Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic disc headwork and single lever operating member. The outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating either a ceramic cartridge headwork (models SH2CP/SH2BN), or quarter turn ceramic disc headwork (all other models) and single lever operating members. The spout outlets of all models incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporates a plastic flow straightner. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated stainless steel) incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (swivel) combination tap assemblies with brass bodies (various finishes). Incorporating a non-rising spindle headwork with a dome type operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of single hole, double outlet (swivel) combination tap assemblies (chromium plated brass). All models can be specified with either a non rising spindle headwork or a quarter turn ceramic disc headwork with dome (Tevere), cross top (Monaco) or single lever (Miura) operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic cartridge headworks with dome type operating member. The inlet incorporates a flow restrictor and the spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members or non-rising spindle headworks with cross top operating members (model CR26 & CR26/501). The spout outlet incorporates a plastic flow straightener (models CR26 & CR26/501 do not incorporate a flow straightener). The products are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic flow straightener & stainless-steel strainer. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disk headworks with single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with plastic (model VSN208) metal (model DAR108) backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass & matt black finish) incorporating a quarter turn ceramic disc headworks with single lever operating members and a manually operated diverter to shower outlet. The spout outlets incorporate a plastic flow straightener and the products are supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating three quarter turn ceramic disc headworks controlling the flow and temperature with cross top operating members and a manually operated diverter to shower outlet with cross top operating members. Model T2DB is supplied with a shower handset and hose and model B2TDS is supplied with a shower pipe and arm. The spout outlets incorporate a plastic aerator or flow straightener. Products are supplied with metal backnuts. The inlets incorporate an approved check valve cartridge however, the complete products have not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks controlling the temperature with cross top operating members and a manually operated diverter to shower outlet controlling the flow with cross top operating members. The product is supplied with a shower pipe and arm. The spout outlets incorporate a plastic aerator or flow straightener. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly brass body(in various finishes), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The inlet to the shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic flow straightener and the product is supplied with a shower hose, shower handset and plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or an optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted two hole, double outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc (DLV305B, DLT305B) or rising spindle (CR305 “Bridge”, CR305/501 “Bridge” & GEO305) headworks. Models GEO305, DLT305B and DLV305B incorporate single lever type operating members. Models CR305 and CR305/501 incorporate cross top operating members. The products are supplied with plastic back nuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted two hole, double outlet (swivel) combination tap assembly (chromium plated brass) with quarter turn ceramic disc headworks and single lever type operating members. The product is supplied with plastic back nuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Two hole, wall mounted, double outlet (swivel) combination tap assembly (chromium plated brass). Incorporating rising spindle headworks on the tap body controlling the supply to the pull out hand held pre rinse outlet. An additional rising spindle headwork with a cross top operating member controls the flow to the spout outlet. Maximum working pressure 8.6 bar. Maximum operating temperature 85°C.
Range of two hole, double outlet (swivel) combination tap assemblies (chromium plated brass). All models can be specified with either a non rising spindle headwork or a quarter turn ceramic disc headwork with dome (Tevere), cross top (Monaco) or single lever (Miura) operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Three-hole, single outlet, fixed combination tap assembly with a brass body (various finishes), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator and the products are supplied with lever type pop-up waste and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of three-hole, concealed, metal, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headwork with wheel, dome, cross top or single lever operating members. The spout outlet comes in various lengths and incorporates a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of three hole, deck mounted, single outlet (fixed) combination tap assemblies (various finishes, see model) incorporating quarter turn ceramic disc headwork with either cross top or single lever operating members and interconnecting flexible hoses. The spout outlets incorporate a plastic aerator. Products are supplied with a pop-up waste. Maximum working pressure 4.1 bar. Maximum operating temperature 60°C.
Range of wall mounted three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks and single lever operating members and interconnecting flexible hoses. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating non-rising spindle headwork with cross top operating members and manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener (optional aerator is also supplied) and the product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of five hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headwork controlling the flow to the shower handset and two quarter turn ceramic disc headworks controlling the flow to the spout outlet, all with single lever operating members. The spout outlets incorporate a plastic aerator. The inlet to the shower handsets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of combined bath fillers and overflows with a plastic body and a variety of different trims. The outlet incorporates a plastic flow regulator and the products are supplied with a cable operated pop-up waste. Maximum operating temperature 65°C.
Range of combined bath fillers and overflow waste assemblies with plastic bodies (various finishes). The outlet incorporates a plastic aerator and the product is supplied with a cable operated pop-up waste. Maximum operating temperature 60°C.
Range of cylindrical expansion vessels incorporating butyl rubber diaphragms. The products are supplied with an Airfix TD T piece. Maximum working pressure of model Airfix D 35 litre is 8.0 bar. All other models have a maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
Range of brass caplillary fittings for use with EN1057 copper tube. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of copper solder ring fittings for use with copper tube. For above and below ground use. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of brass compression fittings for use with copper pipe to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of press fittings incorporating copper or copper alloy bodies and EPDM O’-rings for use with copper tube to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
End Feed Range copper fittings for use with copper tube. For above and below ground use Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.
Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.
Range of copper brazed, stainless steel heat exchangers in various sizes (4-300 plates, see model). Models size X8T-SC-S Maximum working pressure primary circuit: 32.0 bar Maximum working pressure secondary circuit: 26.0 bar Maximum operating temperature: 99°C Models size 10T-SC-M Maximum working pressure primary circuit: 41.0 bar Maximum working pressure secondary circuit: 36.0 bar Maximum operating temperature: 99°C Models size 15T-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45 bar Maximum operating temperature: 99°C Models size 16DW-SC-S Maximum working pressure primary circuit: 16.0 bar Maximum working pressure secondary circuit: 16.0 bar Maximum operating temperature: 99°C Models size 16DW-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45.0 bar Maximum operating temperature: 99°C Models size 220-SC-S Maximum working pressure primary circuit: 25.0 bar Maximum working pressure secondary circuit: 25.0 bars Maximum operating temperature: 99°C Models size 320HT-SC-S Maximum working pressure primary circuit: 33.0 bar Maximum working pressure secondary circuit: 29.0 bar Maximum operating temperature: 99°C Models size 320LT-SC-S Maximum working pressure primary circuit: 33.0 bars Maximum working pressure secondary circuit: 29.0 bars Maximum operating temperature: 99°C
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.
RINNAI range of wall mounted combination boilers.The unit incorporates a stainless-steel plate heat exchanger pressure relief valve set at 3.0 bar and an expansion vessel on the primary circuit. Maximum working pressure of primary circuit is 2.5 bar and secondary circuit is 10.0 bar. Maximum operating temperature 60˚C.
Hydroblock unit consisting of a stainless steel heat exchanger, a pressure relief valve pre-set at 3.0 bar, diverter valve and return valve. Maximum working pressure 2.5 bar. Maximum operating temperature 90°C
Hygienic flush box providing a timed flush facility. The supply is via a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection, flow sensor, spherical ball valve and strainer. The products incorporate a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The units have multiple interface user functions for timed flush, wireless technology and data storage. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Maincor Manifold having a brushed chrome plated body with 2 ,3 or 4 ports each with an isolation valve with red or blue indicators for hot and cold feeds. Supplied with a blanking plug and nut. Maximum working pressure 6.0 bar. Maximum operating temperature 75°C.
Range of in-line plastic flow regulators. The flow regulator is housed within a black plastic body incorporating a plastic strainer and an EPDM ‘O’-ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of water monitoring systems comprising of a battery or mains operated latching solenoid valve (plastic body) and a flow sensor. The units are supplied with a hand-held controller. Maximum working pressure 10.0 bar. Cold water use only.
Range of flow measurement devices (DZR brass) bodies incorporating two test ports. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Page 5 of 204
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.