Deck mounted; two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with brass back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The product is supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
---|---|---|---|---|---|---|---|---|---|---|---|
193805 X XXX | VARIOUS | ¾” BSP | 10 bar | 65 °C | PPI | BODY | No | 1/4 Turn ceramic disk | Metal Backnuts | Aerator | Shower Hose, Handset, |
X XXX Denotes the following: First X: Different handle and the second, third & fourth XXX for different finishes: Handles: A (Lever type) Chrome – No suffix, Brushed brass – BGP, PVD Gold – PVD, Brushed Nickel – BN1, Gun Metal – GMG, Matt Black – MBK, Matt White – MWH, Stainless Steel – SS1, Black Chrome – BCP, Titanium – TIB and Antique Bronze – AB1.
Range of three-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes). Incorporating quarter turn ceramic disc headworks with cube type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed thermostatic basin mixing valves with brass bodies. Temperature is controlled via a thermostatic cartridge and flow is controlled by solenoid valves actuated by an infrared sensor. The outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar. Maximum operating temperature 60.0°C.
Range of deck mounted spout outlets, (brass bodies - various finishes) incorporating a plastic aerator. Open outlet use only. Maximum operating temperature 60°C.
‘MUFA’ and ‘MUPA’ ranges of expansion vessels with epoxy coated bodies. ‘MUFA’ models have a maximum working pressure of 8.6 bar. ‘MUPA’ models have a maximum working pressure of 10.0 Bar. Cold water use only.
Inline filter with plastic body. Maximum working pressure 5.0 bar. Cold water use only.
Range of in-line water filter cartridges with plastic bodies. Maximum working pressure 8.0 bar. Cold water use only.
Range of press fittings (brass bodies - various finishes) with stainless steel press (Unipress MLCP ) collars and EPDM O-rings for use with “EA” range of PEX/AL/PEX multilayer pipe (for press fitting connections and compression for EHA adaptor fittings only) or copper pipe manufactured to EN1057 (compression connections). Maximum operating temperature: 95°C. Maximum operating pressure: 10 bar.
Range of DZR Brass and Bronze compression fittings for use with VIALLI PEXa pipe. Maximum working pressure 10.0 bar. Cold water use only.
Range of stainless steel press fittings to be used with stainless steel pipes. Connection is achieved via M profile press jaws. For above ground and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘APL’ & 'AP' ranges of brass press fittings for use with ‘APE Multylayer' pipe. Connection is achieved via TH or U profile press jaws. AP range, only TH profile; APL range, TH and H profile; TH and H profile from DN 16 to DN32; TH for DN40, DN50 and DN63. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Dual flush WC syphon, with a polypropylene body and stainless-steel link for use with WC flushing cisterns. Cold water use only.
Range electric, instantaneous, open outlet, mains water heaters. Maximum working pressure 6.6 bar. Maximum operating temperature 70 ˚C.
Electric instantaneous water heater with a plastic casing. Flow is controlled via a solenoid valve operated by an infrared sensor. Temperature is controlled by a dial on the front of the unit. The product incorporates a swivel arm outlet from the base. Maximum working pressure 3.0 bar. Maximum operating temperature 48˚C. Cold supply only.
Range of heat interface units incorporating a heat exchanger, flow sensor, spherical valve and shock arrestor. The heating circuit incorporates a pressure relief valve set at 3.0 bar. Maximum working pressure & operating temperature: Primary circuit is 16.0 bar & 90°C. Domestic hot water circuit is 10.0 bar & 65°C. Heating circuit is 2.5 bar & 80°C.
Range of in-line water meters with brass or plastic bodies. Models with a minimum length of 130mm and a maximum operating temperature of 50°C are supplied with an optional, non-return valve to be fitted by the installer (not suitable for backflow protection). Maximum working pressure 16.0 bar. The meters can be supplied with a maximum operating temperature of 50°C or 70°C.
Range of in-line ultrasonic water meters with brass bodies and plastic housing. Maximum working pressure 16.0 Bar Maximum operating temperature 50.0°C
Direct coupler (brass with a range of finishes). Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Page 493 of 578
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.