Single-hole, single outlet (swivel) combination tap assembly (chromium plated brass body), incorporating quarter turn ceramic disk headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) pull out spray combination tap assemblies (brass bodies – various finishes) incorporating a ceramic cartridge headwork with a single lever operating member. The outlet incorporates a plastic aerator and a push button spray. The connection between the outlet and the hose incorporates an approved single check valve cartridge, however, the whole product has not been fully tested to demonstrate that it provides adequate backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 60.0°C.
Single-hole, single outlet (swivel) combination tap assembly (chromium plated brass body), incorporating quarter turn ceramic disk headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
A range of single-hole single outlet swivel combination tap assemblies with brass bodies (chromium plated). Incorporating ceramic cartridge headworks with various operating members. The spout outlets on some models incorporate a plastic aerator. Maximum working pressure - 10 bar. Maximum operating temperature - 60°C.
Range of wall mounted two hole, single outlet (fixed) combination tap assemblies (chromium plated brass bodies), incorporating a ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic aerator Maximum working pressure 10.0 bar. Maximum operating temperature: 70°C.
Range of two hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal or plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet fixed combination tap assemblies (chromium plated brass bodies) incorporating a ceramic cartridge headwork with single lever operating members. Both inlets incorporate approved check valve cartridges. However, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlets incorporate a plastic flow straightener, and the products are supplied with metal backnuts. All models incorporate a straight connector servicing valve located on both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with dome operating members. The spout outlets incorporate plastic aerators or flow straighteners. The product is supplied with metal back nuts. Maximum working pressure – 10.0 Bar Maximum operating temperature - 70 °C
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates plastic aerators. Maximum working pressure: 5.0 Bar. Maximum operating temperature: 70 °C
Range of two hole, single outlet, fixed, wall mounted shower valves (chromium plated brass bodies), incorporating a ceramic cartridge headwork with single lever operating members. The products incorporate a plastic aerator on the outlet and the inlets incorporate a stainless-steel strainer and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. All models incorporate a straight connector servicing valve located on both inlets. Maximum working pressure 5 Bar Maximum operating temperature 60°C
Wall mounted, concealed, two-hole single outlet (fixed) combination tap assembly with a brass body (various finishes), incorporating a ceramic cartridge headwork with a single leaver operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
---|---|---|---|---|---|---|---|---|---|---|---|
193806 X XXX | Various | ¾” BSP | 10 bar | 65 °C | PPI | Body | No | 1/4 Turn ceramic disk | Metal Backnuts | Aerator |
X XXX Denotes the following: First X: Different handle and the second, third & fourth XXX for different finishes: Handles: A (Lever type) Chrome – No suffix, Brushed brass – BGP, PVD Gold – PVD, Brushed Nickel – BN1, Gun Metal – GMG, Matt Black – MBK, Matt White – MWH, Stainless Steel – SS1, Black Chrome – BCP, Titanium – TIB and Antique Bronze – AB1.
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes). Incorporating a ceramic cartridge headworks with single lever operating members and a self-cancelling diverter to shower outlet with Type HC device (verified by test - suitable for backflow protection against Fluid Category 3 The spout outlet incorporates an aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Two hole, single outlet (swivel) combination tap assembly (chrome plated brass) incorporating non rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. Supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic aerators. Maximum working pressure 8.0 Bar. Maximum operating temperature 60°C
Range of wall mounted spout outlets (brass bodies - various plated) incorporating a plastic aerator. Maximum operating temperature: 60 °C
Deck mounted spout outlet with chromium plated brass body incorporating a plastic aerator. Maximum operating temperature 60°C.
Wall mounted spout outlet, (chromium plated brass body) incorporating a plastic aerator. Maximum operating temperature 60°C.
Range of Grohe ‘Atrio’ wall mounted spout outlets (brass bodies - various finishes), the outlet incorporates a plastic aerator. Maximum operating temperature: 60°C
Expansion vessel with a stainless-steel body. Maximum working pressure 15.0 bar. Maximum operating temperature 100°C.
The products incorporate two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3), a pressure reducing valve adjustable between 1.0 bar and 3.0 bar (but pre-set at 2.5 bar for 523.815 model and 1.4 bar for the 523.816 model). The product incorporates a push type valve which allows water to flow when operated until the required pressure is achieved. There is a drain port below the push valve piston chamber. Compression connections are for use with copper pipe (manufactured to EN 1057). Maximum supply pressure 10.0 bar. Maximum operating temperature 80°C.
Range of filter heads with plastic bodies. Models with threaded connections incorporate a non-return valve (not suitable for backflow protection). Maximum working pressure 8.0 bar. Cold water use only.
Inline filter with plastic body. Maximum working pressure 5.0 bar. Cold water use only.
Range of RidgeLock™ sets consisting of Ridgeline corrugated stainless steel tubing adapter sealing rings connected using EN 1254-2 brass fittings to achieve a compression connection. Maximum working pressure 5 bar. Maximum operating temperature 85°C
Range of press fittings (brass bodies - various finishes) with stainless steel press (Unipress MLCP ) collars and EPDM O-rings for use with “EA” range of PEX/AL/PEX multilayer pipe (for press fitting connections and compression for EHA adaptor fittings only) or copper pipe manufactured to EN1057 (compression connections). Maximum operating temperature: 95°C. Maximum operating pressure: 10 bar.
Supreme range of fittings for use with PE pipes (manufactured to EN12201-2). Supplied with a plastic pipe support liner For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Range of stainless steel (SS316L) pressfit fittings with EPDM ‘O’-rings for use with stainless steel pipe (manufactured to EN10312). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of copper end feed fittings for use with copper tube to EN 1057. For above and below ground use. Maximum working pressure: 6mm-54mm 16.0bar, 64mm-108mm 10.0bar. Maximum operating temperature 85°C
WC dual flush valves with a plastic body and incorporates an internal overflow. Cold water use only.
Shower wastewater heat recovery units with a copper body and twin wall separation. Maximum working pressure 10.0 Bar. Maximum operating temperature 45°C.
Range of water meters with plastic bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of electromagnetic water meters with stainless steel bodies and natural rubber liners. Maximum working pressure 10.0 Bar Maximum operating temperature 50.0°C
Range of in-line single jet water meters with brass bodies. Products incorporate plastic strainers. Maximum working pressure: 16.0 Bar. Maximum operating temperature: 85.0°C.
Range of ultrasonic water meters with brass bodies. The products incorporate a motorised butterfly valve on the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line water meters with brass or plastic bodies. Models with a minimum length of 130mm and a maximum operating temperature of 50°C are supplied with an optional, non-return valve to be fitted by the installer (not suitable for backflow protection). Maximum working pressure 16.0 bar. The meters can be supplied with a maximum operating temperature of 50°C or 70°C.
Range of water meter manifolds incorporated into a meter chamber. The inlet of all models incorporates an isolation valve and an approved check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection. MK7000003003 is for use with MDPE plastic pipe (manufactured to BS EN 12202-1:2011). Maximum working pressure 12.5 bar. Cold water use only.
Water meter manifold with a gunmetal body. The product incorporates a non-return valve (not suitable for backflow protection) and a spherical valve on the inlet. Maximum working pressure 16.0 bar. Cold water use only.
Mixing valve incorporating a brass body and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure10.0 bar. Maximum operating temperature 65°C.
Range of click type, pop-up wastes with metal bodies. Maximum operating temperature 60.0°C
Range of horizontal multistage pumps with stainless steel bodies, diffuser and impellers and EPDM ‘O’-rings. The products incorporate a graphite-SiC-EPDM shaft seal. The products incorporate a drain plug. Maximum working pressure 8.5 bar. 9Maximum operating temperature 80°C.
Range of booster pumps with stainless steel bodies, impellers and non-return valves (not suitable for backflow protection) at the inlets. Maximum working pressure: 6.0 Bar. Cold water use only.
Range of multistage and single stage water pumps with stainless steel bodies and impellers. Maximum working pressure 4.0 bar. Maximum operating temperature 85°C
Range of multistage and single stage water pumps with stainless steel bodies and impellers. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C
Range of multistage and single stage water pumps with stainless steel bodies and impellers. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C
Concealed, ceiling mounted installation sets and shower outlets. The inlets incorporate a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower handsets (plastic bodies – various finishes), incorporating a plastic flow regulator on the inlet. Open outlet use only. Maximum operating temperature: 60 °C
Range of overhead shower outlets with brass bodies (various finishes). The inlet incorporates a plastic flow regulator and stainless steel strainer. Maximum operating temperature 60°C
Range of shower handsets incorporating chromium plated ABS plastic bodies. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60.0°C
Range of shower handsets with plastic bodies incorporating an integral filter. The inlet incorporates a combined washer and a strainer, plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C. Open outlet use only.
Range of (chrome plated) plastic shower handsets, each supplied with five (optional) plastic flow regulators (x2 blue, light green, dark green and grey). Maximum operating temperature 60°C.
Page 210 of 222
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.