Range of inline water filter cartridges with polypropylene housing with a carbon block filter. Maximum working pressure 8.5 Bar Cold water use only.
Range of inline water filter cartridges with polypropylene housing with a carbon block filter. Maximum working pressure 8.5 Bar Cold water use only.
Range of hand wash and dryer units The flow is controlled by a solenoid valve activated via an infra-red sensor. The products are supplied with a non-verifiable double check valve assembly (suitable for backflow protection against Fluid category 3) for installation on the inlet. The double check valve assembly also incorporates a drain port, (located in between the cartridges), and an integral spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 50ºC.
Handshower with a chrome plated plastic body. The inlet incorporates a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Dolphin Blue range of handheld shower outlets with a stainless bodies (various finishes) and EPDM ‘O’-rings. The inlet incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 85°C
Shower handsets (chromium plated ABS) with stainless steel strainers and a built-in approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Range of wall mounted shower elbows with brass bodies (chrome plated) incorporating single check valves cartridges fitted on the outlet (however, the complete product has not been fully tested to demonstrate it provides backflow protection).Maximum operating temperature 65°C.
Concealed installation set for use with wall mounted overhead shower outlets (brass body – various finishes). The inlet to the shower outlet incorporates a stainless-steel strainer, a plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower handsets with plastic body (various finishes). The inlet incorporates a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower heads with plastic bodies and a brass inlet connection. The inlet of the shower head incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 70°C.
Range of bib taps with DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Bib tap incorporating brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted bib taps (brass bodies) with a rising spindle headwork and ‘T’ type operating member. The spout outlets incorporate a hose union spigot connection. The inlets and outlets of models D2034.G15 and D2034.G20 incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of bib taps incorporating brass bodies. The S0311BL-1 and S0311BL-2 models incorporate an approved single check valve cartridge on the inlet and the outlet (hose union), however, the complete product has not been fully tested to demonstrate it provides backflow protection. The S0311BL-1 and S0311BL-2 models also incorporate a drain port. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of bib taps incorporating brass bodies. The BTHUCV1/2 and BTHUCV3/4 models incorporate an approved single check valve cartridge on the inlet and the outlet (hose union), however, the complete product has not been fully tested to demonstrate it provides backflow protection. The BTHUCV1/2 and BTHUCV3/4 models also incorporate a drain port. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Pillar tap incorporating a ceramic cartridge headwork (chrome plated brass body) with a single lever operating member. The spout outlet incorporates a flow straightener and flow regulator. The product is supplied with plastic backnuts Maximum working pressure 10 bar. Maximum operating temperature 60°C
McDonald Steel Flow ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Range of wall mounted thermostatic blending valves with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks and single lever operating member. The temperature is controlled independently via a thermostatic cartridge, single lever operating member and a manual override button. Inlets incorporate a strainer and single check valve cartridges however the complete assembly has not been tested to verify it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of manually operated, wall mounted, concealed blending valves with brass bodies (various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of manually operated, wall mounted, concealed blending valves with brass bodies (various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member and self-cancelling diverter. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Page 22 of 139
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.