Single-hole, single outlet, fixed combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a waterfall type spout outlet. The inlet hoses incorporate a combiner washer and stainless-steel strainer. The products are supplied with two loose brass ½” BSP (M) x ½” BSP (F) adaptors for installation on each inlet hose. These adaptors incorporate an approved single check valve cartridge, verified by test (suitable for back flow protection against Fluid Category 2). The product is supplied with click type pop-up waste. Maximum working pressure 5.0 bar. Maximum working pressure 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The products can be supplied with waste outlets (see models). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Non-metallic materials and components comply with BS6920 at 70°C
Floor mounted single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to a shower outlet. The spout incorporates a plastic flow regulator and the shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. This product is supplied with a shower hose and handset which incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic disc headworks with a single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel), combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout incorporates a push to open, push to close ‘detent’ headwork and the spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. The cold inlet hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic disc headworks with a single lever operating members. The spout outlet incorporates a plastic flow straightener or aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The 33500626 and 33515626 models are supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate a combiner washer and stainless-steel strainer. Maximum working pressure 5.0 bar. Maximum working pressure 60°C.
Single hole, single outlet (swivel) combination tap assembly (brass body, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
A range of single hole, single outlet (swivel) combination tap assemblies (brass bodies, various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The product is also supplied with an alternative spout outlet that incorporates a plastic flow straightener and a stainless-steel strainer. The products are supplied with a loose brass ½” BSP (M) x ½” BSP (F) adaptor for installation on the cold inlet. This adaptor incorporates a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chrome plated), incorporating ceramic cartridge headworks with single leaver operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disk headworks with single leaver operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly with brass body (chrome plated), incorporating quarter turn ceramic disc headworks with a single lever type operating members. The outlet incorporates a plastic flow straightener. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass or stainless steel), comprising of a concealed rough in set with a brass body and a variety of separate trim sets incorporating a ceramic cartridge headwork with a dome type or single lever operating member and a spout outlet. The spout outlet incorporates a plastic aerator. The products are supplied with click type (click clack) waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate either a plastic flow straightener or aerator depending on model. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies with (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet, fixed combination tap assemblies (chrome plated brass), incorporating a single sequential cartridge headwork with a dome type operating member. The spout outlet is connected to the flow control valve via a stainless steel braided PEX lined flexible hose assembly. The spout inlet incorporates a plastic flow regulator, and the spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, wall mounted (fixed) combination tap assemblies with brass bodies (chrome plated), incorporating quarter turn ceramic disc headworks with single lever operating members and manual override button. The products incorporate a manual diverter to a shower outlet with a single lever operating member and the spout outlets incorporate plastic aerator. The products are supplied with a shower handset, shower hose and metal back nuts. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members or non-rising spindle headworks and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (swivel) combination tap assemblies (brass bodies, various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The product is also supplied with an alternative spout outlet that incorporates a plastic flow straightener and a stainless-steel strainer. This product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies incorporating chrome plated brass bodies, quarter turn ceramic disc headwork with lever type operating members. The spout outlets incorporate a plastic aerator. The product is supplied with stainless steel braided PEX lined flexible hose assemblies to connect between the valves and spout Model 23484W-4-CP is supplied with pop up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated) incorporating quarter ceramic disc headworks and various operating members (see model). The spout outlet incorporates a plastic aerator. The product is supplied a click type waste and stainless steel braided EPDM lined flexible hose assemblies for connecting the side body headworks and the spout junction. Maximum working pressure 5.5 bar. Maximum working temperature 60 °C.
Wall mounted three-hole, single outlet (fixed) combination tap assembly with a brass body (chrome plated) incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of wall mounted four-hole, single outlet, fixed, bath shower mixers (chromium plated brass) incorporating a ceramic disc diverter headwork controlling the flow to 2 outlets. The temperature is controlled independently via a thermostatic cartridge with a manual override button. The RAKPES3306C model has cube type operating members and the RAKPER3306C model has dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of five-hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated) incorporating quarter turn ceramic disc headworks with cross top operating members for model (ELW-135) all other models have single lever operating members and a manual diverter to shower outlet. The product is supplied with stainless steel braided EPDM lined flexible hose assemblies to connect between the side valves and spouts. Spout outlet incorporates a plastic flow straightener Product is supplied with a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of basin spout outlets with brass bodies (various finishes), the outlet incorporates either a metal aerators, plastic aerators or open outlet (depending on model). Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Expansion vessels incorporating a stainless steel body and EPDM membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 100˚C.
Range of expansion vessels with EPDM membrane and stainless steel flange connections. Maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
‘Unidelta Deltapress’ range of brass press-fit fittings for use with ‘Unidelta Flexall’ PE-RT/AL/PE-RT pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
‘HE-705X & HE-715X’ ranges of brass crimp fit fittings incorporating EPDM ‘O’-rings for use with copper pipe (manufactured to EN1057-2006). HE-7052/7053/7058/7059 & HE-7152/7153/7158/7159 models also incorporate a NBR gasket. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
VSH XPRESS Range of copper press fittings with EPDM rubber ‘O’-rings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of PVC-u solvent weld and threaded union fittings incorporating an EPDM ‘O’-ring. For use with PVC-u pipe manufactured to ISO 1452 and DIN 8063. Maximum working pressure 10.0 bar. Cold water use only.
‘Xpress’ range of press fit fittings with copper or brass bodies and EPDM ‘O’-rings. For use with copper tube manufactured to EN1057. For above ground ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
‘Endex’ range of copper alloy and copper end feed fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Low profile mechanical seal intended for the internal repair of pipe joints. The system incorporates two stainless steel compression rings and an EPDM seal. For above and below ground use. Maximum working pressure 22.5 bar. Cold water use only.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of gas fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The cold inlet incorporates an angled spherical valve with a brass body, chromium plated brass ball and a lever operating member. The primary circuit incorporates an expansion vessel, isolation valves on flow and return, drain valve and a pressure relief valve set at 3.0 bar. Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature for the secondary circuit is 55˚C. Cold supply only.
Range of air cooled ice making machines . Inlet is controlled via solenoid valve. Maximum working pressure 5.5 bar. Cold water use only.
Range of in-line water meters with brass bodies and plastic inlet filters. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C (SJ & ELECTO-SJ models) Maximum operating temperature 30°C (AP VARIO and AP RADIO models)
Range of water meter manifolds (plastic body). Model WB31520CG incorporates a single check valve cartridge and model WB31520CGDCV two single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 16.0 bar. Cold water use only.
Thermally activated water saving valve with a plastic body and non-return valves on the hot and cold outlet. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Water hammer arrestor with brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Y type fittings incorporating brass body and NBR washer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pump inverters with plastic bodies, NBR rubber and EPDM rubber seals and ‘O’-rings. The products incorporate an inline resilient trim non-return valve. Maximum working pressure 13.0 bar. Cold water use only.
Bypass valve assembly with a plastic body and push/pull operating method to switch flows between different outlets. The product incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Cold water use only.
Page 62 of 222
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.