Range of lever operated spherical valves with a nickel-plated brass body and a chrome plated brass ball, NBR ‘O’-rings and PTFE seats. Maximum working pressure 30.0 bar. Maximum operating pressure 85°C.
Range of in-line lever or butterfly operated spherical valves with nickel plated brass bodies and nickel plated brass balls. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of flanged ductile iron, blue epoxy coated gate valves with EPDM seats and hand wheel operating members. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of resilient seated gate valves with blue epoxy coated ductile iron bodies and ductile iron wedges encapsulated in EPDM. The valve is operated via a non-rising spindle. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of resilient seated gate valves with blue epoxy coated ductile iron bodies, and an EPDM wedge, gasket and ‘O’-ring. The 166 30 SERIES model has a rising spindle, the 166 33 SERIES model has a non-rising spindle, both have a handwheel operating member. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of gate valves with blue epoxy coated ductile iron bodies and EPDM coated ductile iron wedges. The valves operate via non-rising spindle headwork. Maximum working pressure 16.0 bar and a maximum operating temperature 85°C.
M profile press fit gate valves (brass bodies) controlled via a handwheel with PTFE seals. Connection is achieved via M profile press jaws, to be used with copper pipe EN1057. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
Range of gate valves with ductile iron bodies (blue epoxy coated) with EPDM coated ductile iron wedge and non-rising stem operated via a hand wheel operating member. Maximum working pressure: 16 bar. Maximum operating temperature: 80°C
Range of screw down stop valves with brass bodies, EPDM gaskets and PTFE washers. For use with copper pipe to EN 1057. Maximum working pressure 16.0 Bar. Maximum operating temperature 99°C.
Screw down stop valves with brass bodies and dome type operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of cold-water inlet control groups consisting of an in-line, manually adjustable pressure reducing valve and a pressure relief valve pre-set at either 6.0 or 8.0 bar, housed within DZR brass bodies. The products incorporate approved check valve cartridges; however, the complete products have not been fully tested to demonstrate they provide backflow protection. The pressure reducing valves also have stainless-steel strainers. Maximum inlet pressure 16.0 bar. Cold water use only. CWIC351300 – Outlet pressure range 1.0 to 3.5 bar. Pressure relief valve set at 6.0 bar CWIC351301 – Outlet pressure range 1.0 to 2.1 bar. Pressure relief valve set at 8.0 bar. CWIC351303 – Outlet pressure range 1.0 to 3.5 bar. Pressure relief valve set at 8.0 bar CWIC351306 – Outlet pressure range 1.5 to 6.0 bar. Pressure relief valve set at 8.0 bar
Inlet control group with a DZR brass body, consisting of a pressure reducing valve and pressure relief valve (6.0 Bar). The inlet incorporates a stainless-steel strainer, and the outlet incorporates an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The product is for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C. Outlet pressure range of the pressure reducing valve is 1.0 to 4.0 bar.
Range of in line regulating valves with brass bodies, EPDM `O` rings. The valves incorporate a non-rising spindle headwork for temperature regulation. Max working pressure: See models. max operating temperature: See models.
Range of in-line electrolytic scale reducers with copper bodies for use with copper pipe (manufactured to BS EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 40°C.
In-line electrolytic scale reducer with chromium plated copper body for use with copper pipe manufactured to BS EN 1057. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of ultraviolet disinfection units consisting of a stainless-steel body and quartz sleeve. Maximum working pressure: 10.0 bar. Maximum operating temperature: 25.0°C.
Oasis Kalix range of water dispensers which dispenses hot and cold water. The flow is controlled via a solenoid valve and the products are activated via a push button or infrared sensor. The products incorporate a pressure relief valve with a plastic body which is rated at 5.0 bar. Maximum working pressure 3.0 bar Please refer to model for maximum operating temperature.
Range of commercial and domestic ion exchange water softeners (salt regenerated). Operation is by an electronically controlled ion exchange resin filled plastic pressure vessel with integral salt cabinet (domestic models) or separate brine tank (commercial models). Maximum working pressure 8.0 bar. Cold water use only.
'JSGL-SRC (U)'. Factory applied, grey coloured Sulphate resistant cement. Mix cement:sand:water in a 1:1.7:0.4 weight ratio and apply as per manufacturer's Work Instructions 'JSGL/WI/14', issue no, '02', revision no. '00', dated '29.09.2018'. Cure for 24 hours@23°C and then 4 hours@45°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'JSGL-OPC (E)'. Factory applied, grey coloured Ordinary Portland cement. Mix cement:sand:water in a 1:1.7:0.4 weight ratio and apply as per manufacturer's Work Instructions 'JSGL/WI/14', issue no, '02', revision no. '00', dated '29.09.2018'. Cure for 24 hours@23°C and then 4 hours@45°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
Page 388 of 505
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.