Range of Single hole, single outlet fixed combination tap assemblies incorporating ceramic disc cartridge headworks with single lever operating members. Models XB-MP-028, XB-MP-030, XB-MP-050, XB-MP-051, and XB-MP-052 incorporate plastic aerators, Models XB-MP-027, XB-MP-029, XB-MP-031 and XB-MP-032 incorporate a plastic flow straightener. Maximum working pressure all models 10.0 bar. Maximum operating temperature 85⁰C for Models XB-MP-018 and XB-MP-035 all other models are 65⁰C.
Range of single hole, single outlet fixed combination tap assemblies with stainless steel bodies (various finishes) incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65⁰C.
Single hole, single outlet, fixed combination tap assemblies (brass bodies - various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener and an optional flow regulator. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of single-hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The products are supplied with click type pop up waste (verified by test). Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C
Range of single-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. The ‘2920’ models are supplied with a lever operated pop-up waste. The inlets incorporate plastic strainers. SECURITHERM EP BIOSAFE models also incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of single hole, single outlet (fixed) combination tap assemblies with (brass bodies - various finishes), incorporating ceramic cartridge headworks and dome type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure; 5 Bar Maximum operating temperature 65°C
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates plastic flow straighteners. The products are supplied with a 15x15mm compression single check valve assembly (suitable for backflow protection against Fluid Category 2) which also incorporates an isolation valve, intended for installation at each inlet. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
Wall mounted two-hole, single outlet (fixed) combination tap assemblies with brass bodies (chromium plated), incorporating a ceramic cartridge headworks and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure: 5 bar. Maximum operating temperature: 60°C
Range of two hole, deck mounted, single outlet fixed combination tap assemblies incorporating quarter turn ceramic disc headworks with single lever operating members. Models XB-SL-046 and 079 incorporate plastic aerators, models XB-SL-049, 051 and 053 incorporate plastic flow straighteners. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature for XB-SL-038 85oC, all other models are 65⁰C.
Three hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic disc headwork with single lever operating members and a manually operated bath to shower diverter. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of three-hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes). Incorporating a ceramic cartridge headwork with a single lever operating member and self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The product is supplied with metal backnuts Maximum working pressure 10.0 Bar. Maximum operating temperature 60 °C
Range of single hole, double outlet (swivel) combination tap assemblies (various finishes) with electronically controlled functions to allow the tap to dispense boiling water, chilled water or sparkling water from under counter units (not supplied or part of this approval) and a ceramic cartridge headwork with single lever operating member controlling the flow of normal mixed water. The spout outlet incorporates a plastic aerator. Maximum working pressure: 5.0 Bar. Maximum operating temperature: 98.0°C.
Range of wall mounted bath spout outlets with brass bodies (various finishes) with a plastic aerator incorporated into the outlet. Maximum working pressure: 5 bar. Maximum operating temperature 60°C
Mini shock arrestor with a stainless steel body. Maximum working pressure 15.0 bar . Maximum operating temperature 70°C.
Range of expansion vessels with white epoxy coated steel bodies and butyl diaphragm. Please refer to model for maximum working pressures. Maximum operating temperature 70°C. Maximum working pressure 10.0 bar (all except two models), 8.0 bar (24749 & 24809 only).
Range of shock arrestors comprising of a copper tube and brass adapter. Max working pressure 10.0 Bar. Max working temperature 80°C.
Range of copper press fittings (‘M’ type crimp profile) and brass threaded adaptor fittings, for use with copper pipe (EN1057). Maximum operating pressure - 16 bar @ 30°C and 10 bar @ 95°C.
Range of press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of “JRG Sanipex MT” compression fittings with EPDM ‘O’-rings for use with “JRG Sanipex MT ECO” multilayer pipes (PE-RT II/Al/PE-RT II). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of plastic pushfit fittings for use with ‘Bevex’ polypropylene pipe. Maximum working pressure 6.5bar. Cold water use only.
‘ZL’ range of U profile press fittings (nickel plated brass bodies) for use with ‘ZL’ range of PERT/AL/PERT multi-layered pipes. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
NovaTherm range of U profile press fittings (nickel plated brass bodies) for use with NovaTherm range of PERT/AL/PERT multi-layered pipes. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
B Profile range of 316L & 304 stainless steel press fittings with EPDM ‘O’-rings for use with stainless steel pipe manufactured to EN 10312, for both above and underground use. Joints are achieved by the use of a press fitting tool. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
Range of R-154 stainless steel pressed collars incorporating stainless steel bodies (304L or 316L) and are only to be used with stainless steel pipe. Maximum working pressure for sizes up to DN150 (FCM models) or DN125 (FCI models) is 25.0 bar. Maximum working pressure for size DN200 (FCM models) or DN150 and DN200 (FCI models) is 16.0 bar. Maximum operating temperature 99°C.
Silicon Bronze bodies Press Fittings with EPDM `O`-rings. For use with copper pipe manufactured in accordance with BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Copper press-fit fittings with copper with EPDM `O`-rings. For use with copper pipe manufactured in accordance with BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
FLOMASTA range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Indirect heat interface unit with copper brazed, stainless-steel heat exchangers, providing heating and instantaneous hot water. The product incorporates an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the heating circuit set @ 2.5 bar. The DHW and heating circuits are both fitted with drain valves incorporating cover caps. Maximum working pressure 16 Bar (Primary), 10 Bar (DHW) & 3 Bar (Heating) Maximum operating temperature 95°C
‘PREMIX’ range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both the domestic hot water and primary circuit are controlled via spherical valves. Maximum working pressures: Primary circuit: 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature both circuits: 80°C.
Range of in-line water meters with brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of in-line water meters with plastic bodies. The inlet incorporates a plastic filter. Maximum working pressure; 16 Bar Maximum operating temperature 50°C
Range of IUW ultrasonic water meters with blue epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature: 50°C.
Range of in-line water meters with brass bodies and plastic turbines. The inlets incorporate plastic filters, and the outlets incorporate non-return valves (not suitable for backflow protection). Maximum working pressure 16.0 Bar. Maximum operating temperature 65.0°C.
`Prox’ and ‘Wave` ranges of sensor operated flow control devices incorporating a normally closed solenoid valve to control the flow and operated via an infra-red sensor. The inlet incorporates a stainless-steel strainer. Maximum working pressure 8 Bar Maximum operating temperature 65°C
Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of single stage booster pumps incorporating a flow switch. Model 46349 CH 12-14 B is supplied with a pressure vessel and incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with a strainer and stainless-steel braided EPDM lined flexible connection hoses. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of two, three and four pump cold water booster sets. The products incorporate a suction and discharge manifold and pumps. Maximum working pressure 10 bar. Cold water use only.
Range of shower outlets comprising of shower heads all incorporating stainless-steel strainer washers (plastic bodies-various finishes) and handheld showers (plastic bodies - various finishes). Maximum operating temperature 75°C.
Range of overhead shower and shower handsets with (brass or plastic bodies – various finishes), incorporating a stainless-steel strainer on the inlets. Open outlet use only Maximum operating temperature – 85°C.
Range of shower handsets with (plastic bodies - various finishes) incorporating a plastic flow restrictor in the inlet. Open Outlet use only Maximum operating temperature 60.0°C
Range of shower outlets comprising of shower heads all incorporating stainless-steel strainer washers (plastic bodies-various finishes) and handheld showers (plastic bodies - various finishes). Maximum operating temperature 75°C.
Range of shower outlets with ABS plastic bodies and NBR and EPDM O-rings. The inlets incorporate stainless steel strainers. Maximum working pressure: Open Outlet use only. Maximum operating temperature 75°C
Range of shower handsets with plastic bodies (various finishes), handset holder, riser rail and TPE inner lined multilayered shower hose. The handset incorporates a flow restrictor at the inlet. Open Outlet. Maximum operating temperature: 60.0°C.
Range of ABS plastic shower handsets, (various finishes) Maximum operating temperature 85°C.
Range wall mounted shower outlet connectors with brass bodies, chrome finish. The outlet incorporates a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum operating pressure 10 Bar. Maximum operating temperature 70°C.
Range of drain valves with a brass bodies, spindle and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of pillar taps (chromium plated brass) incorporating non-rising spindle headwork with cross top operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 7.0 bar. Maximum operating temperature 65°C.
Range of stainless-steel interlocked shower hoses and shower hose extension pieces (smaller length versions) incorporating PE/EPDM and PEX inner tube materials. Available with various surface finishes and end connectors. For further details see model section. Maximum working pressure open outlet use. Maximum operating temperature 85.0°C
Range of stainless steel inter-locked shower hoses incorporating PVC linings in various finishes. Maximum operating temperature 65°C.
Range of elastomeric shower hoses with EPDM lining and ‘O’-rings. The product incorporates a flow restrictor. Maximum operating temperature 60.0°C Open outlet use only
Page 66 of 82
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.