`Groundbreaker Mk3` water meter box incorporating a concentric water meter manifold (plastic body) with screw down stop valve, single check valve (verified by test as suitable for backflow prevention up to fluid category 2) & compression fittings. The product is intended to be installed upon the external wall of a premises and incorporates internal insulation (insulation not verified by test). For use with MDPE pipe (manufactured to EN12201). Maximum working pressure 12.0 bar. Cold water use only.
Thermostatic element with copper shell, polyethylene tube and PTFE gasket. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of threaded fittings with either plain brass, nickel plated brass or chrome plated brass bodies. Maximum operating pressure 16.0 bar. Maximum operating temperature 99°C.
Wallgate CWC Series 250 WC pan with direct acting flush valve and DFKIT03 air break (DC device). WC flushing mechanism has a solenoid valve controlling the flow, the valves are operated via an infrared sensor or a piezo control button, this mechanism is fitted with a DC pipe interrupter, the DFKIT03 is fitted with a flow regulator. Maximum working pressure 2.0 bar. Cold water use only.
Shower kit, intended for use with ovens, incorporating a triple layered hose on a reel and a push-button operated shower handset. The inlet of the shower handset incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 4.0 bar. Cold water use only.
Range of circulation valves and flow sensor valves with EPDM seals and O-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 90ºC.
Range of concealed bathroom boxes with extractable shower hoses. The inlet attached to the concealed box incorporates an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet of the shower hose also includes a stainless steel strainer. Maximum operating temperature 60°C.
Range of pressure transmitters with stainless steel bodies. Maximum working pressures: DST-P140 model 25.0 bar, all other models 50.0 bar. Maximum operating temperature 90°C.
Range of pumps with either brass or stainless-steel bodies, stainless steel impellor and NBR ‘O’ rings. 20 & 33 brass series have a maximum working pressure of 16.0 bar. 33 stainless-steel series has a maximum working pressure of 20.0 bar. 22, 24 ,26, 38, 31, 32 & 34 series have a maximum working pressure of 20.0 bar. Cold water use only.
Wall mounted shower intake, having a brass body (chrome plated). The outlet incorporates a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection) Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of shower outlets incorporating brass bodies (various finishes). Maximum operating temperature 60°C.
Range of wall or ceiling mounted shower arms with brass bodies (various finishes). Maximum operating temperature 65°C.
Shower outlets, with NBR and EPDM ‘O’-rings and silicone nozzles. The shower handset has a plastic body with a chrome plated brass outer body and the overhead shower outlet and shower arm have chrome plated brass bodies The inlet of the shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the overhead shower consists of socket and ball joint. The inlets of both products incorporates a combined NBR gasket and stainless steel strainer. Maximum operating temperature 60°C.
Shower kit comprising of a stainless-steel, interlocked shower hose, chrome plated, plastic shower handset and riser rail. Maximum operating temperature 85°C.
Range of overhead shower heads and arms incorporating brass or ABS body. The inlet of models KSAB4K and HEAH06BK incorporates a stainless-steel strainer and plastic flow regulator. Maximum operating temperature 60°C.
Range of wall or ceiling mounted overhead shower outlets (chromium plated brass) and shower arm. Maximum operating temperature 60°C.
Range of shower outlets with chromium plated bodies with check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only. From July 2023 can also be supplied without the check valve at the inlet.
Range of shower outlets with chromium plated bodies with check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
Range of shower outlets with chromium plated bodies with check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
Range of shower handsets and shower heads with chrome plated bodies and built in flow restrictors. Maximum operating temperature 60°C.
In-line, Y-patterned strainer with stainless steel body and EPDM ‘O’-ring. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of in-line “Y” patterned strainers with brass bodies incoroporating NBR ‘O’-rings and stainless steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of inline strainers incorporating DZR brass bodies and a stainless steel mesh. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of flow switches with brass bodies incorporating EPDM ‘O’-rings, acting as a leak detection system that actuates an integral spherical valve to shut off the water supply. The inlet incorporates a stainless steel strainer. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 30°C.
Drain cock elbow incorporating a DZR brass body with EPDM ’O’-rings (ZELB250445 model) or NBR ‘O’-rings (ZELB250446 model added July 2022). Both models are for use with copper pipe (manufactured to BS EN 1057). Maximum working pressures: ZELB250445 model - 10.0 Bar. ZELB250446 - 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps with brass bodies (chromium plated) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chrome plated brass) with quarter turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of stainless steel or ACB braided, PE-RT lined flexible hose assemblies, incorporating various end connections. The 15mm & 22mm compression models may incorporate an isolation valve. The 15mm pushfit incorporates an isolation valve. Models added April 2022 have a maximum operating pressure of 6.0 bar, a maximum operating temperature of 65°C and are for use with copper pipe manufactured to BS EN 1057. All other models have a maximum operating pressure of 10.0 bar and a maximum operating temperature of 85°C
‘Platinox SLP’ range of stainless steel braided silicone lined flexible hose assemblies with a variety of end connections (see size). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of stainless steel, interlocked shower hoses with EPDM liner and O-rings. Open outlet use only. Maximum operating temperature 70°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies with various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Advance Appliance ranges of direct, indirect, solar direct and solar indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar 95°C, an inlet manifold consisting of an in-line pressure reducing valve adjustable between 2.7 & 3.3 bar (but factory set @ 3.0 bar), an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), a pre-set expansion relief valve set at 6.0 bar and a strainer. The product is supplied with a tundish. Maximum supply pressure to pressure reducing valve is 10.0 bar. Maximum working pressure Primary circuit 6.0 bar. Maximum working pressure Secondary circuit 5.5 bar. Maximum operating temperature 85˚C.
Range of 2, 3 and 4 port manifold assemblies with either DRZ brass or brushed chrome plated brass bodies incorporating screw down isolation valves with dome type operating members. Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Range of 2, 3 and 4 port manifold assemblies with brass bodies (brushed chrome finish). The products are supplied with isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
502 series of automatic air venting valves with brass bodies, plastic float and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 115°C. Model added September 2021 (501500) has a maximum operating temperature of 120°C. All other models have a maximum operating temperature of 115°C.
Wall mounted concealed thermostatic shower valve, with a single sequential headwork controlling both flow and temperature. A manual diverter controls the flow between a shower handset or overhead shower. The inlets incorporate a single check valve however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C.
Range of wall mounted, concealed, manual blending valves (chromium plated brass) incorporating a ceramic cartridge headwork, with a single lever operating member, controlling both flow and temperature. Model 36011660 is supplied with a shower hose and handset. The outlets incorporate an approved check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, manually operated blending valves with brass bodies (various finishes), incorporating ceramic cartridge headworks with either single lever (6900XX/METAL only) or dome type (all other models). The product is supplied with a shower hose and handset. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of wall mounted concealed shower valves (chromium plated brass) incorporating a ceramic cartridge headwork with single lever operating member. The shower outlet incorporates an approved single check valve cartridge however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection. Products are supplied with overhead shower outlet and shower hose. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted manually operated, concealed blending valves (cast brass body) with a ceramic cartridge headwork controlling both flow and temperature with as single lever operating member and a manual diverter to shower outlets with a single lever operating member. Maximum operating pressure 5.0 bar. Maximum operating temperature 65°C.
Range of ‘right hand’ or ‘left hand’ tempering valves having a plastic body incorporating a thermostatic element. The cold inlet incorporates a single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic mixers incorporating a brass body (chromium plated) and ceramic disc headwork with dome type operating members The temperature is controlled independently via a thermostatic cartridge with dome type operating member and manual override button. Both inlets incorporate a stainless steel strainers and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Model 1.1900.018 is supplied with a shower handset and riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted thermostatic mixers incorporating brass body (chromium plated) and ceramic disc headwork with dome type operating members The temperature is controlled independently via a thermostatic cartridge with dome type operating member and manual override button. Both inlets incorporate a stainless steel strainers and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Products are supplied with a shower hose, shower handset and shower rail. Maximum working pressure 5.0 bar. Maximum operating temperature 45°C.
Range of wall mounted thermostatic shower valves incorporating chrome plated brass bodies. Product is supplied with a shower hose, handset and riser rail and over head shower. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C.
Wall mounted, exposed, thermostatic bar type shower mixing valve (chromium plated brass) incorporating a quarter turn ceramic disc headwork with a dome type operating member, which controls the flow to a top mounted outlet. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a combined NBR washer and stainless steel strainer and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
T-type thermostatic mixing valves with chromium plated brass bodies. The inlets incorporate a stainless-steel strainer and an approved single check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets of model MT753CP-ISO also incorporate an isolation valve, Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Wall mounted thermostatic bar type shower valve incorporating a ceramic cartridge headwork, with single lever operating member, which controls and diverts the flow between the two shower outlets. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member which incorporates a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of butterfly valves with a plastic body, PVDF disc & EPDM sealing ring. The closing mechanism is controlled by a single lever operating member. Maximum working pressure 16.0 Bar. Maximum operating temperature 80°C. Maximum working pressure: (DN200 - 250): 10.0 bar (DN300): - 6.0 bar
Range of handwheel operated butterfly valves with blue epoxy coated ductile iron bodies and discs, and EPDM seals. Maximum working pressure 10.0 or 16.0 bar (see model). Maximum operating temperature 65°C.
Range of wall mounted flow control valves and trim kits (various finishes) with brass bodies incorporating a quarter turn ceramic disc headwork with various operating members (see model). The outlet of all models, except for the 38 882 xxx AXOR Uno model, incorporates a single check valve cartridge, (verified by test suitable for backflow protection against Fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Page 21 of 225
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.