Overhead shower outlets with chrome plated brass bodies, incorporating EPDM O rings. Maximum operating temperature 65.0°C
Range of shower handsets with chrome plated plastic bodies and EPDM O-rings. The inlets incorporate a plastic strainer. Maximum operating temperature 60°C.
Range of disposable shower kits, consisting of shower handset and shower hose with EPDM ‘O’-rings. Maximum operating temperature 65.0°C.
Range of multi-function shower handsets with white or chrome plated plastic bodies. The inlet incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Wall mounted shower outlet with chrome plated body. The inlet incorporates a flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum operating temperature 60°C
Range of shower outlets and shower arms (brass bodies - various finishes - see model). The wall mounted and ceiling mounted shower heads incorporate integral plastic flow regulators and also include stainless steel strainers on the inlets. The shower handset has a plastic flow regulator and a stainless steel strainer on the inlet. Maximum operating temperature 60°C.
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Stainless steel bodied flow switch, with integral plastic plunger. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of hose union, spherical valve type bib taps with (nickel plated) brass bodies and chrome plated brass ball. The outlet incporates a plastic flow straightener Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of basin pillar taps (chrome plated brass bodies) with quarter turn ceramic disc headworks with cross-top operating members. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Pillar tap incorporating (chromium plated) brass body quarter turn ceramic disc headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C. The product is supplied with metal backnuts.
Range of wholesome-water nickel plated brass manifolds for use with ‘Emmeti Gerpex RA’ Pexb/Al/Pexb Multilayer pipe and ‘Emmeti Alpert’ PERT/AL/PERT Multilayer Pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. Range of closed circuit use nickel plated brass manifolds for use with ‘JG Speedfit Layflat Polybutylene Barrier Pipe (models 10BPB & 15BPB)’. Maximum working pressure 3.0 bar. Maximum operating temperature 92°C.
Wall mounted, exposed, manual blending valve (chromium plated brass), incorporating a ceramic cartridge headwork controlling both the flow and temperature with a single lever operating member. The shower outlet incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Not supplied with hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of concealed manually operated blending valves (brass bodies with chromium plated exposed trim sets) incorporating self-cancelling diverters (except models added December 2023 – 36020626 & 36020832) ceramic cartridge headworks controlling both temperature and flow with a single lever operating member. The inlets and the outlet incorporate approved check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Range of wall mounted thermostatic shower valves (chrome plated brass bodies) incorporating a two-way diverter valve controlling the flow between shower outlets with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member with manual override button. Both inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted thermostatic shower valves (chrome plated brass bodies) incorporating a two-way diverter valve controlling the flow between shower outlets with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member with manual override button. Both inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of concealed thermostatic valves with thermostatic cartridges. Some models include diver between outlets. (See model codes) All models incorporate cube, dome, cross-top or single lever type operating members. The inlets incorporate stainless steel strainers and single check valve cartridges; however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted, thermostatic shower valve (chromium plated brass), incorporating a quarter turn ceramic disc headwork controlling the flow with a cross top operating member. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member. The product is supplied with a shower riser, overhead shower rose, shower hose and handset. The product incorporates a self-cancelling diverter on the shower riser. Each inlet incorporates a stainless-steel strainer, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of T type thermostatic blending valves with DZR brass bodies and EPDM O-rings. The inlets incorporate stainless steel strainers and single check valve cartridges verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Page 113 of 394
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.