Concealed WC dual flushing cistern with a vertical BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a pneumatically operated dual flush outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. The inlet supply incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) concealed WC cistern incorporating a side entry compact type float operated inlet valve discharging via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) and a dual or single flush pneumatic or dual flush cable operated drop valve capable of full flush volumes of up to 6 litres with a reduced flush of up to 4 litres. The cistern is operated by manual push button/push plate. One of the side entry inlet valves is mounted internally and is supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Roca Wall Hung W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by a manual push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Vitra wall hung W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 3 litres. The cistern can be operated by manual a push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Vitra wall hung W.C. pan (Ceramic), Thomas Dudley ‘A’ or Illusion Compact Universal frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 3 litres. The cistern can be operated by manual a push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Range of quarter turn ceramic disc headworks incorporating brass bodies and NBR ‘O’-rings. Housed in a brass body. Maximum working pressure 3.5 bar. Maximum operating pressure 60°C.
Range of ceramic cartridge headwork incorporating plastic bodies (various finishes) and NBR ‘O’-rings. The products are intended for insertion into specifically dimensioned tap assemblies. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The product incorporates a pull-out spout outlet with a plastic aerator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a pull-out spray with plastic aerator. The cold Inlet incorporates approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single-hole single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator and some models are supplied with pop-up wastes. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a touchless operation method which operates a solenoid valve which controls the flow and is connected via a hose to the spout outlet. The spout outlets incorporate a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet can incorporate either a plastic flow straightener or a plastic aerator. When supplied with a plastic flow straightener there is a combined EPDM washer and stainless steel strainer behind it. The products are available either as a version with a pop-up waste or one with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Single-hole, single outlet, (fixed) combination tap assembly with brass bodies (chrome plated), incorporating non-rising spindle headworks with cross top operating members. The spout incorporates a plastic flow straighter this product is also supplied with an additional aerator. Model CL4 is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of wall mounted, single hole, single outlet (fixed) combination tap assemblies with chromium plated, DZR brass bodies. The products incorporate a single sequential headwork with a single lever operating member or a push button. The spout outlets incorporate a plastic flow straightener. The inlets incorporate an approved check valve cartridge however, the complete products have not been fully tested to demonstrate it provides backflow protection. Products are supplied with metal back nuts. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic aerator. The product is supplied with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
A range of single hole single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating either ceramic cartridge or quarter turn ceramic disc headwork with a single lever, cross top or dome type operating member. The spout outlets incorporate either a plastic flow straightener or aerator. Model SH-T81072 is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating a rising spindle headwork with a single lever operating member. The spout outlets incorporate a plastic flow straighter and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted, single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a rising spindle headwork with a single lever operating member. The spout outlets incorporate a plastic flow straighter and the products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with ceramic cartridge headworks and single lever operating members. The discharge is via the hand spray outlet or the infra-red controlled outlet on the swivel arm. The cold Inlet has a single check valve assembly (suitable for protection against fluid category 2 backflow). The spouts incorporate a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork controlling the hot and cold flow. The 63264 model also incorporates a push to open, push to close, ‘detent’ headwork intended to control a filtered water supply. The spout outlets incorporate a plastic aerator. The cold water inlet hose is supplied with a chrome plated brass adaptor (½” BSP (F) x ½” BSP (M)) incorporating a check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2). The 63264 model is also supplied with brass tee piece (½” BSP (F) x ½” BSP (M) x spigot (for quick connector)) for connection prior to the brass adaptor containing the check valve cartridge. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with (chromium plated) brass bodies, incorporating quarter turn ceramic disc headworks or ceramic cartridge headworks (see models) with single lever operating members. The swivel spout of the TMO35SSCM model is (chromium plated) stainless steel. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (fixed) combination tap assemblies (various finishes) with electronically controlled functions to allow the tap to dispense boiling water, chilled water or sparkling water from under counter units (not supplied). The spout outlet of ‘Arc’ models incorporates a plastic flow straightener. All models incorporate a separate vent outlet within the tap spout for the near-boiling water circuit. Near-boiling circuit has a maximum operating temperature 100°C. Hot-water circuit has a maximum operating temperature of 65°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a quarter turn ceramic cartridge headwork with single lever operating member. Both inlets incorporate eccentric isolation valves and plastic flow regulators. The spout outlets incorporate plastic flow straighteners. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating two quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating a single sequential headwork which controls flow and temperature with a single lever operating member. Both inlets incorporate eccentric isolation valves, flow restrictors and single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator and the product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted two hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating a single sequential headwork which controls flow and temperature with a single lever operating member. Both inlets incorporate eccentric isolation valves, flow restrictors and single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator and the product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Deck mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), Models M33136 & M1006 incorporate a quarter turn ceramic disc headwork with single lever operating members. Models M4306, M4306E & M4306F incorporate a non rising spindle headwork with dome type operating members. Model M4306G incorporate a non rising spindle headwork with cross top operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. . Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating rising spindle headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
A range of combined bath filler and overflow with a plastic body with a variety of different trims. The products are supplied with a cable operated pop-up waste. For open outlet use only. Maximum operating temperature 65°C.
Range of water filter systems with optional distributor heads. The inlets incorporate a non-return valve. Maximum working pressure 6.9 bar. Cold water use only.
Range on inline filter cartridges incorporating plastic bodies. The filter media varies between models and includes active carbon, silver impregnated active carbon, silver carbon block & weak/strong cationic resin. Maximum working pressure 6.0 bar. Cold water use only.
Uponor S-Press (black and grey) composite fittings, Uponor S-Press composite PPSU reducers with S-Press PLUS composite PPSU nipples, Uponor RS fittings & Uponor S Press Metal Press fittings for use with for use with Uponor MLC pipe. Maximum working pressure and operating temperature: 10.0 bar@70°C Maximum working pressure and operating temperature: 16.0 bar @ Cold water use only.
Range of Eco Duo copper press fittings with EPDM ‘O’-rings for use with Eco-Duo copper tube. The joints are achieved by means of a crimping tool. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Aquaflow polypropylene bodied compression fittings with EPDM ‘O’-rings for use with Elysee PE80 blue pipes. The fittings are supplied with a pipe liner. Above and below ground use. Maximum working pressure 12.5 bar. Cold water use only.
Range of polypropylene push-fit fittings and inserts for use with MDPE pipe (manufactured to BS EN 12201). For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Range of polypropylene push-fit fittings with inserts for use with MDPE Pipe (manufactured to BS EN 12201-2) on one side of the fitting and PB (BS 7291), PEX (BS 7291) or Copper (BS EN 1057) on the other. Models UTS147-DB, UTS197-DB & UTS251-DB are for above and below ground use. All other models are for above ground use only. Maximum working pressure when using 20mm pipe is 16.0 bar. Maximum working pressure when using 25mm & 32mm pipe is 12.5 bar. Cold water use only.
Range of brass press fittings with EPDM ‘O’-rings for use with EN ISO 21003 pipe. Maximum working pressure 10.0 bar. For cold water use only.
Range of brass and copper fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 18.6 bar. Maximum operating temperature 100°C.
Range of single flush siphonic WC outlet valves comprising of a plastic body, LDPE diaphragm washer and stainless steel C link. Cold water use only.
Dual flush, WC outlet valve operated via a push button assembly for either full or reduced flush. Cold water use only
WC dual flush drop valve comprising of a plastic body and silicone seating washer. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water only.
Range of stainless-steel heat exchangers. Maximum working pressure of primary Circuit 3.0 bar. Maximum working pressure of secondary Circuit 10.0 bar. Maximum operating temperature 80˚C
Range of RINNAI continuous flow water heaters with stainless steel plate heat exchangers providing heating and instantaneous hot water .The hot water is generated via a plate heat exchanger. Also supplied is a drain valve and a flow sensing device. Maximum working pressure - 10 bar Maximum working pressure - 85˚C
Shower waste water heat recovery unit, consisting of a PVC-U waste pipe with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10.0 bar. Maximum operating temperature 30°C.
Range of waste water heat recovery systems incorporating a twin wall copper coil (7773414 models) or stainless steel (7771332 models). Maximum working pressure 10.0 bar. Cold water use only.
Range of gas fired condensing water heaters incorporating stainless steel storage tank, buffer tank and strainer on the cold water inlet. Maximum working pressure 10.0 Bar, maximum working temperature 83˚C.
Range of gas fired water heaters incorporating stainless steel strainers on the inlets. Maximum working pressure 10.0 Bar Maximum working temperature 85˚C
Page 7 of 125
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.