Range of pump docking manifolds with plastic bodies. Maximum working pressure: 5.5 bar. Cold water only.
‘Hansen True Fit’ range of black coloured, plastic threaded fittings. Maximum working pressure 1/8” – 2” BSP: 16.0bar, 2½” BSP: 12.0bar, 3” – 4”: 10.0bar. Cold water and above ground use only.
Range of in-line flow sensors incorporating either brass (type 230, 235 & 236) or plastic (type 200 & 210) bodies & EPDM ‘O’-rings. Maximum working pressure 12.0 Bar Maximum operating temperature 100.0°C
Range of flow measurement devices (DZR brass) bodies incorporating two test ports. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of stainless steel bodied mechanical pump shaft seals. Cold water use only.
Range of multistage pumps with stainless steel bodies Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of stainless steel or cast iron (with electrolytic coating) bodied, multistage centrifugal pumps with stainless steel impellers. Maximum working pressure: Ranges from 16.0 bar to 30.0 bar (see models). Cold water use only.
Range of overhead shower outlets with (stainless steel bodies - various finishes). The inlet incorporates a combined EPDM washer and an approved check valve cartridge: however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure: Open outlet use only. Maximum operating temperature 65.0°C
Range of shower handsets with (plastic bodies - various finishes), incorporating an approved single check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure: Open outlet use only Maximum operating temperature: 60°C.
Range of shower handsets with chromium plated plastic bodies. Maximum operating temperature 65.0°C Open outlet use only
Shower handsets with chromium plated plastic bodies and a plastic flow regulator in the inlet. Maximum operating temperature 65°C. Open outlet use only.
Range of wall or ceiling mounted shower arms with brass bodies (various finishes). Maximum operating temperature 65°C. Open outlet use only.
Range of shower handsets with brass body available in various finishes. Maximum operating temperature 85°C.
Range of DZR brass and brass bodied in-line Y-Stainers with a stainless-steel mesh. Compression models for use with copper pipe to BS EN1057. Maximum working pressure 10 Bar Maximum operating temperature 60°C.
Range of bib and hose union taps incorporating either brass or DZR brass (142HU prefix models only) bodies and non-rising spindle headworks. The FGK suffix models incorporate a ferrule guard and key (lockshield). The inlet and outlet of the 142HU (508107) and 142HU FGK (501117) models incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperatures: 142HU (508107) and 142HU FGK (508117) models 65°C, all other models 90°C.
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 13.20302.G15.CP5R-8510 | ½” BSP (M) | 16 bar | 85 °C | V&G,WRAS,1/2,MMYY | BODY | No | Rising spindle | Open Outlet | |||
| 13.20302.G20.CP5R-8510 | ¾” BSP (M) | 16 bar | 85 °C | V&G,WRAS,3/4,MMYY | BODY | No | Rising spindle | Open Outlet | |||
| 13.20302.G15.CP5R-8511 | ½” BSP (M) | 16 bar | 85 °C | V&G,WRAS,1/2,MMYY,CR | BODY | No | Rising spindle | Open Outlet | |||
| 13.20302.G20.CP5R-8511 | ¾” BSP (M) | 16 bar | 85 °C | V&G,WRAS,3/4,MMYY,CR | BODY | No | Rising spindle | Open Outlet | |||
| 13.20362.G15.CP5R-8511 | ½” BSP (M) | 16 bar | 85 °C | V&G,WRAS,1/2,MMYY,CR | BODY | No | Rising spindle | Open Outlet |
Wall Mounted Undefinable air gap see IRNs Incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection.
Range of self-closing taps (chromium plated brass) incorporating a push button headwork with a dome type operating member. The inlet hoses each incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 65°C.
Range of self-closing taps (chromium plated brass) with a dome type operating member. The spout outlet incorporates a plastic aerator. Model 02 122 06 99 model is supplied with a metal backnut. Maximum working pressure 10 bar. Maximum operating temperature 65C
‘TAQ PEX’ range of PEX lined flexible hose assemblies with either stainless steel braiding or grey polymeric (PET - Polyethylene terephthalate) braiding. G3/8" captive nut connection includes an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Hoses with compression connections are for use with copper pipe (manufactured to EN1057). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel, interlocked shower hoses with EPDM liner and O-rings. Open outlet use only. Maximum operating temperature 65°C.
Page 547 of 590
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.