Range of electric instantaneous water heaters. The DEX and DCX models incorporate a spherical ball valve on the inlet. The CEX and DEX models incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet incorporates a strainer. Maximum working pressure 10 bar (DEX models only) All other models open outlet. Maximum operating temperature: ES3/4/5 and Zip Hydrotap G4/G5 ranges – 65ºC. CEX, DEX and DCX ranges - 70°C.
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Range of pressure limiter with stainless steel spring, plastic or chrome plated brass bodies. A5.0022.0 and A5.0027.0 incorporate with a stainless-steel mesh filter. Maximum working pressure 10.0 Bar. Maximum operating temperature 65˚C.
Permanent filling/ pressurisation device for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. In the event of a fall in system pressure, and only if the mains pressure is adequate, a solenoid valve operates to allow water into the system. At all other times a second solenoid valve drains the fill chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Maximum working pressure 6.0 Bar. Cold water use only.
Range of vertical multistage booster pumps, with stainless steel bodies and impellors. Maximum working pressure: See models Maximum working temperature 85°C.
Range of multi-function shower handsets with white or chrome plated plastic bodies. The inlet incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower outlets and shower arms (brass bodies - various finishes - see model). The wall mounted and ceiling mounted shower heads incorporate integral plastic flow regulators and also include stainless steel strainers on the inlets. The shower handset has a plastic flow regulator and a stainless steel strainer on the inlet. Maximum operating temperature 60°C.
Range of shower handsets with a black plastic body and EPDM ‘O’-rings. Model includes a trigger mechanism that alters the spray pattern. Maximum operating temperature 60°C.
Range of shower handsets with chrome plated ABS bodies incorporating NBR o rings. Maximum operating temperature 60°C.
Range of shower handsets (chrome plated brass), shower hoses, handset brackets and cover plates. The shower handset inlets incorporate stainless-steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60.0°C
Range of shower handsets with brass bodies, available with various finishes. The inlet incorporates a plastic regulator and incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 80°C
Range of shower handsets with plastic bodies (chrome plated or white finish). Maximum operating temperature 60.0°C
Range of hose union, spherical valve type bib taps with (nickel plated) brass bodies and chrome plated brass ball. The outlet incporates a plastic flow straightener Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Pillar tap incorporating (chromium plated) brass body quarter turn ceramic disc headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C. The product is supplied with metal backnuts.
Range of PEX lined, interlocked, metal shower hoses. Maximum operating temperature 60°C.
Range of wholesome-water nickel plated brass manifolds for use with ‘Emmeti Gerpex RA’ Pexb/Al/Pexb Multilayer pipe and ‘Emmeti Alpert’ PERT/AL/PERT Multilayer Pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. Range of closed circuit use nickel plated brass manifolds for use with ‘JG Speedfit Layflat Polybutylene Barrier Pipe (models 10BPB & 15BPB)’. Maximum working pressure 3.0 bar. Maximum operating temperature 92°C.
Two-hole wall mounted thermostatic mixing valve (chrome plated brass body). Incorporating ceramic disc headwork, with a lever type operating member. The temperature is controlled independently via a thermostatic cartridge with a lever type operating member and manual override button. Both inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10 bar. Maximum operating temperature 60°C
Range of wall mounted, thermostatic blending valves (chrome plated brass bodies) incorporating quarter turn ceramic disc headwork with a single lever operating member. Temperature is independently controlled via a thermostatic cartridge with cross top operating members. Both inlets incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, thermostatic blending valves (chrome plated brass bodies) incorporating quarter turn ceramic disc headwork with a single lever operating member. Temperature is independently controlled via a thermostatic cartridge with cross top operating members. Both inlets incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Page 67 of 326
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.