Range of shower handsets (chromium plated) brass bodies and NBR O-rings. The inlets incorporate stainless-steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature 60ºC
A range of shower kits and hand showers incorporating metal bodies (chrome plated). Some models are supplied with sliding rails, wall elbows and shower hoses (see models). Maximum working temperature 60°C.
Range of overhead shower outlets with brass bodies in various finishes (See models) incorporating EPDM ‘O’-rings and seals. The inlet to the shower heads incorporate either a plastic steel sieve (26 031 xxx) or a stainless steel (26 032 xxx) has a stainless-steel sieve. The inlet for the shower head incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection (Model 26 031 xxx only). Maximum operating temperature 60°C.
Range of plastic shower handsets (various finishes). Maximum operating temperature 75°C.
Range of flow switches with plastic bodies. The VK308/10/15/20/25/32/40/50M and VKS08/10/15/20/25/32/40/50M prefix models are supplied with an inline brass adaptor. The VK305/306/309M and VKS05/06/09M prefix models are supplied with a brass adaptor for direct insertion into a pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of bib taps incorporating either brass or DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Pillar tap (chromium plated brass) , incorporating a quarter turn ceramic disc headwork with a single lever operating member. The spout outlet incorporates a stainless steel aerator and the product is supplied with a metal backnut. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of self-closing combination taps with brass bodies (chrome plated), incorporating a non-concussive headwork with dome type operating members. The inlets incorporate an approved single check valve cartridge, however the complete assembly has not been verified to demonstrate it provides backflow protection. The inlets of model 28681 incorporate a stainless-steel filter. The inlets of model 28682 incorporate a servicing valve and stainless-steel filter. The outlets of all models incorporate a plastic flow straightener. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Self-closing tap (chromium plated brass) incorporating spring loaded headworks incorporating a dome type operating member, with a single lever operating member controlling the temperature. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate a check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
‘OH RPE’ Range of PE-RT (multi-layer) flexible hoses (white inner/silver outer). The following end connections are available with one or two approved single check valve cartridge(s), however, the complete product has not been fully tested to demonstrate it provides backflow protection: CQC (one) and SQC (one or two). Maximum operating temperature 65°C.
PEX lined flexible hose assemblies with either nylon or stainless-steel braiding and a variety of end connectors. Some models are supplied with screwdriver operated isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
OH Softpex® range of polyethylene lined outlet hoses with stainless steel and polyamide braiding (length 100 to 1000 mm), with various end connections. The hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 65°C.
EPDM lined flexible hose assemblies with either nylon or stainless-steel braiding and a variety of end connectors. Some models are supplied with screwdriver operated isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of indirect and direct unvented storage cylinders consisting of either no coil (GLE) or a factory fitted single (GLC) or twin coil (GLT). The secondary circuit is supplied with a temperature and pressure relief valve set at 7.0 bar@85˚C for 1.0-6.0 bar products and 10.5 bar@95°C for 6.0-10.0 bar products. The products are supplied with an inlet control group (safety kit) consisting of a pressure reducing valve, an expansion relief valve 6.0 bar (1.0-6.0 bar products) or 10.5 bar (6.0-10.0 bar products) and an approved check valve, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Product is also supplied with an expansion vessel. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of free standing direct gas fired unvented cyliners with a enamel coating internal lining and magnesium sacrificial anode. Fitted with a combined temperature and pressure relief valve set at 7 bar. Maximum working pressure 6.5 bar. Maximum operating temperature 80°C.
Range of two, three, four and five-way manifold assemblies incorporating brass bodies (brushed chrome finish) and EPDM ‘O’-rings. The products are supplied with isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of wall mounted, concealed, blending valve, incorporating brass bodies (chrome plated), quarter turn ceramic disc headworks with single lever operating members and a manual diverter diverting the flow to two outlets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Wall mounted, bar type, thermostatic shower blending valves (chromium plated brass), incorporating a quarter turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted bar type thermostatic shower valve, with a ceramic cartridge headwork controlling the flow between overhead shower and handset with a dome type operating member incorporating a manual override button. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a strainer and a single check valve cartridge, however, the complete assembly has not been tested to demonstrate it provides backflow protection. Supplied with hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Concealed, thermostatic shower blending valve, incorporating a brass body and a (chrome plated) functional trim set. The functional trim set comprises of two detent headworks (push to on, push to off) as the main flow control for each shower outlet, a ¼ turn ceramic disc valve with a dome type operating member controlling the flow volume, and a thermostatic cartridge controlling the temperature with a dome type operating member incorporating a manual override button. The functional trim set is also supplied with two brass assemblies comprising of a plastic filter, EPDM ‘O’-rings and an approved check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. These assemblies are to be inserted into the concealed body. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Page 42 of 443
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.