| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| B005* | Various | ½" captive nut | 10 bar | 65 °C | WINSDRUM | On Spout | No | 1/4 Turn ceramic disk | Metal Backnuts | Aerator | Interconnecting Hoses, |
* denotes finish and can be replaced by: C - Chrome RG - Rose Gold BTG - Brushed Titanium gold BZG - Brushed Zirconium gold BRG - Brushed Rose gold MW - Matte white BS - Brushed stainless BN - Brushed nickel PN - Polished nickel GM - Gunmetal B - Matte black TG - Titanium gold ZG - Zirconium gold BC - Black+chrome W - White CW - Chrome+white Q - Quartzite ZGC - Zirconium gold+chrome TGC - Titanium gold+chrome M - Medieval A - Antique bronze CP - Champagne BL - Brushed lead BP - Polished Black
Range of three-hole, single outlet (fixed) wall mounted combination tap assemblies, (brass bodies - various finishes). Incorporating a quarter turn ceramic disc headwork with lever or cross top operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of combined bath waste and overflow assemblies in various finishes.(see models for finishes) Maximum operating temperature: 60ºC
Range of free-standing sanitary macerating disposal units. The units are fed via a flexible hose assembly. Flow is controlled by a solenoid valve and discharges via a type `AB` air gap (verified by test, suitable of fluid category 5 backflow protection). Maximum working pressure 6.0 Bar Maximum operating temperature 40.0°C
Range of monochloramine generators incorporating UPVC pipework, fittings and an external flow sensor. Maximum working pressure 6.0 bar. Cold water use only.
Range of green Sappro butt-welded polypropylene fittings for use with Sappro PPR pipes. Maximum working pressure: 20 Bar. Maximum operating temperature: 23°C.
U Profile range of press fittings incorporating EPDM ‘O’-rings. For use with Mingshi (S-1-0509/10/11/12/17/13) PEX-AL-PEX pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C
F1C compression & F5 press fittings for use with B1 multilayer PEX/AL/PEX pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of DZR brass compression fittings for use with Q-Therm PEX-b Pipes (SDR 7.4) Maximum working pressure:20 bar, cold water use only
EG Range of copper, brass capillary lead free solder ring fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of compression fittings with brass, chrome plated brass bodies. For use with copper pipe (EN 1057) Maximum operating pressure 16 bar. Maximum operating temperature 85°C
Range of compression fittings with brass, nickel plated brass bodies for use with copper pipe (manufactured to EN 1057). For above ground use only. Max working pressure 16.0 bar. Max operating temperature 85°C.
‘BF’ range of Brass compression fittings for use with copper pipe manufactured to EN1057 Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of compression fittings with polypropylene bodies for use with PE100 pipe (manufactured to EN 12201). Some of the female adaptors (55920-9-L, 55920-10-L, 55920-11-L & 55920-11-M), female threaded elbows (56935-10-L, 56935-11-L & 56935-11-M) have a maximum working pressure of 10.0 bar. All other models have a maximum working pressure of 16.0 bar. For above and below ground, cold water use.
Range of stainless-steel press fittings (SUS304 or 316L) with EPDM ‘O’-rings for use with stainless-steel pipe (SUS304 or 316L EN 10312), using an ‘M’ press profile. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
5000 series of copper end feed fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Dual flush, WC outlet valves for either full or reduced flush. Incorporates an internal overflow. Cold water use only.
Range of dual flush WC outlet valves operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Stainless steel plate heat exchangers with copper brazing.
Range of water meters with brass bodies. The inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature is 50°C or 85°C, please refer to model.
Page 509 of 590
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.