Range of two hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes), incorporating quarter turn headworks with various type operating members and a manual diverter to shower outlet. The spout outlets incorporate either a plastic flow straightener or plastic aerator. Model (173605) has an open outlet type spout. The products are supplied with metal backnuts, shower hose and handset. Maximum working pressure 10 bar. Maximum operating temperature 65°C but 70°C for models 173605, 173605 MBK1 and M33145E
Range of two hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes), incorporating quarter turn headworks with various type operating members and a manual diverter to shower outlet. The spout outlets incorporate either a plastic flow straightener or plastic aerator. Model (173605) has an open outlet type spout. The products are supplied with metal backnuts, shower hose and handset. Maximum working pressure 10 bar. Maximum operating temperature 65°C but 70°C for models 173605, 173605 MBK1 and M33145E
Two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with a shower hose and handset and have metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of two-hole, single outlet, fixed, combination tap assemblies, (chrome plated brass bodies), incorporating quarter turn cermic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with a shower hose and shower handset. Maximum working pressure 6 bar. Maximum operating temperature 60°C
Wall mounted, two-hole, single outlet, (fixed), combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a joy stick type operating member. The product incorporates a self-cancelling diverter to a shower outlet. The spout outlet incorporates a plastic flow straightener. The shower outlet incorporates an approved check valve cartridges, however, the complete assembly has not been fully tested to demonstrate that it provides backflow protection. Maximum working pressure 10 bar. Maximum operating temperature 60°C
Range of two-hole, single outlet, fixed, combination tap assemblies, (chrome plated brass bodies), incorporating quarter turn cermic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with a shower hose and shower handset. Maximum working pressure 6 bar. Maximum operating temperature 60°C
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies with (brass bodies - various finishes), incorporating two detent headworks. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating manual override button. The spout outlet incorporates a plastic aerator. The inlets incorporate approved single check valve cartridges with strainers, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole, double outlet, fixed combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. The products are supplied with metal back nuts. Maximum operating pressure 6 bar. Maximum operating temperature 85°C
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies incorporating quarter turn ceramic disc headwork with cross top or single lever operating members (See models). The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of three hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with lever type operating members. The spout outlet incorporates a plastic aerator. This products are supplied with a click-type pop up waste. Maximum operating pressure 10 bar. Maximum operating temperature 60°C
Three hole, single outlet (fixed) combination tap assemblies (brass body – various finishes). Incorporating quarter turn ceramic disc headworks with cross top operating members. The spout outlet incorporates a plastic aerator. The product is supplied with stainless steel braided PEX lined flexible connection hoses, a lever operated pop-up waste and metal backnuts. Maximum working pressure 5 bar. Maximum operating temperature 65°C
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks and dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet (swivel) combination tap assemblies, incorporating quarter turn ceramic disc headworks with single lever or cross top type operating members (see models). The spout outlets incorporate plastic aerators. The products are supplied with stainless steel braided PEX lined flexible hose assemblies for installation between the side valves and the spouts, as well as click type pop-up wastes (verified by test) and metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of three hole, single outlet, combination tap assemblies (brass bodies – various finishes trim sets). Incorporating a ceramic cartridge headwork controlling the flow to the shower handset and a second ceramic cartridge headwork controlling flow to an external outlet (not supplied), both with single lever operating members. The product is supplied with a shower hose and handset, the handset incorporates a single check valve on the inlet, however, the complete product has not been fully tested to demonstrate backflow protection. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted spout outlets (chrome plated brass bodies), incorporating plastic aerators. Maximum operating temperature 60°C
Range of filling loop assemblies, consisting of either a stainless steel braided, EPDM lined flexible hose assembly (300616 VIS and 300614 VIS) or a rigid copper tube assembly (3006315 VIS), a lever operated spherical valve and an in-line, non-verifiable double check valve assembly verified by test (suitable for backflow protection against fluid category 3) which incorporates an integral lever operated spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C , and 85°C for 300615 VIS.
Carbon block filter cartridge with plastic body. Maximum working pressure 8.2 bar. Cold water use. In April 2024 a filter head was added to the approval.
‘Uponor S-Press Plus’ compatible pipe and fittings system consisting of Uponor MLC pipe and Uponor Uni Pipe for use with Uponor S-Press plus metal and PPSU fittings. Maximum working pressure and operating temperature: 10.0 bar@70°C. Maximum working pressure and operating temperature: 16.0 bar @ Cold water use only.
Range of stainless steel press-fit fittings and pipes, the fitttings incorporating stainless steel bodies and EPDM O-ring. Joints are made using a pressing tool for M profile. All the models are for both above ground and below ground use. YHPFM304 models are made of SS304 stainless steel, used with Yuhe SS304 pipes manufactured to EN10312. YHPFM316L models are are made of SS316L stainless steel, used with Yuhe SS316L pipes manufactured to EN10312. Maximum working pressure 16 bar. Maximum operating temperature 85°C.
Range of stainless steel press-fit fittings (316L) and pipes (316L - EN 10312), the fitttings incorporate EPDM O-rings. Crimp joint is achieved by a M profile crimp jaws. Maximum operating pressure 16 bar. Maximum operating temperature 85°C
Range of stainless steel press-fit fittings (316L or 304) and pipes (SUS316L or SUS304 - EN 10312), the fitttings incorporate EPDM O-rings. Crimp joint is achieved by a M profile crimp jaws. Maximum operating pressure 16 bar. Maximum operating temperature 85°C
Geberit range of ‘FlowFit’ press Fittings for use with ‘Geberit FlowFit Pipe ML’ and ‘Geberit FlowFit Pipe coils ML’ (insulated and uninsulated) PERT/Al/PERT pipes. The fittings are made from PPSU or lead free silicon bronze. Operating parameters: 16.0 bar@cold water and 10.0 bar@70°C.
‘Tweetop system’ consisting of brass bodied nickel plated, compression or press fit (‘U’ crimping profile) fittings for use with ‘Tweetop multilayer pipe’ PERT/AL/PERT. Maximum working pressure 10.0 Bar. Maximum working temperature 95°C.
Instantor range of brass compression fittings for use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
‘AquaGas M range’ of copper and brass press fit fittings with NBR ‘O’-rings for use with copper tube (manufactured to BS EN 1057). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of pipe repair clamps incorporating EPDM double seals. The products are intended for use with stainless steel pipe manufactured to EN1124. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
WC dual flush drop valve with plastic body silicone and rubber seal. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold Water Use Only.
Range of packaged plate heat exchangers comprising of stainless steel plates with EPDM gaskets. The products are supplied with twin primary circulation pumps, a secondary circulation pump, 3 port control valve and a control panel with full Mod BUS BMS connectivity. Maximum working pressure - Primary and Secondary circuits 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel, pressure relief valve set at 3.0 bar and flow regulators. The inlets to both domestic hot water and primary circuits are controlled via screwdriver operated angled spherical valve. The primary circuit can be filled via a built in CAB device, that has been verified by test (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 80°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of integrated water circuits with plastic bodies and EPDM ‘O’ rings and gaskets. The assemblies incorporate flow switches, plate heat exchangers and plastic flow regulators. The primary circuit incorporates a 3.0 bar rated pressure relief valve. Maximum working pressures: 2.5 bar primary circuit, 10.0 bar secondary circuit. Maximum operating temperature 85°C.
“CZ 3000” range of water meters with brass bodies and plastic turbines. The inlets incorporate plastic filters. The outlets are fitted with approved check-valve cartridges (however, the complete product has not been fully tested for and is not intended to provide backflow protection). Maximum working pressure 16.0 bar. Maximum operating temperature 30°C.
Range of water meter manifolds with plastic bodies which incorporates a (spherical) stop valve. The MB40408256BM, MB40408254NM, MB40408326BM, MB40408324BM, MB40425256BM MB40425254BM, MB40432326BM and MB40432324BM models incorporate a non-return valve. The MB40408255DCVBM and MB40408254DCVBM models incorporate two non-return valves. The product is supplied with pipe liners for use with the pushfit connections. The pushfit connections are for use with PE80 pipes (manufactured to BS EN 12201). Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds with plastic (MBB1100 prefix models) or gunmetal (MBB2010 prefix models) manifolds. The inlet to the manifold incorporates a quarter turn spherical valve. The products also incorporate a non-return valve. Maximum working pressure 12.5 bar. Cold water use only
‘Tanktronic‘ range of water level monitoring kits comprising of a main control unit, vent box and single or double stainless steel sensors. Open outlet use only. Maximum operating temperature 23°C
Range of concealed, wall mounted rough sets with DZR brass bodies. Maximum working pressure 10.0 Bar. Maximum operating temperature 75.0°C.
‘SCALA1 TWIN’ range of booster pump sets, comprising of two pumps with plastic bodies, plastic impellers, EPDM and NBR ‘O’-rings and an accessory set consisting of a base plate, plastic manifold and four brass spherical valves. Each pump incorporates a non-return valve. Maximum working pressure 8.0 bar. Cold water use only.
Range of shower handsets, (plastic bodies - various finishes). Maximum operating temperature 70 °C.
Range of plastic shower handsets available in various finishes. Maximum operating temperature 65°C.
Range of colour coded disposable shower kits incorporating a white PVC shower hose with EPDM washer and shower handset incorporating a plastic body (white), NBR ‘O’-rings, and a coloured locking ring around the shower face. Maximum working pressure: 5.0 bar Maximum working temperature: 60°
Range of ‘Y’- pattern strainers with cast iron bodies (blue epoxy coated) and brass plugs (EN12164), incorporating stainless steel filters (EN10088) and EPDM ‘O’-rings. Maximum operating pressure 16 bar. Maximum operating temperature 100°C
Range of ‘Y’-pattern strainers with a brass or DZR brass body, stainless-steel strainer and PTFE gasket. Maximum operating pressure 20.0 bar. BS6920 85°C.
In-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85.0°C
Drain valve with a DZR brass body and rising spindle headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pillar taps, (chrome plated brass bodies), incorporating quarter turn cermic disc headworks and single lever operating members. The products include metal back nuts. Maximum operating pressure 10 bar. Maximum operating temperature 60°C
Range of PEX or PVC lined shower hoses with a chrome plated interlocked stainless steel outer and EPDM washers. Maximum operating temperature 60°C.
Range of PVC or EPDM lined shower hoses with stainless steel outer (chrome or black finish) or PVC reinforced (chrome plated finish) outer layer. Maximum operating temperature 65°C.
Hydravend range of PVC coated (grey or white in colour), hytrel lined, flexible thermoplastic hoses, incorporating a white quadruple layered hose with a black TPE inner lining. The hoses are supplied with plastic or brass end connectors and with or without servicing valves. Maximum working pressure and temperature: 12.0 bar Cold water use only.
Range of shower hoses with a rubber outer layer (various finishes, see models) and either PVC or PEX inner liner (see models), EPDM or NBR O-rings (see models) and either brass or stainless-steel connectors (see models). Open Outlet use only. Maximum operating temperature 85.0°C
Wall mounted, manually operated shower mixer valve (chromium plated brass body), incorporating a ceramic cartridge with a joystick type operating member. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10 bar. Maximum operating temperature 60°C
Page 147 of 225
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.