Range of ultrasonic water meters with brass (DN15-50) or plastic (DN15-20 only) bodies, EPDM ‘O’-rings and a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pressure sensors with stainless steel bodies, EPDM ‘O’-ring and ceramic measuring cell. Maximum working pressure 25.0 bar. Cold water use only.
Range of tapping tees with gunmetal bodies and plastic fitting, for use with SDR11 & SDR17 Polyethylene barrier pipes (manufactured to BS8588). For pipe diameters between 63mm & 90mm, the adaptor plate must be used. When used with SDR11 pipes the maximum working pressure is 16.0 bar. When used with SDR17 pipes the maximum working pressure is 10.0 bar. Cold water use, for below ground only.
Range of pressure transmitters with stainless steel bodies. The DST P140 G1/4 A (with O-ring) model also incorporates an EPDM ‘O’-ring. Maximum working pressure 50.0 bar. Maximum operating temperatures: DST P140 G1/4 A (with O-ring): 85°C, All other models: 90°C.
Range of flexible joints incorporating an EPDM (inner & outer) joint with a steel reinforcing ring and two carbon steel flanges. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.

Range of pressure transmitters with stainless steel bodies. Maximum working pressure 50.0 bar. Maximum operating temperatures 90°C.
Range of cast iron (blue epoxy coated) (G versions only) or stainless steel (all other versions - F, N, R, T) vertical multistage pumps with stainless steel impellers, shaft and outer sleeve. Maximum working pressures: 16 bar, 25 bar and 40 bar. Oval flanges - Body type ‘T’ (1SV-3SV, 5SV, 10SV, 15SV-22SV) - 16 bar. Round flanges - Body type ‘R’ (1SV-3SV, 5SV, 10SV, 15SV-22SV) - 25 bar. Round flanges - Body type ‘F’ (1SV-3SV) - 25 bar. Round flanges - Body type ‘N’ (10SV) - 25 bar. Round flanges - Body type ‘N’ (66SV-92SV) - 16 bar. Round flanges - Body type ‘G’ (33SV, 46SV) - 40 bar. Round flanges - Body type ‘G’ (33SV, 46SV, 66SV-92SV, 125SV) - 16 bar. Round flanges - Body type ‘G’ (125SV) - 25 bar. Cold water use only.
Range of electronic booster pumps with variable speed, incorporating stainless-steel bodies, impellers and shaft, EPDM gaskets and seals and an expansion vessel on the outlet. The pumps incorporate a drain port. Maximum working pressure 10.0 bar. Cold water use only.
Range of circulating pumps, with plastic or stainless steel (cast EN 1.4308) bodies and a plastic impeller. Maximum working pressures: Stainless steel bodied pumps 10.0 bar, Plastic bodied pumps 3.0 bar. Maximum operating temperature 95°C.
Range of shower handsets and shower heads with (plastic bodies - various finishes) Some models incorporate a plastic flow restrictor, or a check valve with built in flow regulator (however, the complete product has not been fully tested to demonstrate it provides backflow protection) or neither (See models for FR or WSCV). Maximum operating temperature 60.0°C Open outlet use only
Overhead shower outlet with chrome plated plastic body incorporating a filter and a flow regulator. The product incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature 60°C..
Range of wall mounted shower outlets with brass bodies (chrome plated). The outlet of the 32971 and 65295 models incorporates an approved check valve cartridge, however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum operating temperature 70°C.
Range of Y-patterned strainers with blue epoxy coated ductile iron bodies and a stainless-steel mesh strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of flow switches with plastic bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 293LK | None | 1/2" BSP (M) | 16 bar | 85 °C | Company logo, size and BS1010-2 | Body | Yes | Rising spindle | Not Applicable | Not Applicable |
Range of single hole, single outlet (fixed) pillar taps (chromium plated brass), incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Range of pillar taps, (chromium plated brass) incorporating a quarter turn ceramic disc headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of stainless steel braided or nylon braided EPDM lined hose assemblies available with a variety of end connectors. Maximum operating pressure 10.0 bar. Maximum operating temperature 90°C.
Range of “Tempest” Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 5.5 bar & Solar circuit 5.5 bar. Maximum operating temperature 70°C.
Ranges of free standing stainless steel cylinders. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C
Page 584 of 590
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.