Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass), incorporating a two quarter turn ceramic disk headworks and cross top operating members. The spout outlet incorporates a flow straightener. Supplied with single check valves (suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated or brushed nickel coated brass), incorporating two quarter turn ceramic disk headworks and lever operating members. The spout outlet incorporates a plastic aerator. Supplied with single check valves (suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork controlling the hot and cold flow. The 63264 model also incorporates a push to open, push to close, ‘detent’ headwork intended to control a filtered water supply. The spout outlets incorporate a plastic aerator. The cold water inlet hose is supplied with a chrome plated brass adaptor (½” BSP (F) x ½” BSP (M)) incorporating a check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2). The 63264 model is also supplied with brass tee piece (½” BSP (F) x ½” BSP (M) x spigot (for quick connector)) for connection prior to the brass adaptor containing the check valve cartridge. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (fixed) combination tap assemblies (various finishes) with electronically controlled functions to allow the tap to dispense boiling water, chilled water or sparkling water from under counter units (not supplied). The spout outlet of ‘Arc’ models incorporates a plastic flow straightener. All models incorporate a separate vent outlet within the tap spout for the near-boiling water circuit. Near-boiling circuit has a maximum operating temperature 100°C. Hot-water circuit has a maximum operating temperature of 65°C.
Range of two hole, single outlet (fixed) combination tap assemblies incorporating brass body (chromium plated) and ceramic disc headwork with dome type operating members The temperature is controlled independently via a thermostatic cartridge with dome type operating member and manual override button. The spout outlet incorporates a plastic flow straightener. Both inlets incorporate a stainless steel strainers and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 45°C.
Two hole, single outlet (fixed), combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a quarter turn ceramic cartridge headwork with single lever operating member. Both inlets incorporate eccentric isolation valves and plastic flow regulators. The spout outlets incorporate plastic flow straighteners. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating two quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating a single sequential headwork which controls flow and temperature with a single lever operating member. Both inlets incorporate eccentric isolation valves, flow restrictors and single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator and the product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted two hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating a single sequential headwork which controls flow and temperature with a single lever operating member. Both inlets incorporate eccentric isolation valves, flow restrictors and single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator and the product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Deck mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet, (swivel) combination tap assemblies (chrome plated brass) incorporating a ceramic cartridge headwork with single lever type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating rising spindle headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Two hole, double outlet swivel combination tap assembly (chrome plated brass), incorporating two quarter turn ceramic disc headworks with lever operating members. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, double outlet swivel combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disc headworks with lever operating members. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, two hole, double outlet swivel combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disc headworks with lever operating members.. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (brass body with various finishes) incorporating quarter turn ceramic disc headworks with cross top type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
A range of combined bath filler and overflow with a plastic body with a variety of different trims. The products are supplied with a cable operated pop-up waste. For open outlet use only. Maximum operating temperature 65°C.
Bath spout with brass body (chromium plated). The outlet incorporates a plastic aerator. Maximum operating temperature 60°C.
Uponor S-Press (black and grey) composite fittings, Uponor S-Press composite PPSU reducers with S-Press PLUS composite PPSU nipples, Uponor RS fittings & Uponor S Press Metal Press fittings for use with for use with Uponor MLC pipe. Maximum working pressure and operating temperature: 10.0 bar@70°C Maximum working pressure and operating temperature: 16.0 bar @ Cold water use only.
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of polypropylene push-fit fittings and inserts for use with MDPE pipe (manufactured to BS EN 12201). For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Range of polypropylene push-fit fittings with inserts for use with MDPE Pipe (manufactured to BS EN 12201-2) on one side of the fitting and PB (BS 7291), PEX (BS 7291) or Copper (BS EN 1057) on the other. Models UTS147-DB, UTS197-DB & UTS251-DB are for above and below ground use. All other models are for above ground use only. Maximum working pressure when using 20mm pipe is 16.0 bar. Maximum working pressure when using 25mm & 32mm pipe is 12.5 bar. Cold water use only.
WC dual flush outlet valve with plastic body silicone rubber seal. The valve is operated via a lift assembly with an either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of stainless-steel heat exchangers. Maximum working pressure of primary Circuit 3.0 bar. Maximum working pressure of secondary Circuit 10.0 bar. Maximum operating temperature 80˚C
Gas fired water heaters incorporating a heat exchanger and flow sensor. The inlet incorporates a plastic strainer. The products are supplied with isolation valves for installation on the cold inlet and hot outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60˚C
LCB700 range of internal and external oil-fired condensing combination boilers providing domestic hot water and pressurised central heating via a plate heat exchanger. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The primary (space heating) circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). Operating parameters: Primary (space heating) circuit: Maximum working pressure 2.5 Bar. Maximum operating temperature 105°C. Secondary (DHW) circuit: Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of ice making machines which incorporate a solenoid valve to control the flow. Maximum working pressure 5.0 bar. Cold water use only.
Range of commercial ice making machines which incorporate a solenoid valve controlling the flow. Maximum working pressure 7.8 bar. Cold water use only.
Range of water meters with plastic or brass bodies. The inlets incorporate a plastic strainer. Maximum working pressure 16.0 bar. RTKD range has a maximum operating temperature of 50°C. RTKD-L range has a maximum operating temperature of 30°C.
Ultrasonic water meter with a blue epoxy coated ductile iron body and EPDM ‘O’ rings. Maximum working pressure 16.0 Bar. Maximum operating temperature 50°C.
Range of rotating piston, volumetric in-line water meters with brass bodies. Maximum working pressure 16.0 bar. Cold water use only.
Water meter incorporating a brass inner body, a plastic outer body and liquid silicone ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meter manifolds with plastic bodies. The inlets incorporate a spherical valve and a non-return valve (not suitable for back flow protection). Model MD1010101BM is for use with Irish Heavy gauge pipe manufactured to 15134/1977. All other models are for use with blue MDPE pipe manufactured to EN12201. Maximum working pressure 12.5 bar. Cold water use only.
Range of water meter manifolds with a plastic body and a spherical valve at the inlet. Models MB2012525DM & MB2010303DM incorporates two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection Model MB201010BM is for use with Irish Heavy gauge pipe manufactured to 15134/1977. All other models are for use with blue MDPE pipe manufactured to EN12201. Maximum working pressure 12.5 bar. Cold water use only.
`Groundbreaker Mk3` water meter box incorporating a concentric water meter manifold (plastic body) with screw down stop valve, single check valve (verified by test as suitable for backflow prevention up to fluid category 2) & compression fittings. The product is intended to be installed upon the external wall of a premises and incorporates internal insulation (insulation not verified by test). For use with MDPE pipe (manufactured to EN12201). Maximum working pressure 12.0 bar. Cold water use only.
Range of threaded fittings with either plain brass, nickel plated brass or chrome plated brass bodies. Maximum operating pressure 16.0 bar. Maximum operating temperature 99°C.
Range of circulation valves and flow sensor valves with EPDM seals and O-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 90ºC.
Range of pressure transmitters with stainless steel bodies. Maximum working pressures: DST-P140 model 25.0 bar, all other models 50.0 bar. Maximum operating temperature 90°C.
Range of pumps with either brass or stainless-steel bodies, stainless steel impellor and NBR ‘O’ rings. 20 & 33 brass series have a maximum working pressure of 16.0 bar. 33 stainless-steel series has a maximum working pressure of 20.0 bar. 22, 24 ,26, 38, 31, 32 & 34 series have a maximum working pressure of 20.0 bar. Cold water use only.
Range of shower outlets incorporating brass bodies (various finishes). Maximum operating temperature 60°C.
Range of wall or ceiling mounted shower arms with brass bodies (various finishes). Maximum operating temperature 65°C.
Shower outlets, with NBR and EPDM ‘O’-rings and silicone nozzles. The shower handset has a plastic body with a chrome plated brass outer body and the overhead shower outlet and shower arm have chrome plated brass bodies The inlet of the shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the overhead shower consists of socket and ball joint. The inlets of both products incorporates a combined NBR gasket and stainless steel strainer. Maximum operating temperature 60°C.
Range of overhead shower heads and arms incorporating brass or ABS body. The inlet of models KSAB4K and HEAH06BK incorporates a stainless-steel strainer and plastic flow regulator. Maximum operating temperature 60°C.
Range of wall or ceiling mounted overhead shower outlets (chromium plated brass) and shower arm. Maximum operating temperature 60°C.
Range of wall mounted handshower, hose and elbow sets with metal bodies (various finishes), incorporating an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Handsets incorporate an approved check valve cartridge , however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Range of inline strainers incorporating DZR brass bodies and a stainless steel mesh. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Drain cock elbow incorporating a DZR brass body with EPDM ’O’-rings (ZELB250445 model) or NBR ‘O’-rings (ZELB250446 model added July 2022). Both models are for use with copper pipe (manufactured to BS EN 1057). Maximum working pressures: ZELB250445 model - 10.0 Bar. ZELB250446 - 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps with brass bodies (chromium plated) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Page 3 of 71
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.