WC flushing cistern incorporating a bottom entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3 litres. The cistern is operated by a pnuematic push button. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC cistern in white plastic incorporating a BS 1212-4:2016 side entry float operated inlet valve providing a Type AG air gap arrangement and a single or dual flush outlet valve. The full flush can be set at 6 litres and the reduced flush can be set at 3 litres. The inlet supply incorporates a servicing valve. Maximum operating pressure 10.0 bar. Cold water use only.
Range of concealed WC cistern in white plastic incorporating a BS 1212-4:2016 side entry float operated inlet valve providing a Type AG air gap arrangement and a single or dual flush outlet valve. The full flush can be set at 6 litres and the reduced flush can be set at 3 litres. The inlet supply incorporates a servicing valve. Maximum operating pressure 10.0 bar. Cold water use only.
Standpipe assembly break tank with a Type ‘AB’ air gap (verified by test – suitable for backflow protection against fluid category 5) mounted to the top of the standpipe body. The tank is filled via a compact float valve and has two screened weir slots. Water is then supplied by gravity from the break tank to the hose outlet below. Flow is activated via a spherical valve located behind a lockable panel. In addition to the isolation valve, the product incorporates a single check valve assembly (suitable for backflow protection against Fluid Category 2) prior to the spherical valve and an in-line ‘Y’ pattern strainer after it. The spherical valve includes a drain plug to allow for draining. Insulation is provided up to the drain point. Maximum working pressure 10.0 bar. Cold water use only.
DC type pipe interrupter with a permanent atmospheric vent (DZR brass body) incorporating a flow regulator at the inlet and brass shroud. Maximum working pressure 10.0 bar. Cold water use only.
Range of non-verifiable double check valve assemblies with DZR brass bodies, incorporating two spring loaded, resilient trim in-line check valve cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Ceramic cartridge headwork with a plastic body, silicone gaskets and seals. For insertion into specifically dimensioned tap bodies. Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Thermostatic cartridge incorporating brass bodies and stainless steel filters. For insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of thermostatic cartridges incorporating brass bodies, stainless steel strainers and EPDM ‘O’-rings. For insertion into specifically dimensioned tap bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of deck mounted combination tap assemblies (chromium plated brass) incorporating rising spindle headwork with single lever operating members, swivel spout outlet and separate pull-down spray outlet (with self-closing trigger assembly). The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Models 98008-M001 & 98008-1 are single hole, single outlet. Model 98007-1 is two-hole, single outlet. Model 98001-2 is single hole, double outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted combination tap assemblies (chromium plated brass) incorporating rising spindle headwork with single lever operating members, swivel spout outlet and separate pull-down spray outlet (with self-closing trigger assembly). The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Model 98011-1 is single hole, single outlet. Models 98002-1 & 98002-M001 are two-hole, single outlet. Model 98002MN-2 is two-hole, double outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a pull-out spray with plastic aerator. The cold Inlet incorporates approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies incorporating chromium plated or stainless steel plated brass bodies, ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Some models are supplied with a click type waste (fully tested). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chrome plated brass), incorporating a thermostatic sequential headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with (chromium plated) brass bodies, incorporating quarter turn ceramic disc headworks or ceramic cartridge headworks (see models) with single lever operating members. The swivel spout of the TMO35SSCM model is (chromium plated) stainless steel. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork controlling the hot and cold flow. MAL models incorporate a quarter turn ceramic disc headwork to control a filtered water supply. The spout outlets incorporate a plastic aerator. The inlets incorporate a check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Two-hole, single outlet (fixed) combination tap assembly with a brass body (chromium plated), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet is a waterfall design. The inlets incorporate plastic flow restrictors. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Models 91742, 95660 incorporate a non-rising spindle headwork with dome type operating members. Model 21775 incorporate a non-rising spindle headwork with cross top operating members. Model 77174 incorporate a quarter turn ceramic disc headwork with single lever operating members. The fitting incorporates a manual diverter to the shower outlet The spout outlet incorporates a plastic flow straightener and the products are supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of two hole, metal single outlet (fixed) combination tap assemblies (various finishes). Incorporating either quarter turn ceramic disc or non-rising headwork with various operating members and a self-cancelling diverter to shower outlet. The spout outlets incorporate a plastic flow straightener and the product is supplied with plastic or metal backnuts, hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn rising spindle headworks with single lever operating members. The S8215AA model is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
Page 45 of 508
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.