Range of spout outlets with (brass bodies - various finishes), incorporating an plastic aerator. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 60°C
Range of expansion vessels with a butyl membrane. Maximum working pressure 10 bar. Maximum operating temperature 99°C
Filling loop assemblies consisting of a stainless steel braided EPDM lined flexible hose, an isolation valve and another isolation valve incorporating a non-verifiable double check valve assembly, verified by test (suitable for backflow protection against fluid category 3). The 171293 model is supplied with an isolation valve including a dial type pressure gauge. The 171292 model is also supplied with brass end caps incorporating EPDM washers. For use with coper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Rigid filling loop assembly, consisting of a lever operated brass spherical valve and a DZR brass double check valve assembly (verified by test as suitable for backflow protection against Fluid Category 3) that incorporates a lever operated spherical valve. For use with copper manufactured to BS EN 1057. Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Non-metallic materials and components comply with BS6920 at 85°C
Filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (which incorporates an isolation valve), verified by test (suitable for backflow protection against fluid category 3). Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Non-metallic materials and components comply with BS6920 at 85°C
Range of water filters comprising of plastic filter heads and plastic filter cartridges. Maximum working pressure 5.0 bar. Cold water use only.
Range of water filters comprising of plastic filter heads and plastic filter cartridges. Maximum working pressure 5.0 bar. Cold water use only.
The “TH Instantor” range of press fittings and pipe. Fittings incorporate EPDM ‘O’-rings Maximum working pressure 10 bar. Maximum operating temperature 95°C
‘Unidelta’ brass compression fittings for use with ‘Unidelta UniTerm’ PEX pipe. Maximum working pressure 8.0 bar @ 85°C, 20.0 bar @cold water use.
Range of solder ring brass fittings for use with copper tube (manufactured to EN 1057) with EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring copper fittings for use with copper tube to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of plastic push-fit fittings (available in black, white and grey) and a manifold (available in grey only) with EPDM or NBR ‘O’-rings. For use with copper pipe (manufactured to EN1057), PE-X pipe (manufactured to BS7291-3:2010) & PB pipe (BS EN 21003-2:2008). Maximum working pressure: 12.5 bar @ 20°C (Cold water use only). From September 2023 the products are suitable for 8.0 bar @ 65°C.
Range of end feed copper fittings for use with copper tube to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). Incorporates an EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The HLDPMFWT and HLDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of water meters with brass bodies, plastic turbines and EPDM washers. Inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of in-line ultrasonic water meters with DZR brass bodies. The following sizes only include a plastic strainer, DN15 - DN32 sizes (incorporated), DN40 size (optional). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Ultrasonic water meter with a brass body. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Water meter manifold with a DZR brass body, NBR ‘O’-rings and incorporates a spherical valve. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 80°C
Range of single or manifold below ground meter boxes. The boxes incorporate a concentric water meter manifold and a servicing valve on each connection. CV models incorporate an approved single check valve cartridge and the DCV model incorporates two approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The pushfit inlet and outlet connections are supplied with pipe inserts and are for use with MDPE pipe (manufactured to EN 12201). Maximum working pressure 16.0 bar. Cold water use only.
Page 220 of 509
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.