pressure for sizes 8mm to 54mm is 25.0 bar. Maximum working pressure for sizes above 54mm is 16.0 bar. Maximum operating temperature 99°C.
Dual flush WC drop valve with an internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
Dual flush WC outlet valve with ABS body. The valve incorporates an internal overflow and is operated via a push button assembly for either full or reduced flush. Maximum operating temperature – Cold water use only.
Range of urinal flushing mechanisms incorporating nylon bodies and a solenoid valve which controls the flow and is actuated via an infra-red sensor. The inlet of the solenoid valve incorporates a stainless-steel strainer. Maximum working pressure 5.0 bar. Cold water use only.
Range of wall mounted combination boilers providing domestic hot water via a heat exchanger and pressurised central heating system. The products can be supplied with a rigid or flexible filling loop or keyless filling link. The flexible and rigid filling loops incorporate a flexible hose or copper pipe, isolation valve, double check valve assembly (suitable for back flow protection against fluid category 3). The keyless filling link incorporates a CAB backflow prevention device (suitable for back flow protection against fluid category 3). The products also incorporate an expansion vessel and pressure relief valve set at 3.0 bar. Maximum working pressure of primary circuit 2.5 bar. Maximum operating temperature of primary circuit 85°C Maximum working pressure of secondary circuit 8.0 bar Maximum operating temperature of secondary circuit 60°C
Preheat accessory assembly for connection to the domestic hot water circuit of a combination boiler. Incorporates flow sensor, flow restrictor, flow silencers, pre-heat sensor and filter. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of water meters with brass bodies, plastic transducers, and EPDM O-rings. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of water meters with plastic bodies. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of water meter chambers with plastic or DZR brass body manifold assemblies. The inlet incorporates a screw down isolation valve or quarter turn isolation valve (DZR brass model) & the chamber incorporates non-return valves (not suitable for back flow protection). Maximum working pressure 12.0 bar. Cold water use only.
Range of vertical multistage pumps with cast iron bodies with a black electrodeposition coating, stainless-steel impellers, shaft and outer sleeve. Maximum working pressure: MVX 30 & MVX 45- 32.0 bar, MVX 65 & MVX95 VR - 25.0 bar. Cold water use only.
Range of booster pumps with stainless steel bodies, plastic impellers, and NBR ‘O’-rings. The products incorporate a temperature sensor, pressure sensor, pressure vessel and a non-return valve integral to the pump chamber. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C.
Range of wall mounted overhead shower outlets, (chrome or gold plated brass bodies).
Non-metallic materials and components comply with BS6920 at 85°C
Range of shower handsets, (plastic bodies – various finishes) incorporating a plastic flow regulator in the inlets.
Non-metallic materials and components comply with BS6920 at 65°C
Range of multi-function overhead shower outlets, (plastic bodies – various finishes). The inlets incorporate plastic flow restrictors and stainless-steel strainer washers.
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall and ceiling mounted shower arms with (brass bodies - various styles and finishes). Maximum operating temperature 60°C. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower outlets with various finishes, consisting of a shower hose, handset, riser rail and a brass wall mounted inlet. Maximum operating temperature 60°C.
Page 102 of 204
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.