Range of non-verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in DZR brass bodies. Maximum working pressure 16.0 bar Maximum operating temperature 85°C
Range of aerators with plastic bodies and filter screens. Maximum operating temperature 60°C
Range of deck mounted side valve with brass bodies and chrome trim sets. Models PDV030, PDV032, PDV067, PDV068 incorporate quarter turn ceramic disc headworks and models PDV029, PDV031 incorporate half turn ceramic disc headworks with various operating members (See models). Models PDV 031, PVD 032 and PVD 068 are supplied with metal back nuts. Models PDV 029, PDV 030 and PDV 067 are supplied with plastic backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of thermostatic cartridges with plastic bodies and NBR ‘O’-rings. All models incorporate a stainless steel filter. For insertion into specifically dimensioned bores. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C. Maximum operating temperature 60°C for Model 0426AFOC1-001.
Range of thermostatic elements with copper bodies. Maximum operating temperature 90°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic disc headworks and single lever operating members. The cold inlet to the tap incorporates incorporates an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2). The inlet of hose to the pull-out spray incorporates an approved check valve cartridge which has not been fully tested to demonstrate it provides backflow protection. The outlet of pull-out spray incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes, see model) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Model TVW112001000 and TVW112002000 are supplied with pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The cold water inlet incorporates an approved check valve cartridge, verified by test (as suitable for backflow protection against Fluid Category 2) The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork and single lever operating member.The spout outlet incorporates a plastic aerator Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate plastic flow straighteners. Maximum working pressure 10 bar. Maximum operating temperature 65°C
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chromium or matt black finish), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, metal, single outlet (swivel) combination tap assemblies (chromium plated or brushed brass) incorporating a ceramic cartridge or ceramic discs headwork with either single lever or cross top. The spout outlets incorporate a plastic aerator. The cold inlet incorporates an optional check valve cartridge (excluding model HS605) which has been verified by test as suitable for backflow protection against Fluid Category 2. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chrome plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout incorporates a waterfall outlet. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a thermostatic cartridge headwork controlling temperature with a manual override and a quarter turn ceramic disc controlling flow with a manual override and available with a range of dome and lever operating members. The assemblies also incorporate a lockable self-cancelling diverter to shower outlet. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
‘Composed’ range of three hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes, see model), incorporating quarter turn ceramic disc headworks with either single lever or cross top operating members. The spout outlets incorporate a plastic aerator. The products are supplied with stainless steel braided EPDM lined flexible hose assemblies for installation between the side valves and ‘T’ connector, as well as between the ‘T’ connector and the spout. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of floor standing bath mixers (chromium plated brass) incorporating a ceramic cartridge diverter headwork with dome type or single lever (F3034/6.WR model only) operating members. The spout outlet incorporates a plastic flow straightener. The products are supplied with a shower hose and handset and a floor mounting kit. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of floor standing bath mixers (chromium plated brass) incorporating a ceramic cartridge diverter headwork with dome type or single lever (CPHSP30346 model only) operating members. The spout outlet incorporates a plastic flow straightener. The products are supplied with a shower hose and handset and a floor mounting kit. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Spout outlet with brass body, incorporating aerator, available in different finishes. Maximum operating temperature 65°C.
Range of expansion vessels with butyl membranes. Maximum working pressure 8.0, 10.0, 16.0 or 20.0 bar (please refer to model). Maximum operating temperature 70 or 100°C (please refer to model).
Range of expansion vessels with butyl membranes. Maximum working pressure 8.0, 10.0, 16.0 or 20.0 bar (please refer to model). Maximum operating temperature 70 or 100°C (please refer to model).
Page 22 of 113
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.