‘POD’ range of indirect and direct heat interface units providing space heating and instantaneous hot water. The heat transfer is generated via plate heat exchangers. The domestic hot water (DHW) circuit incorporates an adjustable temperature mixing valve. The indirect models incorporate an expansion vessel (on the CW inlet of the DHW circuit) and a pressure relief valve set at 3.0 bar (on the space heating circuit). The indirect models only are supplied with a temporary filling loop, which comprises of a stainless steel braided EPDM lined flexible hose assembly and a lever operated spherical valve for connection to the primary circuit. The angled cold water inlet incorporates an isolation valve and a branch to connect to the filling loop, which includes a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3). Maximum working pressure for indirect units: Primary circuit: 16.0 bar. Space heating: 2.5 bar. Secondary circuit (DHW): 10.0 bar. Maximum working pressure for direct units: Primary circuit: 10.0 bar. Space heating: 10.0 bar. Secondary circuit (DHW): 10.0 bar. Maximum operating temperature for domestic hot water 65°C. Maximum operating temperature for central heating and primary circuit 85°C.
Range of wall mounted, gas-fired, condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and a pressure relief valve set at 3.0 bar. The inlets to the domestic hot water and primary circuits each have a screwdriver operated angled spherical valve. Both include a ½” BSP (M) connection for a filling link. The Greenstar CDi models only are supplied with an integral charging link (CAB device) verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature of primary circuit is 82°C. Maximum operating temperature of secondary circuit is 60°C.
Hydraulic block assembly comprising of a flow regulator, central heating pump assembly and a stainless-steel plate heat exchanger. Maximum working pressures: DHW circuit: 10.0 Bar Central heating circuit: 2.5 Bar Maximum operating temperature: DHW Circuit: 65.0°C Central heating circuit: 90.0°C
Range of commercial ice making machines with flow controlled via solenoid valve. Maximum working pressure 8 bar. Cold water use.
Range of water meters with blue epoxy coated iron bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Permanent filling/ pressurisation device for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. In the event of a fall in system pressure, and only if the mains pressure is adequate, a solenoid valve operates to allow water into the system. At all other times a second solenoid valve drains the fill chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Maximum working pressure 6.0 Bar. Cold water use only.
Range of pressure transmitters with stainless steel bodies. Maximum working pressure 10.0 to 200.0 bar (please refer to model). Maximum operating temperature 100°C.
Range of brass (chrome plated) quick fit connectors. Maximum operating temperature 60°C
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (46553 - Stuart CH 4-30 & 46554 - Stuart CH 4-40 models) or 9.0 bar (46555 - Stuart CH 4-50 &46556 - Stuart CH 4-60 models). Maximum operating temperature 65°C.
Range of booster pumps with stainless steel bodies, plastic impellers, and NBR ‘O’-rings. The products incorporate a temperature sensor, pressure sensor, pressure vessel and a non-return valve integral to the pump chamber. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C.
Range of brushless DC centrifugal pumps with a plastic body. Maximum working pressure 1.0 Bar. Maximum operating temperature 70°C.
Range of single and twin shower booster pumps with brass bodies, DZR brass impellers, NBR ‘O’-ring and EPDM seals. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Ranges of overhead shower outlets with brass bodies, chrome plated plastic shower handsets, shower sets and shower kits. The shower sets comprise of a chrome plated plastic shower handset and shower hose. The shower kits comprise of a chrome plated plastic shower handset, brass wall elbow and either stainless steel interlocked, or PVC coated, shower hoses. The inlets of the shower handsets incorporate a plastic flow regulator at the inlet. Shower kits with ½” (M) inlets are also supplied with a brass wall elbow which incorporate a plastic flow regulator and an approved single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum operating temperature 60°C.
Range of shower outlets (celing or wall mounted arms - see model) with chrome plated brass bodies and silicone nozzles. The products incorporate a swivel joint connection to the shower head which incorporates a combined NBR washer and stainless steel strainer. All models, except for the 15199 model, include a plastic flow regulator on the inlet to the shower head. Maximum operating temperature 60°C.
Range of overhead shower outlets with brass bodies (various finishes, see model), incorporating stainless steel strainer and flow regulator on the inlets. Maximum operating temperature 60°C.
Range of shower handsets with plastic bodies incorporating an integral filters. The inlet incorporates a combined washer and a strainer, plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Wall mounted overhead shower outlets with (chrome plated) brass bodies and EPDM ‘O’-rings. Maximum operating temperature 65°C.
Range of shower arms, ceiling arms, water intakes and wall mounted outlet brackets (all models excluding INOX are chrome plated brass, INOX models are stainless steel). Maximum operating temperature 60.0°C
Overhead shower outlet with a chrome plated plastic body. The inlet incorporates a stainless-steel strainer. Maximum operating temperature 65°C.
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. The 1BCB001 & 1BCB701 models incorporate two approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.
Range of pillar taps with brass bodies (various finishes) incorporating non-rising spindle headworks using either dome type or cross top operating members. Spout outlets incorporate plastic flow straighteners. The products are also supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of pillar taps with brass bodies (chrome plated), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener or aerator. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating pressure 85°C.
A range of wall mounted self-closing pillar taps or shower valves (chromium plated brass), incorporating a spring loaded headwork with a dome type operating member. The spout outlet incorporates a plastic aerator Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of deck mounted self-closing pillar taps (chromium plated brass), incorporating a spring-loaded headwork with a dome type operating member. The spout outlet incorporates a plastic flow straightener. During January and February 2022, the products are supplied with metal back nuts. From March 2022, the products are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
A range of wall mounted self-closing pillar taps or shower valves (chromium plated brass), incorporating a spring loaded headwork with a dome type operating member. T Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of self-closing taps with chromium plated brass bodies, incorporating a non-concussive headwork with or without operating members (see model). The GR 120 + GR 138 + GR 100 model represents three parts which must be installed together to create one complete product. It comprises of a gooseneck spout (chromium plated brass) (GR 120), a single self-closing side valve (brass) incorporating a stainless steel strainer on the inlet (GR 138) and a loose inlet tee piece (chromium plated brass) (GR 100). The inlets of the GR 102M model and the GR 100 tee piece incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. All models, except for the GR 102M model, are supplied with metal back nuts. All spouts incorporate a plastic flow straightener. The GR102M model incorporates a manual temperature control operated by a single lever on the side of the body, on all other models this is achieved via an adjustment plug in the base of the tee piece. Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
‘Tempomix 3’ range of self-closing combination tap assemblies (chromium plated brass) with spring loaded headwork controlling both the flow and temperature with a dome type operating member. The spout outlets incorporate a plastic flow straightener. The inlet hoses each incorporate a plastic strainer and a plastic flow restrictor either side of an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The 794000 and 79400015 models are supplied with ⅜” BSP (M) x ⅜” captive nut inline isolation valves. The 79400015 model is also supplied with a ⅜ BSP (M) x ½” BSP (M) brass adaptor. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of shower hoses with PVC outer (various finishes - see model), PET reinforcement layer, PVC inner liner and EPDM washers. Maximum operating temperature 65°C.
Range of stainless steel or nylon braided PEX lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies incorporating EPDM washers and ‘O’-rings, and various end connections, some of which include a brass bodied screwdriver operated spherical valve with chrome plated brass ball (see model). For use with copper pipe (EN 1057) Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies incorporating EPDM washers and ‘O’-rings, and various end connections, some of which include a brass bodied screwdriver operated spherical valve with chrome plated brass ball (see model). For use with copper pipe (EN 1057) Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of EPDM or PVC lined flexible hose assemblies with either nylon braided, or chrome plated interlocking outer layer (see models). Maximum operating temperature 85°C.
Mitsubishi EHWT17D-MHEDW indirectly heated stainless-steel unvented storage cylinder consisting of plate heat exchangers. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of an approved single check valve cartridge (verified by test as suitable for backflow protection against Fluid Category 2), strainer, a pressure relief valve set at 6.0 bar and pressure reducing valve set at 3.5 bar. The space heating circuit is factory fitted with a pressure relief valve fitted rated at 3.0 bar and an automatic air vent. A tundish, expansion vessel and filling loop are also supplied. Maximum secondary (wholesome) circuit working pressure: 5.5 bar. Maximum Space heating (primary) circuit working pressure: 2.5 bar. Maximum brine/ambient circuit working pressure: 9.5 bar. Maximum operating temperature 70°C
‘Comet’ combination units consisting of a cased and insulated stainless steel unvented hot water storage cylinder. The cylinder primary circuit is fitted with an in-line electrical heater which supplies the heat source to the secondary water via a stainless-steel coil, and the heat source to the central heating circuit directly. The cylinder is factory fitted with a temperature and pressure relief valve, pre-set at 7.0 bar 90 degrees. The unit is supplied with an inlet control group containing a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), pressure reducing valve set at 3.0 bar and an expansion relief set at 6.0 bar. An expansion vessel is factory fitted to both the secondary and primary circuits within and is positioned inside the casing. The primary circuit also incorporates a circulating pump and pressure relief valve which is set at 3.0 bar. Maximum secondary working pressure 5.5 Bar Maximum Primary working pressure 2.5 Bar Maximum operating temperature 65.0 °C
Range of 2, 3 or 4 way manifolds with a brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Vacuum relief valve with a DZR brass body. Maximum working pressure 16.0 bar. Maximum operating temperature 99˚C
Wall mounted, exposed, manual blending valve (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member controlling both flow and temperature. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of deck mounted, manually operated, concealed blending valves with chromium plated brass bodies and either brass or stainless-steel trim (see model). The product incorporates a ceramic cartridge headwork with a single lever operating member. The product is supplied with a stainless steel braided PEX lined flexible hose assembly incorporating a ¾” captive nut end connection for installation on the outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Concealed electronic thermostatic shower valve with a plastic body, the flow is controlled via two motorised valves for hot and cold supply. Both inlets incorporate a plastic strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 7 bar. Maximum working temperature 65°C.
Range of concealed thermostatic shower valves with brass bodies incorporating a quarter turn ceramic disc headwork controlling the flow to the shower outlet model VV135-IS incorporates a single shower outlet (x1 headwork) and model V134-IS incorporates a double shower outlet (x2 headworks). The temperature is controlled independently via a thermostatic cartridge. Both inlets incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of concealed, wall mounted, thermostatic mixer valves with brass bodies (various finishes) with 1 - 6 outlets. Flow is controlled to each outlet by ‘detent’ (push to on push to off) headworks. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The inlets incorporate a combined plastic washer and stainless steel strainer, as well as an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model SL-T50004BW has a maximum working pressure of 10.0 bar. All other models have a maximum working pressure of 6.0 bar. Maximum operating temperature is 85°C.
Range of wall mounted, exposed bar type thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork controlling the flow with a dome operating member and manual override button. The temperature is controlled by a thermostatic cartridge with dome type operating member and manual override button. Both inlets incorporate a stainless-steel strainer and single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted exposed thermostatic blending valve (chromium plated brass). Incorporating a thermostatic cartridge which controls both flow and temperature independently with a single lever (flow) and cross top or single lever (temperature) operating members. The flow control incorporates a manual override button. The inlets incorporate stainless steel strainers and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, bar type thermostatic blending valves (chromium plated brass) incorporating a 2-way manual diverter valve controlling and diverting the flow between an overhead shower and a shower outlet with dome type operating members, model (34458892) is supplied with cross-top operating members. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet to the overhead shower incorporates a stainless steel strainers and flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted thermostatic blending valves with brass bodies (various finishes), incorporating a quarter ceramic disc headwork controlling the flow with dome type operating member. Temperature is controlled via a thermostatic cartridge with dome type operating member incorporating a manual override button and a push button manual diverter to shower outlet. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
Range of wall mounted, bar type thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork controlling the flow with a dome or cube operating member incorporating a manual override button. The temperature is controlled by a thermostatic cartridge with dome or cube type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, bar type thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork controlling the flow with a dome or cube operating member incorporating a manual override button. The temperature is controlled by a thermostatic cartridge with dome or cube type operating members incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of wall mounted, bar type thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork controlling the flow with a lever operating member. Temperature is controlled independently via a thermostatic cartridge with a single lever operating member. Both inlets incorporate an eccentric isolation valve, a stainless-steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides back flow protection. The shower outlet connection on the main valve incorporates a flow restrictor (H9741 model only). Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C
Page 70 of 222
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.