Two-hole, single outlet (fixed) combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset and metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Range of two hole, single outlet (swivel) combination tap assembly with brass bodies (chrome plated), incorporating quarter turn ceramic disc headworks and single lever operating members (model 740910) or non-rising spindle headworks with dome type operating member (model 546840). The spout outlet incorporates a plastic aerator or plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of two hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated), incorporating quarter turn ceramic disc headwork with single lever operating members and lockable diverter to shower outlet. The spout outlet incorporates a plastic aerator. The product includes a shower hose, shower handset and is supplied with metal backnuts. Model PAX106 is also supplied with a flow regulator. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of three hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating. The spout outlet incorporates an aerator or a flow straightener. Product supplied with stainless steel braided EPDM lined flexible connection hoses. Maximum working pressure 3.5 Bar. Maximum operating temperature 60°C.
Four-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and self-cancelling diverter to shower outlet. The spout incorporates a flow restrictor on the inlet and a plastic aerator at the outlet. The product is supplied with a shower hose, handset and metal backnuts. The inlets of the handset and diverter incorporate an approved single check valve cartridge, verified by test, suitable for backflow to fluid category 2. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Five-hole, single outlet, fixed combination tap assembly (chromium plated brass) with quarter turn ceramic disc headworks with dome type operating members. The spout inlet has a plastic flow regulator the spout outlet incorporates a plastic aerator. The self-cancelling diverter, shower outlet and the shower handset incorporate an approved check valve cartridge, verified by test, suitable for backflow to fluid category 2. The product is supplied with metal back nuts, shower hose and shower handset. Maximum working pressure 10 bar. Maximum working temperature 60°C
Range of deck mounted spout outlets incorporating chrome plated brass body (model F2158.WR) or a stainless-steel body (model F2943INOX.WR). The outlets incorporate a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted spout outlets incorporating chrome plated brass bodies (models CPHSP2929, ZCPHSP2929, CPHMA2418 & ZCPHMA2418) or a stainless-steel body (models CPHSP2944SS & ZCPHSP2944SS). The outlets incorporate a plastic flow straightener (models CPHSP2929 & ZCPHSP2929) or a plastic aerator (models CPHMA2418, ZCPHMA2418, CPHSP2944SS & ZCPHSP2944SS) Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted spout outlets incorporating chrome plated brass body (models CPHSP2158 & ZCPHSP2158) or a stainless-steel body (models CPHSP2943SS & ZCPHSP2943SS). The outlets incorporate a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted spout outlet (chromium plated brass) incorporating a plastic aerator. Maximum operating temperature 60°C, open outlet use only.
Range of horizontal or vertical expansion vessels with an EPDM membrane. Maximum working pressure 10.0 or 16.0 bar (please refer to model). Maximum operating temperature 100°C.
Range of tap outlets with plastic bodies incorporating a filter within the body, incorporating a hollow fibre filter membrane. The inlet of the filter incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The filters are supplied with (and must be used with) a chrome plated brass adapter which incorporates a pastic flow regulator. Maximum operating temperature 60°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Instantor range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Wavin range of Tigris K1 (plastic bodies) and M1 (brass bodies) press-fit fittings for use with Tigris PEX/AL/PE HD (50mm & 63mm) and Tigris PERT/AL/PERT WT (75mm) barrier pipes. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.
Range of solder ring copper fittings for use with copper tube to EN 1057. The HLSRDPMFWT and HLSRDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring brass fittings for use with copper tube (manufactured to EN 1057). The HLSR20CB-d tank connector incorporates an EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring copper fittings for use with copper tube to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass compression fittings incorporating brass ring olive to be used with pipe manufactured to EN ISO 15875. Maximum working pressure 8.0 bar. Maximum operating temperature 90°C.
The 3G Metric Imperial range of plastic compression fittings with polypropylene bodies, compression nut and silicone seal for use with PE80 pipe (manufactured to BS EN 12201). Maximum working pressure: Fittings when used with PE100 pipe = 16.0 bar. Fittings when used with PE80 pipe = 12.0 bar. For above and below ground and cold water use only.
Range of ductile iron pipe couplings for use with stainless steel and carbon steel pipe. The carbon steel pipe must incorporate a suitable coating or lining for wholesome water use. For maximum working pressure and the type of pipe the fittings are for use with, please refer to model. For above and below ground use. Maximum operating temperature 65°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). The HLE20CB-d tank connector incorporates an EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The HLDPMFWT and HLDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper or gunmetal solder fittings for use with copper pipe. Maximum working pressure 16.0 bar (Sizes 8 - 28mm). Maximum working pressure 10.0 bar (Sizes 35 - 108mm). Maximum operating temperature 100°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
WC dual flush outlet valve comprising of ABS plastic body, EPDM gasket and an internal overflow. Cold water use only
Range of heat exchangers connected to copper waste pipe, Where the waste is discharged down a “rotator” into a copper waste pipe, and potable water is returned to the shower/heating device via a copper double walled jacket around the copper waste pipe. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C
Range of 4 or 6 port manifolds with or without water meter manifolds (see model), all with gunmetal bodies. Models with a water meter manifold incorporate a quarter turn stop valve or screw down stop valve (see model), and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Y type fittings incorporating brass body and NBR washer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of brass (chrome plated) quick fit connectors. Maximum operating temperature 60°C
Range of shower heads with brass bodies (various finishes), incorporating EPDM ‘O’-rings and plastic flow regulator. Maximum operating temperature 60°C.
Range of shower handsets (various finishes) incorporating stainless steel strainers. Model 28 588 xxx incorporates flow regulator. Maximum operating temperature 60°C.
Range of showers handsets incorporating plastic bodies (chrome plated) Maximum operating temperature 60°C.
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of drain taps incorporating brass bodies, EPDM seats and washers and a non-rising spindle headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of drain taps incorporating brass bodies, EPDM seats and washers and a non-rising spindle headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pillar taps incorporating brass bodies (chrome plated), and quarter turn ceramic disc headowks. The spout outlet incorporates a flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass). The 595-H1 & K-595-H2 models incorporate a quarter turn ceramic disc headwork with a single lever operating member. The K-595M prefix models incorporate a non-rising spindle headwork with dome type or cross top (see model) operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Pillar tap (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating member and plastic back nuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Pillar taps (chromium plated brass) incorporating a quarter turn ceramic disc headwork with a single lever operating member. The spout outlets incorporate a plastic flow straightener. Model 62454-5001 is supplied with plastic backnuts. Model 62454-5701 is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of stainless steel braided HDPE lined flexible hose assemblies with various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel interlocked shower hoses (various finishes (see model) incorporating an EDPM liner and NBR washers. Maximum working temperature 85°C
Range of automatic air venting valves with DZR brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C.
Wall mounted manual blending shower valve with a brass body (various finishes - see model) incorporating a ceramic cartridge headwork with a single lever operating member. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted (concealed) thermostatic mixing valves with brass bodies, incorporating half turn ceramic disc headworks controlling the flow with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with a dome operating member and manual override button. Both inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of thermostatic blending valves incorporating chrome plated brass bodies. The inlet incorporates a stainless steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models 09 415 is supplied with a rigid connection set and tee piece and model 09 416 is supplied with a PEX lined flexible hose and tee piece connection set. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of T-type thermostatic blending valves (chromium plated DZR brass body). The inlets incorporate stainless steel strainers and an approved check valve cartridge which has been verified by test as suitable for backflow protection against Fluid Category 2. Compression models are for use with copper pipe manufactured to EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted thermostatic shower valves incorporating brass bodies (various finishes), self-cancelling diverter and self-closing headwork. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member. Models 1.1967.001, 1.1967.002, 1.1967.003 & 1.1967.004 are supplied with a shower hose, handset and riser rail and overhead shower. Models 1.1967.005, 1.1967.006, 1.1967.007 & 1.1967.008 are supplied with a shower hose, handset, riser rail & bath filler. Models 1.1967.009, 1.1967.010 & 1.1967.011 are supplied with a shower hose, handset and riser rail, overhead shower & bath filler. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C.
Range of wall mounted thermostatic shower valves (chrome plated brass bodies) incorporating a two-way diverter valve controlling the flow between shower outlets with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member with manual override button. Both inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Page 59 of 204
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.