Range of filling loop assemblies, consisting of either a stainless steel braided, EPDM lined flexible hose assembly (300616 VIS and 300614 VIS) or a rigid copper tube assembly (3006315 VIS), a lever operated spherical valve and an in-line, non-verifiable double check valve assembly verified by test (suitable for backflow protection against fluid category 3) which incorporates an integral lever operated spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C , and 85°C for 300615 VIS.
A range of blue epoxy coated steel reverse rinsing fine filters with a stainless-steel sieve and an EDPM O-ring. Supplied with two pressure gauges and metal ball valve on the drain. Maximum working pressure 16 bar. Maximum operating temperature 40°C.
‘Numepress’ range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.
Range of electric instantaneous water heaters. The DEX and DCX models incorporate a spherical ball valve on the inlet. The CEX and DEX models incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet incorporates a strainer. Maximum working pressure 10 bar (DEX models only) All other models open outlet. Maximum operating temperature: ES3/4/5 and Zip Hydrotap G4/G5 ranges – 65ºC. CEX, DEX and DCX ranges - 70°C.
Range of vertical vented cased copper cylinders with indirect coils. The secondary circuit incorporates a thermostatic mixing valve. The inlet consists of a ball valve with strainer, inline non verifiable single check valve and mini shock arrestor. Cylinder are supplied with a factory fitted immersion heater. Maximum working pressure - secondary 6.0 bar, primary 2.2 bar. Maximum operating temperature - secondary is 60°C, primary 85°C
Range of water meter manifolds incorporating DZR brass bodies, PTFE washers, a non-return valve and ball valve. Maximum working pressure 10.0 bar. Cold water use only.
Range of water meter manifolds with gun metal bodies and ball valve with either a quarter turn stop valve or screw down stop valve. The products incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds with plastic bodies, incorporating plastic pushfit inlets and plastic pushfit outlets. The inlets incorporate a spherical ball valve. Models MB40408256DCVDM & MB40408254DCVDM incorporate two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16 bar. Cold water use only.
Range of water meter manifolds with plastic bodies, incorporating plastic inlets and gunmetal outlets. The inlets incorporate a spherical ball valve. Models MB40408036CGDCVM & MB40408034CGDCVM incorporate two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16 bar. Cold water use only.
Hygienic flush box providing a timed flush facility. The supply is via a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection, flow sensor, spherical ball valve and strainer. The products incorporate a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The units have multiple interface user functions for timed flush, wireless technology and data storage. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of combined storage and booster sets, incorporating a cold-water storage cistern, submersible pump, solenoid valve or alternative actuated ball valve, non-return valve (not suitable for backflow protection), isolation valves and expansion vessel. Maximum working pressure 10.0 bar. Cold water use only.
Spherical valve with a brass body and ball, PTFE seat, EPDM ‘O’-rings, a lever operating member and a drain connection outlet. Compression end connection for use with copper pipe (manufactured to BS EN 1057). The product is supplied with a brass cap and an EPDM washer which is interchangeable with the hose union spigot outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Wall mounted thermostatic shower valve (chrome plated brass), incorporating a ceramic disc diverter cartridge controlling the flow from shower to shower with a cube operating member. The temperature is controlled independently via a thermostatic cartridge, with a cube operating member, that also incorporates a manual override button. The product is supplied with a chrome plated shower handset, shower hose and riser rail assembly. The inlets incorporate approved check valve cartridges, (however, the complete product has not been fully tested to demonstrate that it provides backflow protection), chrome plated spherical ball valves and stainless-steel strainers with EPDM gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted blending thermostatic shower valve (chrome plated brass), incorporating a quarter turn ceramic disc headwork controlling the flow. The temperature is controlled independently via a thermostatic cartridge. Both using cube type operating members. The inlets incorporate approved check valve cartridges; however, the complete assembly has not been tested to demonstrate it provides backflow protection. The inlets also incorporate ¾” BSP (M) x 15mm compression (chrome plated) spherical ball valves and EPDM washers incorporating stainless steel mesh strainers. The product is supplied with a chrome plated shower handset, shower hose and riser rail assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic shower valve (chrome plated brass), incorporating a ceramic disc diverter cartridge controlling the flow from shower to shower with a cube operating member. The temperature is controlled independently via a thermostatic cartridge, with a cube operating member, that also incorporates a manual override button. The product is supplied with a chrome plated shower handset, shower hose and riser rail assembly. The inlets incorporate approved check valve cartridges, (however, the complete product has not been fully tested to demonstrate that it provides backflow protection), chrome plated spherical ball valves and stainless-steel strainers with EPDM gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted blending thermostatic shower valve (chrome plated brass), incorporating a quarter turn ceramic disc headwork controlling the flow. The temperature is controlled independently via a thermostatic cartridge. Both using cube type operating members. The inlets incorporate approved check valve cartridges; however, the complete assembly has not been tested to demonstrate it provides backflow protection. The inlets also incorporate ¾” BSP (M) x 15mm compression (chrome plated) spherical ball valves and EPDM washers incorporating stainless steel mesh strainers. The product is supplied with a chrome plated shower handset, shower hose and riser rail assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of high and low pressure diaphragm float operated valves with brass body and backnuts. Maximum working pressure 8.0 or 10.0 bar (please refer to model). Cold water use only.
Range of high and low pressure diaphragm float operated valves with brass body and backnuts. Maximum working pressure 8.0 or 10.0 bar (please refer to model). Cold water use only.
Range of high and low pressure diaphragm float operated valves with brass body and backnuts. Maximum working pressure 8.0 or 10.0 bar (please refer to model). Cold water use only.
Page 1 of 6
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.