Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of polypropylene push-fit fittings and inserts for use with MDPE pipe (manufactured to BS EN 12201). For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Range of polypropylene push-fit fittings with inserts for use with MDPE Pipe (manufactured to BS EN 12201-2) on one side of the fitting and PB (BS 7291), PEX (BS 7291) or Copper (BS EN 1057) on the other. Models UTS147-DB, UTS197-DB & UTS251-DB are for above and below ground use. All other models are for above ground use only. Maximum working pressure when using 20mm pipe is 16.0 bar. Maximum working pressure when using 25mm & 32mm pipe is 12.5 bar. Cold water use only.
Range of SUS316L & SUS304 stainless steel press fittings for use with stainless steel pipe manufactured to EN 10312. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass and copper fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 18.6 bar. Maximum operating temperature 100°C.
Range of WC dual flush drop valves comprising of a plastic body, silicone seal and an internal overflow. The valve is operated via a push button or lever assembly for either full or reduced flush. Cold water use only.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.
Shower waste water heat recovery unit, consisting of a PVC-U waste pipe with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10.0 bar. Maximum operating temperature 30°C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.
RINNAI range of wall mounted combination boilers.The unit incorporates a stainless-steel plate heat exchanger pressure relief valve set at 3.0 bar and an expansion vessel on the primary circuit. Maximum working pressure of primary circuit is 2.5 bar and secondary circuit is 10.0 bar. Maximum operating temperature 60˚C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, incorporating a pressure relief valve set at 3.0 bar and expansion vessel on the primary circuit. The inlet of the replenishing valve between the primary and secondary circuits incorporate a plastic strainer. Maximum working pressure 2.5 bar (primary) and 6.0 bar (secondary). Maximum operating temperature 85˚C.
Water meter incorporating a brass inner body, a plastic outer body and liquid silicone ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meter manifolds with plastic bodies. The inlets incorporate a spherical valve and a non-return valve (not suitable for back flow protection). Model MD1010101BM is for use with Irish Heavy gauge pipe manufactured to 15134/1977. All other models are for use with blue MDPE pipe manufactured to EN12201. Maximum working pressure 12.5 bar. Cold water use only.
Range of water meter manifolds with a plastic body and a spherical valve at the inlet. Models MB2012525DM & MB2010303DM incorporates two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection Model MB201010BM is for use with Irish Heavy gauge pipe manufactured to 15134/1977. All other models are for use with blue MDPE pipe manufactured to EN12201. Maximum working pressure 12.5 bar. Cold water use only.
Plastic bodied flow sensor. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘E-WATER BLOCK’ self-closing valves with black plastic bodies and stainless-steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of booster pumps with stainless steel bodies and impellers (AISI 304: AL-RED models or AISI 316: CP models), EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure: CP(m) 100-130-132-150-158 and AL-RED(m) 600-610-620 models: 6.0 bar. All other models: 8.0 bar. Maximum operating temperature 90°C.
Range of overhead shower outlets with brass bodies (various finishes), with a ball joint, EPDM ‘O’-rings and a NBR seal. The inlet incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower handsets and shower heads chrome plated plastic bodies and built in combined flow restrictors/approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models added March 2023 are available in various finishes, see model.
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall or ceiling mounted overhead shower outlets (chromium plated brass) and shower arm. Maximum operating temperature 60°C.
Page 3 of 45
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.