Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Greenstar Heatslave II range of floor standing oil-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, which incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The cold water inlet incorporates a screwdriver operated spherical valve followed by a plastic flow regulator inserted within the pipework. Maximum working pressure: Primary circuit 2.5 bar. Secondary circuit 10.0 bar. Maximum operating temperature 82°C.
"Greenstar" range of indirect heat interface units and "Flow 8000" (added December 2024) range of direct heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel. The products are sold with or without a prefix kit (see model), which comprises of a mounting bracket that includes spherical valves for all circuits. The "Greenstar" indirect models include a pressure relief valve (set at 3.0 bar) on the space (central) heating circuit. Greenstar models: Maximum working pressure district heating 10.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary). Flow 8000 models (added December 2024): Maximum working pressure district and space heating 10.0 bar. Maximum working pressure secondary hot water 10.0 bar. Maximum operating temperature 60°C (secondary) and 90°C (primary).
Range of in-line water meters with brass bodies and plastic inlet filters. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C (SJ & ELECTO-SJ models) Maximum operating temperature 30°C (AP VARIO and AP RADIO models)
Range of water meter manifolds (plastic body). Model WB31520CG incorporates a single check valve cartridge and model WB31520CGDCV two single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 16.0 bar. Cold water use only.
Range of pump inverters with plastic bodies, NBR rubber and EPDM rubber seals and ‘O’-rings. The products incorporate an inline resilient trim non-return valve. Maximum working pressure 13.0 bar. Cold water use only.
Bypass valve assembly with a plastic body and push/pull operating method to switch flows between different outlets. The product incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Cold water use only.
Union ball, non-return valve with a plastic PVC body. Maximum working pressure 10.0 bar. Cold water use only.
‘EVE Whole house’ twin impeller booster pump with a plastic body and impellers and EPDM ‘O’-rings. The inlet and outlet hoses incorporate a screwdriver operated isolation valve. The pump body outlets incorporate a non-return valve. The product is supplied with two loose combined EPDM and stainless steel inlet washers and two loose EPDM outlet washers. Maximum working pressure 3.0 bar. Maximum operating temperature 65°C.
‘ECOCIRC XL N’ & ‘ECOCIRC XL PLUS N’ range of circulation pumps with stainless steel bodies, plastic impellers, and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Wall mounted shower head and arm (chromium plated brass) incorporating a NBR seal and TPE gasket. The inlet to the shower head from the shower arm incorporates a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working temperature 60°C.
Range of shower handsets and shower kits. Shower kits 2.1703.391, 2.1703.015 & 2.1703.016 incorporate a shower handset, shower hose and riser rail. Shower handset inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Range of shower outlets incorporating brass bodies (various finishes) and NBR ‘O’-rings. Maximum operating temperature 85°C.
Range of shower outlets and shower kits. Shower outlets consisting of wall and ceiling mounted shower heads and hand shower. The inlets incorporate stainless steel flow regulators and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The shower kits can consist of shower hose, shower handset, riser rail and wall outlet elbow with bracket (depending on model). Shower handset inlet incorporates a stainless-steel strainer. Both the outlet of the wall elbow and inlet of shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of shower outlets incorporating brass bodies (various finishes) and NBR ‘O’-rings. Maximum operating temperature 85°C.
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Page 72 of 590
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.