Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members or non-rising spindle headworks and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of three hole, single outlet (fixed) wall mounted, concealed tap assemblies with brass bodies and chrome plated trim set. Consisting of a rough in set 45089 and extermnal trim 65090 and 65091. Incorproating a quarter turn ceramic disc headworks and single lever operating members.The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies incorporating chrome plated brass bodies, quarter turn ceramic disc headwork with lever type operating members. The spout outlets incorporate a plastic aerator. The product is supplied with stainless steel braided PEX lined flexible hose assemblies to connect between the valves and spout Model 23484W-4-CP is supplied with pop up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated) incorporating quarter ceramic disc headworks and various operating members (see model). The spout outlet incorporates a plastic aerator. The product is supplied a click type waste and stainless steel braided EPDM lined flexible hose assemblies for connecting the side body headworks and the spout junction. Maximum working pressure 5.5 bar. Maximum working temperature 60 °C.
Range of four-hole, single outlet (fixed) combination tap assemblies, (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with various operating members and a self-cancelling diverter to shower outlet. The spout outlets incorporate plastic aerators. The products are supplied with a shower hose and metal back nuts. The hose connector incorporates an approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Expansion vessels incorporating a stainless steel body and EPDM membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 100˚C.
Range of expansion vessels with EPDM membrane and stainless steel flange connections. Maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass tee fittings for use with copper pipe to EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘HE-705X & HE-715X’ ranges of brass crimp fit fittings incorporating EPDM ‘O’-rings for use with copper pipe (manufactured to EN1057-2006). HE-7052/7053/7058/7059 & HE-7152/7153/7158/7159 models also incorporate a NBR gasket. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
VSH XPRESS Range of copper press fittings with EPDM rubber ‘O’-rings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Low profile mechanical seal intended for the internal repair of pipe joints. The system incorporates two stainless steel compression rings and an EPDM seal. For above and below ground use. Maximum working pressure 22.5 bar. Cold water use only.
OMEG range of wall mounted, near-boiling water dispensers (cased and insulated). The products incorporate a solenoid valve which controls the flow, a stainless-steel tank, 3 or 5L (see model), and a plastic strainer at the inlet. Maximum supply pressure 10.0 bar. Cold water supply only. Maximum operating temperature 95˚C
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of gas fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The cold inlet incorporates an angled spherical valve with a brass body, chromium plated brass ball and a lever operating member. The primary circuit incorporates an expansion vessel, isolation valves on flow and return, drain valve and a pressure relief valve set at 3.0 bar. Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature for the secondary circuit is 55˚C. Cold supply only.
Greenstar Heatslave II range of floor standing oil-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, which incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The cold water inlet incorporates a screwdriver operated spherical valve followed by a plastic flow regulator inserted within the pipework. Maximum working pressure: Primary circuit 2.5 bar. Secondary circuit 10.0 bar. Maximum operating temperature 82°C.
Range of air cooled ice making machines . Inlet is controlled via solenoid valve. Maximum working pressure 5.5 bar. Cold water use only.
Page 86 of 177
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.