Wall mounted waterfall, bath spout (chromium plated brass), incorporating a flow regulator on the inlet and stainless-steel strainer at the spout outlet. Maximum operating temperature 80°C. Open outlet use only
Range of wall mounted spout outlets, (brass bodies with various finishes) incorporating a plastic aerator. Maximum operating temperature: 60°C
Range of wall mounted spout outlets incorporating brass bodies (various finishes) and plastic flow straighteners. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
Range of stainless-steel axial expansion bellows with threaded end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Chlorine dioxide dosing system consisting of PVC-U pipework and fittings. Maximum operating pressure 7.0 bar. Cold water use only.
‘CD3 Series’ chlorine dioxide dosing system incorporating a single check valve positioned at the point of injection. Maximum working pressure 6.0 bar. Cold water use only.
Range of expansion vessels with EPDM membrane and stainless steel flange connections. Models VB8, VB12, VB18 & VB24 have a maximum working pressure of 16.0 bar. All other models have a maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
Range of expansion vessels with stainless steel and epoxy coated carbon steel bodies incorporating a butyl rubber membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of filling loop assemblies consisting of an in-line isolation valve, in-line double check valve assembly which also incorporates an isolation valve (suitable for back flow protection against fluid category 3) and stainless steel braided EPDM lined hose. The isolation valves are operated via a single lever. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘Profine’ plastic bodied filter head incorporating EPDM ‘O’-rings for use with filter cartridges (not supplied).For use with LLDPE tube (manufactured to DIN 8072). All models can be specified with or without an integral bracket. Maximum working pressure 6.0 bar. Cold water use only.
Range of carbon block water filters and housings. Maximum working pressure 10.5 bar. Cold water use only.
Range of water filter housings with plastic heads and bodies (various colours - see model), incorporating NBR ‘O’-rings (158087/088/207/208/218/219/261 models only) or with EPDM ‘O’-rings (all other models). Big Blue for Cartridges - Maximum working pressure 6.9 bar (10” filter housings) and 6.2 bar (20” filter housings). Maximum working temp 38°C. All other models - Maximum working pressure 8.62 bar. Maximum working temp 52°C.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of M type press fittings with TP2 copper bodies and EPDM ‘O’-rings, for use with TP2 copper pipe to EN1057. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Dual flush WC outlet valve with an ABS body, incorporating a silicone seal & internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
Copper brazed micro plate heat exchanger with copper and stainless-steel (316/1.4401) plates. Maximum working pressure 25.0 Bar. Maximum operating temperature 100°C
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. The primary circuit has a maximum working pressure of 2.5 bar. The secondary circuit has maximum working pressure of 10.0 bar. Maximum supply temperature is 60°C. Maximum operating temperature of secondary circuit is 85°C.
Range of ice making machines. The inlet supply is controlled by a solenoid valve. Inlet hose supplied. Maximum working pressure 5.0 bar. Cold water use only.
Range of commercial air or liquid cooled ice making machines with flow controlled via solenoid valve. Maximum working pressure 7.8 Bar. Cold water use only.
‘Aquila V4 C1’ range of water meters (brass or bronze bodies) with a plastic working chamber, flow regulator and impellor, and either NBR or EPDM ‘O’-rings. The products are supplied with loose NBR/fibre flange gaskets. Maximum working pressure 16.0 bar. Cold water use only.
Range of pushfit hose connectors with either plastic (white or black) or chrome plated brass bodies and EPDM ‘O’-rings. SHCV prefix models incorporate screwdriver operated servicing valves. All pushfit connections are for use with PEX pipe (manufactured to BS7291-3) and copper pipe (manufactured to EN1057). Barbed end connections are not approved for use with any hose. Chrome plated brass body models are also for use with PB pipe (manufactured to BS7291-2). Maximum working pressure 10.0 bar (servicing valve models only). Barbed end connections are open outlet use only. Cold water use only.
Range of water hammer arrestor’s incorporating brass bodies (various finishes). The 525152 model is supplied with a reinforced captive nut. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C. For products manufactured from June 2023 Maximum operating temperature 85°C
Chrome plated brass quick connector with EPDM washer. Maximum operating temperature 60°C.
‘Para Z’ range of circulating pumps with either stainless steel, bronze or plastic bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘e-SH’ range of centrifugal booster pumps with a blue polymer coated stainless steel body, stainless steel impeller and EPDM ‘O’-rings. Maximum working pressure 12.0 bar. Cold water use only.
Range of shower heads with plastic bodies and a brass inlet connection. The inlet of the shower head incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 70°C.
Shower handset with a plastic body (various finishes - see model). Maximum operating temperature 60°C.
Range of wall mounted and overhead shower outlets, incorporating stainless steel strainers and flow regulators at the inlets. Maximum operating temperature 60°C
Range of overhead showers and shower handsets with plastic body (various finishes). Overhead shower inlets incorporate a stainless steel strainer Maximum operating temperature 60°C.
Range of shower handsets incorporating plastic bodies (various finishes), plastic flow regulators and stainless steel strainers. Maximum operating temperature 60°C.
Range of shower kits, shower outlets and shower hoses. The shower handsets and overhead shower inlets incorporate a plastic flow regulator. Maximum operating temperature 45°C.
Range of shower outlets and shower handsets. The shower heads have a brass body and ball joint, NBR ‘O’-ring, stainless-steel strainer and silicon nozzles. The shower handset has a brass body, NBR ‘O’-rings, silicon nozzles and incorporate a plastic flow regulator on the inlet. Model ‘100274774 N200000068’ is supplied with a double interlocked hose and a single check valve cartridge (to be installed on the inlet to the hose) however the complete product has not been fully tested to demonstrate it provides backflow protection. Model ‘100274774 N200000068’ has a maximum operating temperature of 60°C. All other models have a maximum operating temperature of 85°C.
Range of shower columns with chromium plated brass bodies. Maximum operating temperature 60°C.
Range of shower handsets plastic bodies (various finishes) and EPDM ‘O’-rings. All models include a button on the shower face which alters the spray pattern. The product incorporates either a plastic strainer (26 050 & 26 530) or a stainless-steel strainer and a plastic flow regulator (26 051 & 26 531) on the inlet. Maximum operating temperature 60°C.
Shower bracket, incorporating a brass body(various finishes) and EPDM O’-rings. Maximum operating temperature 85°C.
Range of shower handsets incorporating plastic bodies (various finishes). The inlet incorporates an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of flow switches with plastic bodies. The VKX15M prefix models are supplied with an inline brass adaptor. The VKX05M prefix models are supplied with a brass adaptor for direct insertion into a pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of flow switches with plastic bodies. The VK308/10/15/20/25/32/40/50M and VKS08/10/15/20/25/32/40/50M prefix models are supplied with an inline brass adaptor. The VK305/306/309M and VKS05/06/09M prefix models are supplied with a brass adaptor for direct insertion into a pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of bib taps incorporating brass bodies. The BTHUCV1/2 and BTHUCV3/4 models incorporate an approved single check valve cartridge on the inlet and the outlet (hose union), however, the complete product has not been fully tested to demonstrate it provides backflow protection. The BTHUCV1/2 and BTHUCV3/4 models also incorporate a drain port. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps with brass bodies (various finishes) incorporating non-rising spindle headworks using either dome type or cross top operating members. Spout outlets incorporate plastic flow straighteners. The products are also supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of pillar taps incorporating either stainless steel or brass bodies (various finishes), quarter turn ceramic disc headworks with a single lever operating member. The spout outlet incorporates a plastic aerator. The RB3 models are supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of shower hoses with PVC outer (various finishes - see model), PET reinforcement layer, PVC inner liner and EPDM washers. Maximum operating temperature 65°C.
Range of stainless steel, PVC and nylon braided shower hoses (various finishes), incorporating PVC, EPDM or PEX liners and various end connections.
Range of manually operated, wall mounted, concealed blending valves with brass bodies (various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of manually operated, wall mounted, concealed blending valves with brass bodies (various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member and self-cancelling diverter. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of adjustable T-type thermostatic mixing valves with brass bodies (chrome plated). Each inlet incorporates a stainless steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, bar type, thermostatic shower blending valves (chromium plated brass), incorporating a ¼ turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, concealed, thermostatic shower valves with brass bodies and trim sets (various finishes - see models). Flow is controlled as follows (for operating members - see model): Single outlet models: ¼ turn ceramic disc headwork. Double Outlet Models without diverter: ¼ turn ceramic disc headworks. Double Outlet Models with diverter: 2-way ceramic disc diverter headwork. Triple Outlet Models with diverter: ¼ turn ceramic disc headwork and a 2-way ceramic disc diverter headwork. The temperature is controlled independently via a thermostatic cartridge with various operating members (see model) which incorporates a manual override button. The inlets incorporate a single check valve cartridge, however, the complete assembly has not been tested to demonstrate it provides backflow protection. Specific models are supplied with a shower hose and handset (see models). Maximum working pressure 5.0 Bar Maximum operating temperature 60°C
Wall mounted, bar type, thermostatic shower blending valves (chromium plated brass), incorporating a quarter turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Page 9 of 131
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.