Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes). Incorporating a ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C
Range of wall mounted three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks and various operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic aerators. Maximum working pressure 8.0 Bar. Maximum operating temperature 60°C
Range of expansion vessels with fibreglass bodies and butyl diaphragms. Maximum working pressure: 8.6 Bar. Maximum operating temperature: 23 °C.
Range of in-line carbon block water filters and housings with polypropylene bodies. Maximum working pressure 8.0 bar. Cold water use only.
A range of black polyethylene electrofusion fittings from DN 20 to DN 1200 for use with PE100 and PE100-RC pipes conforming to EN 12201 or ISO 4427. A range of black polyethylene butt-welded fittings from DE 20 to DE 1200 fittings for use with PE100 and PE100-RC pipes conforming to EN 12201 or ISO 4427. Maximum working pressure: 20.0 bar for SDR 9 Maximum working pressure: 16.0 bar for SDR 11 Maximum working pressure: 10.0 bar for SDR 17. For above and below ground and cold water use only.
‘Safety’ range of PPS compression fittings for use with “Multi-Calor” multi-layered PEX/Al/PEX pipe. For above ground use only. Maximum working pressure 10bar. Maximum operating temperature 95 °C.
‘Pexalbrass’ range of brass press fittings for use with “PEXAL” multi-layered (PE-X /Al/PE-X) pipe. Joints are achieved via crimping tool for H (DN16, DN20, DN26, DN32), TH(DN16, DN20, DN26, DN32, DN40, DN50, DN63), U (DN16, DN20, DN26, DN32, DN40, DN50, DN63, DN75, DN90, DN110) profile. Maximum working pressure 10bar. Maximum operating temperature 95 °C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use (sizes 12mm-54mm only. 66.7mm, 76.1mm, 88.9mm & 108mm for above ground use only) Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of PCC type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of CU type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of press fittings (brass bodies - various finishes) with stainless steel press (Unipress MLCP ) collars and EPDM O-rings for use with “EA” range of PEX/AL/PEX multilayer pipe (for press fitting connections and compression for EHA adaptor fittings only) or copper pipe manufactured to EN1057 (compression connections). Maximum operating temperature: 95°C. Maximum operating pressure: 10 bar.
Range of copper solder ring fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass threaded fittings,. Above ground use only. Maximum operating pressure of 16.0 bar. Maximum operating temperature of 85°C.
Supreme range of fittings for use with PE pipes (manufactured to EN12201-2). Supplied with a plastic pipe support liner For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Range of brass (CW617 or CW511L) press fit fittings (M-Type) for use with copper pipe manufactured to EN 1057. Maximum working pressure: 16 Bar. Maximum operating temperature: 99°C.
Tectite Classic and Tectite Pro ranges of copper alloy push-fit fittings The Tectite Classic range is for use with copper tube (manufactured to BS EN 1057) and PEX & Polybutylene tube (manufactured to BS 7291). The fittings are supplied with plastic inserts. The Tectite Pro range is for use with copper tube (manufactured to BS EN 1057). Maximum working pressures & operating temperatures: Tectite Classic fittings with copper pipe: 6.0 bar @ 95°C, 16.0 Bar cold water use. Tectite Classic fittings with PEX & Polybutylene 6.0 bar @ 95°C, 12.0 Bar cold water use. Tectite Pro fittings (15mm - 28mm): 6.0 bar @ 95°C, 20.0 Bar cold water use. Tectite Pro fittings (32mm - 54mm): 6.0 bar @ 95°C, 16.0 Bar cold water use.
Range of stainless steel (SS316L) pressfit fittings with EPDM ‘O’-rings for use with stainless steel pipe (manufactured to EN10312). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of copper crimped fittings with EPDM ‘O’-rings for use with copper pipe manufactured to EN1057. For above and below ground use. Maximum working pressure 16 Bar. Maximum operating temperature 99°C.
Range of copper end feed fittings for use with copper tube to EN 1057. For above and below ground use. Maximum working pressure: 6mm-54mm 16.0bar, 64mm-108mm 10.0bar. Maximum operating temperature 85°C
WC dual flush valves with a plastic body and incorporates an internal overflow. Cold water use only.
WC dual flush valves with a plastic body and incorporates an internal overflow. Cold water use only.
Range of water meters with plastic bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of electromagnetic water meters with stainless steel bodies and natural rubber liners. Maximum working pressure 10.0 Bar Maximum operating temperature 50.0°C
Range of in-line single jet water meters with brass bodies. Products incorporate plastic strainers. Maximum working pressure: 16.0 Bar. Maximum operating temperature: 85.0°C.
Range of in-line water meters with brass or plastic bodies. Models with a minimum length of 130mm and a maximum operating temperature of 50°C are supplied with an optional, non-return valve to be fitted by the installer (not suitable for backflow protection). Maximum working pressure 16.0 bar. The meters can be supplied with a maximum operating temperature of 50°C or 70°C.
Range of water meter manifolds with plastic bodies. The inlets incorporate a spherical valve. Models ending in ‘CGDM’ incorporate a single check valve cartridge and models ending in ‘CGDCVDM’ incorporate two, single check valve cartridges however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds incorporated into a meter chamber. The inlet of all models incorporates an isolation valve and an approved check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection. MK7000003003 is for use with MDPE plastic pipe (manufactured to BS EN 12202-1:2011). Maximum working pressure 12.5 bar. Cold water use only.


Self-priming single stage pump, with stainless steel body, plastic impellers, stainless steel shaft, NBR 'O'-rings and seals. Maximum working pressure 6.0 bar. Maximum operating temperature 45°C.
Range of pumps with plastic bodies, pistons and TPE diaphragm. For use with John Guest LLDPE pipe. The products incorporate non-return valves (not suitable for backflow protection). Maximum working pressure: 8.27 Bar. Cold water use only.
Range of horizontal multistage pumps with stainless steel bodies, diffuser and impellers and EPDM ‘O’-rings. The products incorporate a graphite-SiC-EPDM shaft seal. The products incorporate a drain plug. Maximum working pressure 8.5 bar. 9Maximum operating temperature 80°C.
Range of cold-water supply booster sets, incorporating a stainless-steel manifold system and between 1 and 3 pumps. The booster sets also incorporate spherical valves, non-return valves (not suitable for backflow protection), pressure switches/sensors and expansion vessels. Maximum working pressure: 16.0 Bar. Cold water use only.
Range of multistage and single stage water pumps with stainless steel bodies and impellers. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C
Range of multistage and single stage water pumps with stainless steel bodies and impellers. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C
Range of overhead showers incorporating ABS (plastic bodies - various finishes), stainless steel strainer and flow restrictor (flow restrictor only on “minus flow” models) in the inlets. Open outlet use only. Maximum operating temperature 60.0°C
Range of overhead shower outlets with (brass bodies – various finishes) incorporating stainless-steel filter washers at the inlet. Maximum operating temperature 85°C.
Range of shower outlets with brass bodies (various finishes) and NBR ‘O’-rings. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of overhead shower outlets with brass bodies (various finishes). The inlet incorporates a plastic flow regulator and stainless steel strainer. Maximum operating temperature 60°C
Range of shower handsets with plastic bodies incorporating an integral filter. The inlet incorporates a combined washer and a strainer, plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C. Open outlet use only.
Range of Y-pattern strainers with DZR brass bodies and stainless steel strainers. The compression connection is for use with copper pipe to BS EN1057. Maximum working pressure 20 bar (BSP threaded models ½”-2”), 16.0 bar (compression models). Maximum operating temperature 85°C.
Range of In-line ‘Y’ patterned strainer with ductile iron bodies (blue epoxy powder coated) and stainless-steel screens. Maximum working pressure 16.0 bar. Maximum operating temperature 85ºC.
Range of nylon braided PEX lined flexible hose assemblies with EPDM washers and ‘O’-rings with a variety of end connections. Maximum operating temperature 65.0°C
Range of shower hoses, with either a interlocked stainless steel outer hose (PVC or PEX inner hose - YHR01-A-A-**-**-**& YHR02-A-A-**-**-**); or a PVC outer hose (YHR03-A-A-**-**). Open outlet use only. Maximum operating temperature 65°C.
Range of stainless steel interlocked or PVC reinforced (see models), PVC inner lined flexible hose assemblies (various finishes). Open outlet use only. Maximum operating temperature 65°C.
Range of PVC shower hoses with EPDM O-rings. Maximum operating temperature 65°C. Open outlet use only.
Range of plastic braided PEX lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies with EPDM seals, available with a variety of end connections, some of which include isolation valves (see model). For use with: Copper Pipes manufactured in accordance with BS EN 1057 Plastic PB pipes manufactured in accordance with BS 7291-2 Plastic PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure: 6.0 bar @ 65°C Maximum working pressure: 12.0 bar @ 20°C
Nimbus Compact range of combination heat pump units with enamel lined tank and stainless-steel coil. Fitted with a magnesium anode, expansion vessel and T&P valve set at 7 bar & 95°C. supplied with an inlet control group consisting of a pressure reducing valve, strainer, pressure relief valve and single check valve, and a tundish. Max working pressure 6.0 Bar Max operating Temperature 80 °C
Range of stainless steel hot water buffer tanks. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.
Range of unvented storage cylinders. The secondary circuit is fitted with a temperature and pressure relief valve set at 7.0 bar at 90˚C and an expansion relief valve set at 6.0 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Also Supplied with an expansion vessel and tundish. Maximum working pressures: Primary circuit: 5.5 bar Secondary circuit: 6.0 bar Solar circuit:6.0 bar Maximum operating temperature 85.0°C
Page 31 of 46
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.