‘Uponor S-Press Plus’ compatible pipe and fittings system consisting of Uponor MLC pipe and Uponor Uni Pipe for use with Uponor S-Press plus metal and PPSU fittings. Maximum working pressure and operating temperature: 10.0 bar@70°C. Maximum working pressure and operating temperature: 16.0 bar @ Cold water use only.
Range of stainless steel press-fit fittings and pipes, the fitttings incorporating stainless steel bodies and EPDM O-ring. Joints are made using a pressing tool for M profile. All the models are for both above ground and below ground use. YHPFM304 models are made of SS304 stainless steel, used with Yuhe SS304 pipes manufactured to EN10312. YHPFM316L models are are made of SS316L stainless steel, used with Yuhe SS316L pipes manufactured to EN10312. Maximum working pressure 16 bar. Maximum operating temperature 85°C.
Range of stainless steel press-fit fittings (316L or 304) and pipes (SUS316L or SUS304 - EN 10312), the fitttings incorporate EPDM O-rings. Crimp joint is achieved by a M profile crimp jaws. Maximum operating pressure 16 bar. Maximum operating temperature 85°C
Range of MM and MC press fit fittings with PPSU bodies incorporating stainless steel crimp sleeves and EPDM O-Rings for use with AIS XPERT multi-layer pipes. Maximum working pressure is 10.0 bar. Maximum operating temperature is 70°C.
Range of press fit fittings with PPSU bodies incorporating stainless steel crimp sleeves and EPDM O-Rings for use with Multitubo multi-layer pipes. Maximum working pressure is 10.0 bar. Maximum operating temperature is 70°C.
‘Tweetop system’ consisting of brass bodied nickel plated, compression or press fit (‘U’ crimping profile) fittings for use with ‘Tweetop multilayer pipe’ PERT/AL/PERT. Maximum working pressure 10.0 Bar. Maximum working temperature 95°C.
Range of brass (Series 1000 & 1100) and DZR brass (Series 1100CZ) compression fittings, various finishes. For use with copper tube EN1057. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.
Range of copper and brass press-fit fittings with HNBR o-rings, for use with copper tube manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
SAB A16 range of fittings for use with PE pipes (manufactured to EN12201-2). Supplied with a plastic pipe support liner For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
FloPlast "Supreme" range of fittings for use with PE pipes (manufactured to EN12201-2). Supplied with a plastic pipe support liner For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
NORMA MARLIN range of fittings for use with PE pipes (manufactured to EN12201-2). Supplied with a plastic pipe support liner For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Range of Talbot pushfit fittings with polyprolylene or acetal bodies and EPDM o-rings for use with MDPE PE80 pipe (BS EN 12201). For use above and below ground use. Maximum working pressure 16 bar. Cold water use only.
‘AquaGas M range’ of copper and brass press fit fittings with NBR ‘O’-rings for use with copper tube (manufactured to BS EN 1057). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
‘DELBRAZE’ range of copper and copper alloy braze fittings for use with copper pipe (EN1057). Maximum working pressure: 16 bar. Maximum working temperature: 85°C.
Range of pipe repair clamps incorporating EPDM double seals. The products are intended for use with stainless steel pipe manufactured to EN1124. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of plate heat exchangers with stainless steel plate bodies and copper brazing. Maximum working pressure: 45 Bar. Maximum operating temperature: 99 °C.
Range of wall mounted, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel, pressure relief valve set at 3.0 bar and flow regulators. The inlets to both domestic hot water and primary circuits are controlled via screwdriver operated angled spherical valve. The primary circuit can be filled via a built in CAB device, that has been verified by test (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 80°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of integrated water circuits with plastic bodies and EPDM ‘O’ rings and gaskets. The assemblies incorporate flow switches, plate heat exchangers and plastic flow regulators. The primary circuit incorporates a 3.0 bar rated pressure relief valve. Maximum working pressures: 2.5 bar primary circuit, 10.0 bar secondary circuit. Maximum operating temperature 85°C.
Range of water meters with epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Cold water use only.
Range of electromagnetic water meters with blue epoxy coated aluminium bodies and a natural rubber liner. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Page 48 of 113
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.