Spring loaded, resilient trim, in-line check valve cartridges, with plastic guides and jumper and NBR rubber seals within a plastic housing. For insertion in pipes and fittings with specifically sized bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Spring loaded in-line check valve cartridge with plastic guides, plunger & housing and NBR rubber seals. For insertion in pipes and fittings with specifically sized bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spring loaded, resilient trim, in-line check valve cartridges with plastic guide, stem and body with silicone or EPDM 'O'-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C for models 30.4010.0 and 40.4011.0. Maximum operating temperature 60°C for models 30.4043.0 and 30.4094.0.
Spring loaded, resilient trim, in-line check valve cartridge with plastic guide, stem, body and EPDM O-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Spring loaded resilient trim in-line check valve cartridge with plastic guide, stem and housing, stainless steel spring and EPDM ‘O’-rings. For insertion into specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spring loaded, resilient trim, in-line check valve cartridge, with plastic guides & jumper and NBR or EPDM seals within a plastic housing. For insertion in pipes and fittings with specifically sized bores. Maximum working pressure 16.0 bar. Model 31.4220.0. has a maximum operating temperature of 85°C. Model 31.0003.0 has a maximum operating temperature of 60°C.
Range of spring loaded, resilient trim, in-line check valve cartridges, with plastic guides & plunger and EPDM or Silicone seals within a plastic housing. For insertion in pipes and fittings with specifically sized bores. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C
Range of spring loaded, resilient trim, in-line check valve cartridges with plastic guide, stem and body with NBR or EPDM 'O'-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C for model NV15/DN15-EPDM 31.0002.0. All other models have a maximum operating temperature of 85°C.
Adaptor, with DZR brass body (chrome plated), which incorporates a single check valve cartridge verified by test (as suitable for backflow protection against Fluid Category 2). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of non-verifiable double check valve assemblies with DZR brass bodies, incorporating two spring loaded, resilient trim in-line check valve cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-verifiable double check valve assembly incorporating DZR brass (chrome plated) body two spring loaded, resilient trim in-line check valve cartridges & a drain port located between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of non verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body. The products incorporate a drain port between the cartridges. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of non-verifiable double check valve assemblies, consisting of two spring loaded resilient trim in-line check valve cartridges housed in DZR brass bodies (brushed chrome plated) with a drain port located between the cartridges either at the top or bottom. Models incorporate an isolation valve with either lever or butterfly handles. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of non-verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body, compression models are nickle plated. A drain port is provided between the cartridges. Compression models are to be used with copper pipe to EN1057. Maximum working pressure 16.0 Bar. Maximum operating temperature for the D220W range 85°C. Maximum operating temperature of the D200CW range 60°C.
‘Parker 500’ assisted bathing unit. Flow is controlled via a thermostatic mixing valve, the inlet of which incorporates a stainless steel strainer and single check valve cartridge (suitable for backflow protection against Fluid Category 2) and feeds either a bath spout outlet or shower handset which incorporates a self-closing trigger. The inlet to the shower handset incorporates a plastic flow restrictor and a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. There is a combined spherical valve and strainer on the inlet to the bathing unit which incorporates a single check valve cartridge (suitable for backflow protection against Fluid Category 2). The ‘shepherds crook’ type shower outlet is protected via an AUK3 airgap arrangement. Maximum working pressure 6.0 bar. Maximum operating temperature 80°C
Range of single hole, single outlet (fixed) over the rim (swivel nozzle) bidet combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork and either single lever or dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C
Range of ceramic cartridge headworks with a plastic body and EPDM ‘O’-rings to be inserted into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ceramic disc headworks with brass bodies and EPDM seals. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks incorporating plastic bodies and silicone ‘O’-rings, to be inserted into specifically dimensioned bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 70°C.
Range of ceramic cartridge, ceramic disc, non-rising spindle, or push button cartridge (see models) headworks to be installed in specifically dimensioned bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 65°C.
Range of ceramic cartridge headworks with NBR ‘O’-rings and silicone seals or silicone ‘O’-rings and seals (depending on model). For insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Models 35H-F, 40D-F & 40H-F have a maximum operating temperature of 60°C. All other models have a maximum operating temperature of 85°C.
Range of ceramic cartridge headworks with plastic bodies incorporating silicone seals for insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Ceramic cartridge headwork with plastic body and silicone seals, for insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with plastic bodies and silicone ‘O’-rings and gaskets for insertion into specifically dimensioned tap assemblies. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Manually operated 2-way diverter valve headwork, with a plastic body and silicone seals. To be inserted into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Manually operated 2-way diverter valve headwork, with a plastic body and silicone seals. To be inserted into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Range of thermostatic cartridges with plastic bodies, stainless steel strainers and EPDM ‘O’-rings. For insertion into specifically dimensioned tap bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C
Range of CA43 thermostatic cartridges incorporating plastic bodies and stainless steel filters. For insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass). incorporating a ceramic cartridge and single lever operating member with a spring loaded, pull down trigger operated spray. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a click type waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 70°C.
Range of single hole, single outlet, fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating members. The spout outlet incorporates a plastic aerator and the product is supplied with either a lever or click type pop up waste (see models). Maximum working pressure 5.0 bar. Maximum operating temperature 60.0°C
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes, see model). Incorporating ceramic cartridge headworks, and single lever operating members. The inlets incorporate flow strainer and the spout outlet incorporates a plastic flow straightener. Can be supplied with our without a pop up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with single lever or dome type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate either a plastic flow straightener or aerator. The product is supplied with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with either a dome type or single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure is 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straighteners Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Single hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating. The spout outlet incorporates a plastic flow straightener. Product is supplied with a pop up waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (in black or chrome finishes) with brass bodies. Incorporating ceramic cartridge headworks, and single lever operating members. The spout outlet incorporates a plastic aerator. Some models are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly incorporating ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Models 53003 and 53005 are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating members. The spout outlet incorporates a plastic flow straightener. Products are supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Products are supplied with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets of models SAVV2313 & SEV313 incorporate a plastic aerator, model SPA2113/EX incorporates a stainless steel filter. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes), incorporating a ceramic cartridge headwork with a single lever (Absolute range) or dome type (Engineer & Illustrious range) operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60.0°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator and the inlets incorporate a stainless steel strainer. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener with an optional aerator. Fittings are supplied with a pop-up waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener and the product is supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet of model 825JK incorporates a plastic aerator. Products are supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Page 1 of 56
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.