Range of two hole, single outlet fixed combination tap assemblies (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic aerators. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Wall mounted bar type thermostatic bath shower mixer (chromium plated brass), incorporating a diverter valve controlling the flow to either the spout outlet or shower outlet with a single lever operating member with manual override. The temperature is controlled independently via a thermostatic cartridge using a single lever or dome type operating members with a manual override. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating ceramic disk headworks with single lever operating members and manually operated diverters to shower outlets. The spout outlets incorporate plastic aerators (T7111, T739001 & T740001) or plastic flow straightners (T7501M & T749001),except model T8701 that has an open spout outlet. The products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C (on model T740001).
Range of two-hole, single outlet (fixed) combination tap assemblies, (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to the shower outlet. The products are supplied with a shower hose, handset and metal backnuts. Maximum working pressure 10.0 bar. temperature 75°C.
A range of two-hole, single outlet, fixed, combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to a shower outlet. The spout outlet incorporates plastic aerators or flow straightener and is supplied with metal backnuts. The products are supplied with a shower hose, handsets and metal backnuts. Maximum working pressure 10 bar.
Range of deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a half-turn ceramic disc headwork, both controlling the flow and manually diverting the flow to a shower outlet connection. Temperature is controlled independently via a thermostatic cartridge. The spout outlet incorporates a plastic aerator. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Range of deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a half-turn ceramic disc headwork, both controlling the flow and manually diverting the flow to a shower outlet connection. Temperature is controlled independently via a thermostatic cartridge. The spout outlet incorporates a plastic aerator. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and a manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. Products are supplied with a shower hose and handset and plastic backnuts. Maximum working pressure 6.0 Bar. Maximum operating temperature 60°C.
Range of deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a half-turn ceramic disc headwork, both controlling the flow and manually diverting the flow to a shower outlet connection. Temperature is controlled independently via a thermostatic cartridge. The spout outlet incorporates a plastic aerator. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Range of deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a half-turn ceramic disc headwork, both controlling the flow and manually diverting the flow to a shower outlet connection. Temperature is controlled independently via a thermostatic cartridge. The spout outlet incorporates a plastic aerator. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies), incorporating a quarter turn ceramic disc headworks with dome type operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a dome type operating member and a manual override button. The inlets incorporate stainless steel strainer washers, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a manual diverter to shower outlet and a plastic flow straightener. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 65°C
Deck mounted, two hole, single outlet fixed combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator and the products are supplied with metal backnuts, shower hose and handset. The shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum Working Pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Two hole, wall mounted, single outlet fixed combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headworks with a single lever operating member and self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. Maximum Working Pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating ceramic disk headworks with single lever operating members and self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener and product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet, fixed combination tap assembles (chrome plated brass bodies). Incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to a shower outlet. The spout outlets incorporate plastic aerators or flow straightener and supplied with metal backnuts. The products are supplied with a shower hose and handset. Maximum working pressure 10 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Deck mounted, two hole, single outlet fixed combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator and the products are supplied with metal backnuts, shower hose and handset. The shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum Working Pressure 10.0 bar. Maximum operating temperature 60°C
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted, concealed, three hole single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn, ceramic disc headworks with cross top (14415W-3-CP) or single lever (14415W-4-CP) operating members. The spout outlet incorporates a plastic aerator. Maximum operating temperature 60°C. Maximum operating pressure 4.1 bar.
Range of deck mounted three hole single outlet (fixed) combination tap assemblies with brass bodies (chromium plated), incorporatinig ceramic disc headworks with cross top (14428W-3-CP) or single lever (14428W-4-CP) operating members. The product is supplied with stainless-steel braided EPDM lined flexible hose assemblies to connect the headworks to the spout outlet. Spouts incororate plastic flow straightners. Maximum working pressure 5 bar. Maximum operating temperature 60°C
Sensor control boxes, flow is controlled using a solenoid valve assembly. Flow is activated via infra-red sensor and product incorporates a stainless steel filter and EPDM ‘O’-rings. Maximum working pressure 7.0 bar. Maximum operating temperature 75°C.
Range of combined bath fillers and overflow waste assemblies (plated brass covers and plastic hoses) with pop-up wastes. Maximum operating temperature 65ºC. Open outlet use only.
Range of wall mounted spouts with a brass body (various finishes, see model). The outlet incorporates a plastic aerator. Maximum operating temperature - 60°C
Range of QSL stainless-steel expansion bellows with either threaded or flanged end connections. Maximum working pressure: See models. Maximum operating temperature 99°C.
Range of expansion vessels with stainless steel bodies incorporating a butyl rubber membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Models ALT-ST0019 & ALT-ST0019 are supplied with a pressure gauge. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of in-line water filters with polypropylene bodies. Maximum working pressure 8.5 bar. Cold water use only.
Non-metallic materials and components comply with BS6920 at cold water use only°C
Stainless steel press fittings for use with 316L & 304 stainless steel tube incorporating EPDM ‘O’ rings. The fittings and tube are assembled using a crimping tool. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of copper and brass press-fit fittings with HNBR o-rings, for use with copper tube manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
alpex Duo XS and alpex L (PPSU & Brass) ranges of press fittings for use with alpex Duo XS (F and TH press profiles) & alpex L pipe (F press profile only). Maximum working pressure 10.0 bar. The maximum operating temperature is 95oC.
PLAS-FIT range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of dual flush WC outlet valves. The valve incorporates an internal overflow and is operated via a push button assembly for either full or reduced flush. Cold Water Use
Preheat accessory assembly for connection to the domestic hot water circuit of a combination boiler. Incorporates flow sensor, flow restrictor, flow silencers, pre-heat sensor and filter. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of water meters with black epoxy coated bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Conealed wall mounted installation set with a brass body. Maximum working pressure 10 bar. Maximum operating temperature 70°C
Range of vertical multistage pumps with cast iron bodies with a black electrodeposition coating, stainless-steel impellers, shaft and outer sleeve. Maximum working pressure: MVX 30 & MVX 45- 32.0 bar, MVX 65 & MVX95 VR - 25.0 bar. Cold water use only.
Range of booster pumps with stainless steel bodies, plastic impellers, and NBR ‘O’-rings. The products incorporate a temperature sensor, pressure sensor, pressure vessel and a non-return valve integral to the pump chamber. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C.
Shower kit comprising of chrome plated wall mounted shower outlet, shower hose and handset. The inlet incorporates a stainless-steel strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower outlets and shower handsets with plastic bodies (various finishes) and multi-spray patterns depending on model. Maximum operating temperature 50°C.
Range of shower handsets, (plastic bodies - various finishes) incorporating a plastic flow regulator on the inlet.
Non-metallic materials and components comply with BS6920 at 65°C
Range of single and multi-function overhead shower outlets, (plastic bodies - various finishes). The inlets incorporate a combined washer with a stainless-steel strainer. The inlets also incorporate a plastic flow restrictor (except for the A957516##, A957517##, A957518## and A957519## models).
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall and ceiling mounted shower arms with (brass bodies - various styles and finishes). Maximum operating temperature 60°C. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower outlets with various finishes, consisting of a shower hose, handset, riser rail and a brass wall mounted inlet. Maximum operating temperature 60°C.
Range of shower rail kits, (chrome plated - plastic bodies) incorporating a shower handset, shower hose and adjustable shower rail. Maximum operating temperature 80°C. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 80°C
Range of overhead shower outlets, (brass bodies - Various finishes. The inlet incorporates a stainless steel filter washer and an approved check valve, however, the complete product has not been fully tested to demonstrate it provides backflow protection.
Non-metallic materials and components comply with BS6920 at 65°C
Range of shower rail kits, (chrome plated - plastic bodies) incorporating a shower handset, shower hose and adjustable shower rail. Maximum operating temperature 80°C. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 80°C
Range of drain taps with a brass body and rising spindle headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Two hole deck mounted, single outlet (swivel) laboratory tap incorporating a brass body (with white plastic coating) and non-rising spindle headworks with dome type operating members. The spout outlet incorporates a plastic aerator and the product is supplied with metal backnuts. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C
Range of pillar taps ( brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with various type operating members. The spout outlets incorporate plastic flow straighteners (except models 173601 & 173602 that have open outlets) and the products are supplied with metal back nuts. Maximum working pressure 10 bar. Maximum operating temperature 85°C.
Range of pillar taps ( brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with various type operating members. The spout are open outlets and the products are supplied with metal back nuts. Maximum working pressure 10 bar. Maximum operating temperature 85°C.
Page 93 of 236
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.