Range of combined bath filler and overflow waste assemblies incorporating a cable operated pop-up waste. The outlet incorporates a plastic flow straightener. Maximum operating temperature 60°C.
Range of wall mounted or floor standing spout outlets (fixed or swivel - see model, chromium plated brass). All models incorporate a plastic flow straightener, except for the 93-6106-01 model which has a plastic aerator.
Non-metallic materials and components comply with BS6920 at 60°C
Range of deck mounted spout outlets (fixed or swivel - see model, chromium plated brass) incorporating a plastic flow straightener. The products are supplied with metal backnuts.
Non-metallic materials and components comply with BS6920 at 60°C
Range of swivel spout outlets with brass or stainless-steel bodies supplied in various finishes (see model). The products also incorporate a plastic aerator. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of longitudinal (EFW) welded stainless steel (Grade 304/304L & 316/316L) pipes. Maximum working pressures: 1¼” sch 10: below ground = 55.0 bar. Above ground = 74.0 bar. 1½” sch 10: below ground = 48.0 bar. Above ground = 64.0 bar. 2” sch 10: below ground = 38.5 bar. Above ground = 51.0 bar. 2½” sch 10: below ground = 34.5 bar. Above ground = 46.0 bar. 3” sch 10: below ground = 28.0 bar. Above ground = 38.0 bar. 4” sch 10: below ground = 22.0 bar. Above ground = 29.0 bar. 5” sch 10: below ground = 19.5 bar. Above ground = 26.0 bar. 6” sch 10: below ground = 16.0 bar. Above ground = 22.0 bar. 8” sch 10: below ground = 14.0 bar. Above ground = 18.0 bar. ½” sch 40 & ¾” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 1” sch 40: below ground = 30.0 bar. Above ground = 40.0 bar. 1¼” sch 40 & 1½” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 2” sch 40: below ground = 54.5 bar. Above ground = 72.0 bar. 2½” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 3” sch 40: below ground = 52.0 bar. Above ground = 69.0 bar. 4” sch 40: below ground = 44 bar. Above ground = 58.0 bar 5” sch 40: below ground = 38.5 bar. Above ground = 51.0 bar. 6” sch 40: below ground = 35.0 bar. Above ground = 46.0 bar. 8” sch 40: below ground = 31.0 bar. Above ground = 41.0 bar. Maximum operating temperature 100°C.
‘Super Speedfit’ range of plastic pushfit fittings (black, light grey, dark grey, white, natural, and red) for use with John Guest LLDPE tubing (blue, black, natural, green, orange, red, white and yellow). Operating parameters: 5/32”, ¼”, 5/16”, 4mm & 6mm = 16.0 bar cold water & 8.0 bar at 65°C. 3/8” = 10.0 bar cold water & 7.0 bar at 65°C. ½” = 10.0 bar cold water & 6.0 bar at 65°C. 8mm, 12mm & 15mm = 10.0bar cold water & 6.0 ba at 65°C. 10mm = 10.0bar cold water & 7.0 bar at 65°C.
“Super Speedfit” range of push-fit fittings with polypropylene bodies and EPDM or NBR ‘O’-rings (NC2301 model only) for use with John Guest LLDPE tubing (blue, black, natural, green, orange, red, white and yellow). Maximum working pressure and maximum operating temperature: 10bar @20°C, 4 bar @60°C.
‘Flowflex’ and ‘Lamontite’ ranges of brass, chromium plated brass, nickel plated brass and DZR brass compression fittings for use with copper pipe (manufactured to to BS EN1057:2006 + A1:2010). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Primaflow ranges of brass, DZR brass, chromium plated brass, nickel plated brass and DZR brass compression fittings for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
CB Ranges of brass, DZR brass, chromium plated brass, nickel plated brass and DZR brass compression fittings for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
CB ranges of brass, chromium plated brass, nickel plated brass and DZR brass compression fittings for use with copper pipe (manufactured to to BS EN1057:2006 + A1:2010). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Ranges of brass & chromium plated brass, nickel plated brass compression fittings for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of press-fit fittings with stainless steel bodies incorporating EPDM ‘O’-rings for use with SS316L pipes. Maximum working pressure 16 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of commercial air or liquid cooled ice making machines with water controlled via solenoid valve. Maximum working pressure 5.5 Bar COLD WATER USE
Range of ultrasonic water meters with plastic (PL) or brass (BR) bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating Temperature 50 C
‘Homebooster’ pump with stainless steel body, plastic impeller and EPDM rubber ‘O’-rings. The product is supplied with two loose brass ¾” captive nut x ½” BSP (M) connectors and fibre gaskets for installation on the inlet and outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of wall mounted and ceiling mounted shower heads available in different finishes and flow rates. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 65°C
Range of shower handsets and shower heads with plastic bodies (chrome plated, except for the DS1200W and DS3200W models which are white) and NBR gaskets.
Non-metallic materials and components comply with BS6920 at 65°C
Range of ceiling or wall mounted shower outlets, (chrome plated brass bodies) incorporating EPDM `O` rings. Model 10 921 180 is a concealed mounting unit.
Non-metallic materials and components comply with BS6920 at 60°C
Page 85 of 214
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.