Range of tap outlets with plastic bodies incorporating a filter within the body, incorporating a hollow fibre filter membrane. The inlet of the filter incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The filters are supplied with (and must be used with) a chrome plated brass adapter which incorporates a pastic flow regulator. Maximum operating temperature 60°C.
Tigris K5 (PPSU - plastic body) and M5 (DZR brass body) ranges of press-fit (U, H, TH crimp profiles) fittings with stainless steel crimp sleeves and EPDM ‘O’-rings, for use with Tigris K1 multi-layer PEX-c/AL/PE-HD pipe. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Instantor range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Wavin range of Tigris K1 (plastic bodies) and M1 (brass bodies) press-fit fittings for use with Tigris PEX/AL/PE HD (50mm & 63mm) and Tigris PERT/AL/PERT WT (75mm) barrier pipes. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.
Range of solder ring copper fittings for use with copper tube to EN 1057. The HLSRDPMFWT and HLSRDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring brass fittings for use with copper tube (manufactured to EN 1057). The HLSR20CB-d tank connector incorporates an EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
The 3G Metric Imperial range of plastic compression fittings with polypropylene bodies, compression nut and silicone seal for use with PE80 pipe (manufactured to BS EN 12201). Maximum working pressure: Fittings when used with PE100 pipe = 16.0 bar. Fittings when used with PE80 pipe = 12.0 bar. For above and below ground and cold water use only.
Range of M type press fittings with TP2 copper bodies and EPDM ‘O’-rings, for use with TP2 copper pipe to EN1057. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘Instantor’ range of press-fit fittings incorporating DZR brass or Gunmetal bodies and EPDM ‘O’-rings for use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum working temperature 95˚C.
Range of ‘StrengThin™’ 100 System couplings and fittings for use with stainless steel pipe (manufactured to EN 10217-7). For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.
Kuterlite K900 Pro range of compression fittings with DZR brass bodies for use with copper pipe (EN 1254) Maximum working pressure for 8mm-10mm = 70.0 bar. Maximum working pressure for 12mm – 28mm = 20.0 bar. Maximum working pressure for 35mm – 54mm = 6.0 bar. Maximum operating temperature 90°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). The HLE20CB-d tank connector incorporates an EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The HLDPMFWT and HLDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper or gunmetal solder fittings for use with copper pipe. Maximum working pressure 16.0 bar (Sizes 8 - 28mm). Maximum working pressure 10.0 bar (Sizes 35 - 108mm). Maximum operating temperature 100°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Hydraulic block incorporating heat exchangers with pressed stainless-steel plate bodies and copper brazing. Product also incorporates primary and secondary water way with PPS plastic fittings and adaptors and a flow adjustment valve. Maximum operating temperature: Central Heating Circuit: 90°C, Direct Hot Water Circuit: 65°C. Maximum working pressure: Central Heating Circuit: 2.5 bar, Direct Hot Water Circuit: 10 bar.
Water meter incorporating a stop valve, with plastic body and NBR ‘O’-rings. For use with copper pipe manufactured in accordance with EN1057 and plastic PEX pipe manufactured in accordance with BS7291 Class S. Maximum working pressure 10.0 bar. Cold water use only
Range of aerators with plastic bodies and chrome plated brass housing. Open outlet use only. Maximum operating temperature 65°C
Page 60 of 207
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.