Range of single hole, two single outlets (swivel) combination tap assemblies (brass bodies - various finishes). Incorporating ceramic cartridge headwork, single lever operating member controlling both flow and temperature to the spout and spring-loaded pull-down hose. The pull-down hose incorporates a hand spray with a self-closing trigger mechanism. The spout incorporates a ceramic disc headwork controlling the flow with a single lever operating member. The spout outlets incorporate plastic aerators. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
In-line water filter system comprising of a head and replaceable carbon block cartridge (within a fixed housing) for use with John Guest LLDPE pipe. Maximum working pressure 8.6 bar. Cold water use only.
Range of electric instantaneous water heaters. The DEX and DCX models incorporate a spherical ball valve on the inlet. The CEX and DEX models incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet incorporates a strainer. Maximum working pressure 10 bar (DEX models only) All other models open outlet. Maximum operating temperature: ES3/4/5 and Zip Hydrotap G4/G5 ranges – 65ºC. CEX, DEX and DCX ranges - 70°C.
Electric, instantaneous, vented, mains water heaters with plastic housings and silicon gaskets. Model AQ5001353 incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum working pressure 1.5 bar.
Non-metallic materials and components comply with BS6920 at 98°C
Wall mounted shower outlet elbow with a chromium plated brass body incorporating EPDM ‘O’-rings. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower handsets (chrome plated brass), shower hoses, handset brackets and cover plates. The shower handset inlets incorporate stainless-steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60.0°C
Range of shower handsets with brass bodies, available with various finishes. The inlet incorporates a plastic regulator and incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 80°C
Range of angled shower wall outelts with brass bodies (various finishes - see model). The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of chrome plated hand showers with plastic bodies. The inlets incorporate a plastic strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Tempomix 3 794BOX1 concealed, wall mounted shower valve (brass body) for use with Tempomix 3 794218 & Tempomix 3 794219 functional/trim (chromium plated brass) kits. The functional/trim kits incorporate a self-closing spring-loaded headwork with a dome type operating member that controls both flow and temperature. 794219 also incorporates a chrome plated brass shower outlet that has a flow regulator. The inlets to the 794BOX1 incorporate stop valves, plastic filters and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of shower handsets (chrome plated brass bodies). The shower handset incorporates an approved check valve cartridge with a flow regulator, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of deck mounted pull-out shower hose and handsets (various plated brass or stainless-steel bodies). The inlet to the shower handsets incorporates an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature: 60°C
Range of shower elbows/holders with brass or stainless-steel bodies (various finishes). The elbows incorporate a plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models VOLA 070-XX & VOLA 070R-XX are supplied with a shower hose and handset.
Non-metallic materials and components comply with BS6920 at 60°C
Bib taps incorporating either brass or DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Combination tap assembly (chrome plated brass), with a dome type operating member controlling the flow and temperature with a non-concussive thermostatic cartridge headwork. The spout outlet incorporates a plastic aerator. The inlets incorporate approved single check valve cartridges, however, the complete assembly has not been tested to demonstrate backflow protection. Maximum working pressure 5.0 Bar Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Centerstore ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Range of indirect unvented indoor heat pump storage cylinders which consist of a heat pump which sits on top of the tank and heats the hot water via refrigeration pipes which then heats the cylinder by being externally mounted around the cylinder. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressure 6.0 Bar (Secondary) Maximum operating temperature 55.0°C
Range of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The secondary circuit consists of a temperature and pressure relief valve set at 10.0 bar and 90°C and an alternative temperature and pressure relief valve also set at 10.0 bar and 90°C , an inlet control group consisting of a pressure reducing valve pre-set at 3.0 bar, an expansion relief valve set at 8.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum working pressure - Primary circuit: 6.0 bar & Secondary circuit: 7.5 bar Maximum operating temperature 85.0°C
Wall mounted, exposed, manual blending valve (brass body, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic blending valves (brass bodies), with ceramic cartridge headworks controlling the temperature and the flow and a manual diverter that diverts the flow to two outlets. Both have single lever operating members. Maximum working pressure 5.0 Bar Maximum operating temperature 65°C.
Page 54 of 139
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.