‘AF’ range of compression fittings with brass or chrome plated brass bodies for use with copper pipe (manufactured to EN1057). The AF14 and AF15 tap connector models incorporate an EPDM washer. Maximum working pressure 16.0 bar. Maximum working temperature 85˚C
Range of tee fittings incorporating DZR brass bodies (chrome plated) and approved single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) for use with copper pipe to EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘Tectite Sprint’ range of pushfit fittings with copper or DZR brass bodies. 10mm, 15mm, 22mm & 28mm pushfit fittings are for use with copper pipe (manufactured to BS EN 1057) and polybutylene barrier pipe and cross linked PEX barrier pipe (manufactured to BS 7291). 35mm, 42mm & 54mm pushfit fittings are for use with copper pipe (manufactured to BS EN 1057) only. When used with PB & PEX pipes operating parameter are: 12.0 bar@cold water. 3.0 bar@92°C. When used with copper pipes operating parameter are: 20.0 bar@cold water. 10.0 bar@100°C.
Range of M type press fittings with TP2 copper bodies and EPDM ‘O’-rings, for use with TP2 copper pipe to EN1057. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘Instantor’ range of press-fit fittings incorporating DZR brass or Gunmetal bodies and EPDM ‘O’-rings for use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum working temperature 95˚C.
Dual flush, WC outlet valve controlled with a push button assembly for either full or reduced flush and both models incorporate an internal overflow. Cold water use only.
Range of stainless-steel plate heat exchangers. Maximum operating pressures - primary circuit: 3.0 bar, secondary circuit (DHW): 10.0.bar. Maximum working temperature 80°C.
Under counter electric instantaneous water heater with a stainless steel tank. The flow is controlled via a solenoid valve. The product is supplied with a 3 way isolation valve (15mm compression x 15mm compression x ¾” BSP (M)), as well as a filter head and filter cartridge for installation prior to the under counter unit. LLDPE tubing and pushfit connections are provided for connecting between these items. The filter head inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet to the under counter unit incorporates a combined silicone washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.5 bar. Maximum operating temperature 98˚C. Cold water supply only.
Range of electric combination boilers providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar). The DHW inlet and outlet incorporate spherical servicing valves. Fittited with a CAB device keyless filling link, verifired by test, suitable for category 3 backlfow protection. Maximum working pressure on central heating circuit 2.5 bar & Domestic Hot Water 10bar. Maximum operating temperature 80°C
Hydraulic block assembly comprising of a flow regulator, central heating pump assembly and a stainless-steel plate heat exchanger. Maximum working pressures: DHW circuit: 10.0 Bar Central heating circuit: 2.5 Bar Maximum operating temperature: DHW Circuit: 65.0°C Central heating circuit: 90.0°C
Range of aerators with plastic bodies and chrome plated brass housing. Open outlet use only. Maximum operating temperature 65°C
Range of booster pumps with stainless steel bodies, plastic impellers, and NBR ‘O’-rings. The products incorporate a temperature sensor, pressure sensor, pressure vessel and a non-return valve integral to the pump chamber. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C.
Range of self-priming jet pumps with stainless steel bodies. Maximum working pressure 6.0 bar. Maximum operating temperature 45°C
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of booster sets with a stainless steel manifold system connecting 2 or 3 wholesome water pumps (For BOSS 2HELIX & BOSS 3HELIX models only). The set also includes spherical valves, and a non-return valve Maximum working pressure: 10.0 Bar Maximum operating temperature: 40°C
Range of vertical multistage booster pumps, with stainless steel bodies and impellors. Maximum working pressure is either 16.0 or 25.0 bar depending on specific model. Maximum operating temperature 85°C.
‘Matrix’ range of horizontal multistage stage centrifugal booster pumps with stainless steel bodies, stainless steel impellers, EPDM ‘O’-rings and a carbon/ceramic/EPDM mechanical shaft seal. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of single and twin line shower booster pumps with plastic bodies, plastic impellors, stainless steel motor, NBR ‘O’-rings and EPDM seals. Each suction port incorporates a combined EPDM washer and stainless steel strainer. Maximum working pressure 3.0 bar. Maximum operating temperature 65°C.
Overhead shower outlet with a chrome plated plastic body. The inlet incorporates a stainless-steel strainer. Maximum operating temperature 65°C.
Overhead shower heads with brass bodies (chrome plated) and shower handsets with plastic bodies (chrome plated). The overhead showers incorporate a combined EPDM washer and stainless-steel strainer on the inlet. Maximum operating temperature 65°C.
Page 74 of 311
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.