Range of two-hole, single outlet, fixed, combination tap assemblies (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporate a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet, (fixed) combination tap assemblies, (brass bodies – various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. Model (TVW125003000xx) is supplied with a click type waste (verified by test). Maximum working pressure 10.0 Bar Maximum operating temperature 60°C.
Range of wall mounted two-hole, single outlet fixed combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with dome or lever type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60⁰C.
Two hole, single outlet fixed combination tap assembly (chrome plated brass body) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts and a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a quarter turn ceramic disc headwork controlling the flow using a dome type operating member. Temperature is controlled via a thermostatic cartridge also using a dome type operating member with a manual override button, and the product also incorporates a manual diverter to shower outlet. The inlets incorporate a stainless-steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Two hole, single outlet, fixed combination tap assembly (chromium plated brass) incorporating ceramic disc headwork with single lever operating members and manually operated bath to shower diverter. The outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Two-hole, single outlet (fixed) combination tap assembly (brass bodies – various finishes) incorporating a quarter turn ceramic disc headwork with single lever operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The inlets incorporate a stainless strainer and an approved single check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset. Maximum working pressure 10 bar. Maximum operating temperature 65 °C
Range of two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with handwheel (T782001 model) or single lever operating members (all other models), and a self-cancelling diverter to shower outlet. The spout outlet of the T781001 & T782001 models incorporates a plastic aerator, all other models incorporate a plastic aerator including a stainless steel mesh. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of combined bath fillers and overflow waste assemblies with plastic bodies (various finishes). The outlet incorporates a plastic aerator and the product is supplied with a cable operated pop-up waste. Maximum operating temperature 60°C.
Range of combined bath filler and/or waste and overflow assemblies (see models) in various finishes. Open outlet use only Maximum operating temperature: 60ºC
Range of tap adaptors with chrome plated (brass or plastic) bodies. The outlet of some models incorporates a plastic flow restrictor. The side mount adaptors (except 90-001801) incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The side mount adaptors (except 90-001804) incorporate a piston type component which is intended to stop the flow to change the filter. All side mount adaptors and 90-001869 & 90-001873 Fixed Position Adaptors have a maximum working pressure of 5.0 bar. All other models are open outlet use only. Maximum operating temperature 60°C.
Range of exposed bath fillers (brass body, various finishes) incorporating a ceramic cartridge headwork, controlling both flow and temperature with a single lever operating member. The products incorporate integrated overflow and click type pop-up waste systems. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of wall mounted spout outlets (brass bodies - various finishes). The outlet incorporates a plastic aerator. Maximum operating temperature 60°C. Open outlet use only.
Range of swivel or fixed spout outlets (chromium plated brass) incorporating a plastic aerator. Open outlet use only Maximum operating temperature 60.0°C
‘Flofix’ range of expansion vessels.
Range of expansion vessels with fibreglass bodies and butyl diaphragms. Maximum working pressure: 8.6 Bar. Maximum operating temperature: 23 °C.
Range of filters with DZR brass bodies, stainless steel sieve. All models incorporate a drain tap and are supplied with a pressure gauge. Maximum working pressure 25.0 bar. Cold water use only.
Range of CU type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of CU type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Page 493 of 566
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.