Range of stainless-steel pressure sensors. Maximum working pressures: B83.a-b-C5-3-f-g-h-i-j-k-l-m-n-o (Thread G1): 10.0 bar. B83.a-b-cd-e-f-g-h-i-j-k-l-m-n-o with METEC - metallic measuring cell: 25.0 bar, B83.a-b-cd-e-f-g-h-i-j-k-l-m-n-o with Piezoresistive - metallic measuring cell: 40.0 bar. Maximum operating temperature 100°C
Range of flow sensors with brass bodies (various grades - see model). Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
Range of electric water pumps, with stainless steel bodies, shaft and either stainless steel or plastic impellors. Maximum working pressure 8.5 Bar. Maximum operating temperature: See models.
Range of self-priming electric booster pumps with plastic bodies incorporating plastic impellers with variable speed settings, and a non-return return valve (not suitable for backflow protection). Maximum working pressure 4.5 Bar Maximum operating temperature 50.0°C
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| S34011 | Chrome plated | 1/2" BSP (M) | For open outlet use only bar | 75 °C | DOMOO | Body | No | ||||
| S06041 | Chrome plated | 1/2" BSP (M) | For open outlet use only bar | 75 °C | DOMOO | Body | No | ||||
| S185015(88500103) | Chrome plated | 1/2" BSP (M) | For open outlet use only bar | 65 °C | DOMOO | Body | No |
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 37902W-MB5 | BLACK | ½” BSP | OPEN OUTLET bar | 60°C °C | MIRA SHOWERS | SPRAY PLATE | No | Not applicable | Not Applicable | Open Outlet | Handset, |
| 37902W-MG5 | GREEN | ½” BSP | OPEN OUTLET bar | 60°C °C | MIRA SHOWERS | SPRAY PLATE | No | Not applicable | Not Applicable | Open Outlet | Handset, |
| 37902W-GB5 | BLUE | ½” BSP | OPEN OUTLET bar | 60°C °C | MIRA SHOWERS | SPRAY PLATE | No | Not applicable | Not Applicable | Open Outlet | Handset, |
| 37902W-CS5 | GREY | ½” BSP | OPEN OUTLET bar | 60°C °C | MIRA SHOWERS | SPRAY PLATE | No | Not applicable | Not Applicable | Open Outlet | Handset, |
| 37902W-BP5 | PINK | ½” BSP | OPEN OUTLET bar | 60°C °C | MIRA SHOWERS | SPRAY PLATE | No | Not applicable | Not Applicable | Open Outlet | Handset, |
| 37903W-MB5 | BLACK | ½” BSP | OPEN OUTLET bar | 60°C °C | MIRA SHOWERS | SPRAY PLATE | No | Not applicable | Not Applicable | Open Outlet | Fixed Head, |
| 37903W-MG5 | GREEN | ½” BSP | OPEN OUTLET bar | 60°C °C | MIRA SHOWERS | SPRAY PLATE | No | Not applicable | Not Applicable | Open Outlet | Fixed Head, |
| 37903W-GB5 | BLUE | ½” BSP | OPEN OUTLET bar | 60°C °C | MIRA SHOWERS | SPRAY PLATE | No | Not applicable | Not Applicable | Open Outlet | Fixed Head, |
| 37903W-CS5 | GREY | ½” BSP | OPEN OUTLET bar | 60°C °C | MIRA SHOWERS | SPRAY PLATE | No | Not applicable | Not Applicable | Open Outlet | Fixed Head, |
| 37903W-BP5 | PINK | ½” BSP | OPEN OUTLET bar | 60°C °C | MIRA SHOWERS | SPRAY PLATE | No | Not applicable | Not Applicable | Open Outlet | Fixed Head, |
Range of drain cock elbows incorporating a DZR brass body, for use with copper pipe (manufactured to BS EN 1057). Maximum working pressures:16.0 bar. Maximum operating temperature 85°C.
Flexible safety hose assembly with PVC, composite inner hose and corrugated outer cover incorporating EPDM gaskets. The inlet of the hose incorporates a plastic strainer. The hose is fitted with an integral device which is intended to stop the flow of water (please note that this function has not been verified by test). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of ‘THINK-A-FLEX’, EPDM lined, stainless steel braided flexible hose assemblies incorporating various end connections Maximum working pressure: 10 BAR Maximum operating temperature: 65°C
Range of stainless steel braided silicone lined flexible hose assemblies with various end connections. Maximum working pressure 10.0 Bar. Maximum operating temperature 70°C.
Range of gas fired, unvented hot water storage heaters. The DHW circuit consists of a temperature and pressure relief valve (set at 7.0Bar). Maximum working pressure: 6.5 Bar. Maximum operating temperature: 85°C.
Range of single or double tank water heaters, incorporating enamel coated carbon steel tank. The secondary circuit is factory fitted with a temperature and pressure relief valve (10.0 Bar). Maximum working pressure 8 bar. Maximum operating temperature 75 °C.
Range of 2, 3 and 4 port manifold assemblies with either DRZ brass (3834.1, 3834.34, 3835.34, 3835.1, 3837.37 & 3837.1) or brushed chrome plated brass bodies incorporating screw down isolation valves with dome type operating members at each of the outlets. Maximum working pressure: 16 Bar. Maximum operating temperature: 95°C.
Range of wall mounted manually operated, concealed shower valves (brass bodies – various finishes) incorporating ceramic cartridge headworks with single lever operating members and a manual diverter to shower outlets with single lever operating members. Maximum working pressure 10.0 Bar. Maximum operating temperature 65°C.
Range of wall mounted shower valves with brass bodies with various finishes (see models). The products incorporate a ceramic cartridge headwork with a single lever operating member that controls both the flow and temperature. Maximum working pressure; 10 Bar Maximum operating temperature; 60°c
Range of wall mounted thermostatic shower valves with (brass bodies – various finishes), incorporating a 2-way ceramic disc diverter controlling the flow to either the shower handset or an overhead shower using a single lever operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The product is supplied with an overhead shower, riser rail, shower hose and handset. The inlet to the overhead shower incorporates a plastic strainer. The product incorporates approved single check valves at the inlet, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure; 10 Bar Maximum operating temperature; 60°c
Range of wall mounted thermostatic shower valves (brass bodies – various finishes) incorporating either a 2-way ceramic disc diverter (model TVT11000200061) controlling the flow to either an overhead shower or bath filler with dome operating members or a quarter turn ceramic disc headwork to shower handset. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate stainless steel strainers and approved check valve cartridge(s), however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature is 60°C.
Range of concealed, wall mounted thermostatic shower valves with brass bodies (chromium plated trim sets). The products incorporate a one or two-way function and a thermostatic cartridge controlling the temperature with lever type operating members. All models incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating pressure 10 bar. Maximum operating temperature 60°C
Range of flanged butterfly valves with either lever or hand wheel operation and a blue epoxy coated ductile iron body. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.

Range of butterfly valves with blue epoxy coated ductile iron bodies, stainless steel discs with EPDM seats and a lever operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Page 494 of 522
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.