Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. Maximum working pressure 10.0 bar. Cold water use only. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. For use with cold water only
Range of bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. Maximum working pressure 10.0 bar. Cold water use only.
Concealed BS EN 14055: 2018 WC flushing cistern incorporating a side or bottom compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 4 litres. The cistern can be operated by touch free electronic or manual push button / push plate options. The supply hose incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Concealed BS EN 14055: 2018 WC flushing cistern incorporating a side or bottom entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by touch free electronic or manual push button / push plate options. Maximum working pressure 10.0 bar. Cold water use only.
Range of wall hung concealed WC flushing cisterns with a BS 1212-4 float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a push button assembly. Maximum working pressure - 10 Bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed BS EN 14055: 2018 WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 4 litres. The cistern can be operated by touch free electronic or manual push button / push plate options. The supply hose incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Wall mounted, two-hole, single outlet (fixed) combination tap assemblies (brass body – various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout incorporates a self-cancelling diverter to shower outlet with Type HC device (verified by test - suitable for backflow protection against Fluid Category 3). The threaded shower connection incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure - 10 Bar. Maximum operating temperature - 60 °C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass body). Incorporating quarter turn ceramic disc headworks, dome type operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator or flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 70.0°C
Wall mounted two hole, single outlet (fixed) combination tap assembly with chromium plated brass body. Incorporating a ceramic cartridge headworks with a single lever operating member and a self-cancelling diverter to a shower outlet with a Type HC backflow protection device (verified by test - suitable for backflow protection against Fluid Category 3) The spout outlet incorporates a plastic aerator. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure: 10 Bar. Maximum working temperature: 60°C.
Concealed 2-way or 3-way brass body diverter valve (see models) with or without shut off mechanism (see model) and various trim sets and operating members (see model). Maximum working pressure: 5.0 Bar. Maximum operating temperature: 60.0°C.
Concealed self-cancelling control with a Type HC backflow protection device (verified by test - suitable for backflow protection against Fluid Category 3). (brass body) with a variety of operating member styles. Maximum working pressure: 5.0 Bar. Maximum operating temperature: 60.0°C.
DC type pipe interrupter with a permanent atmospheric vent (DZR brass body) incorporating a flow regulator at the inlet and brass shroud. Maximum working pressure 6.0 bar. Cold water use only.
Range of CAb backflow prevention devices with plastic bodies, incorporating EPDM seals and diaphragm. Filling link with manual or automatic tap. Maximum working pressure 3.0 bar. Maximum operating temperature 65°C.
Range of stainless steel calorifiers. Max working pressure 10 bar. Max operating temperature 90°C.
Range of quarter turn ceramic disc and non-rising spindle headworks. Maximum working pressure 10.0 Bar Maximum operating temperature 85 °C.
Range of ceramic cartridge headworks with a plastic body. For insertion into specifically dimensioned bodies. Maximum working pressure 10.0 Bar. Maximum operating temperature 85 °C.
Page 424 of 505
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.