Section Code 2420 : Drinking.
Back To Directory SectionsIn-line water chiller unit intended to supply a water fountain. The product is supplied with a loose in-line stainless steel strainer. Maximum working pressure 7.25 bar. Cold water use only.
In-line water chiller unit intended to supply a water fountain. The product is supplied with a loose in-line stainless steel strainer. Maximum working pressure 7.25 bar. Cold water use only.
Range of under counter units providing (near) instant boiling and chilled water (Quadra/Sahara /Eco models) or chilled and ambient water (Alpine 125 model) through the XL, XT or XR taps. Where products are supplied with the XL, XT, XR taps the flow is controlled via a solenoid valve incorporating a plastic strainer which is activated by a lever (XL tap), touch method (XT tap) or a remote control (XR tap). The under counter units incorporate a combined pressure limiting valve (set at 5.0 Bar) and a double check valve assembly (suitable for backflow protection against Fluid Category 3) on the inlet and are supplied with a loose stainless steel braided PEX lined flexible hose assembly incorporating a ½” captive nut end connection for installation on the inlet. The under counter units also incorporate a water filter on the cold supply after the solenoid valve. The filter head inlet incorporates an approved single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides adequate backflow protection - but is incorporated after the double check valve assembly). (The filter is installed downstream of the combined pressure limiting valve and a double check valve assembly). The Quadra and Sahara plus models incorporate a venturi block assembly fed [cold water] from and then [hot water from hot tank] back to a mixer tap (not supplied). The venturi block assembly incorporates an approved check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides adequate backflow protection). Under counter unit supplying XL, XT, XR taps: Maximum inlet pressure 10.0 bar. Cold supply only. Maximum working temperature of the instantaneous heater (where incorporated - model dependent) 98.5°C. Quadra and Sahara plus models mixer tap (not supplied) cold supply and hot water circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Counter-top water dispenser providing instantaneous hot and cold water. Flow to the hot water tank is controlled by a solenoid valve and actuated via a water level sensor. The discharge of both hot and chilled water is operated by self-closing tap assemblies. The product incorporates a pressure reducing valve set at 0.9 bar. The inlet incorporates an approved single check valve cartridge; however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection. Maximum working pressure 7.0 bar. Maximum operating temperature 96°C. Cold water supply only.
Range of cold or cold carbonated water cooler units with the flow controlled via solenoid valve. The product incorporates a double check valve assembly. Maximum working pressure 3.5 Bar. Cold water use only.
Range of cold or cold carbonated water cooler units with the flow controlled via solenoid valve. Maximum working pressure 3.5 Bar. Cold water use only.
‘NIAGARA FAMILY’ range of free standing or table top, ambient, chilled or sparkling water (with gas) dispensing units with flow controlled via either a solenoid operated push button or an external tap or dispensing equipment. The units incorporate solenoid valves, PE hoses, plastic fittings. Models including ‘WG’ as part of the model incorporate a non-verifiable single check valve assembly (suitable for backflow protection against Fluid Category 2). The ACWG (EC) models incorporates a pump and a carbonating unit. The outlets incorporate a plastic aerator. Maximum working pressure 6.0 bar. Cold water use only.
`River` range of drinking water fountains which dispense ambient and/or chilled water. Flow is controlled via self-closing headworks. Maximum working pressure 6.0 bar. Cold water use only
Range of under-sink mounted water chiller with a stainless-steel cooling tank and plastic fittings Maximum working pressure 3.0 bar. Maximum operating temperature 38°C.
Range of inline under counter water chillers incorporating stainless steel coil tubing. Maximum working pressure 5.5 Bar. Cold water use only.
Range of under-counter or counter-top drinking water dispensers delivering still ambient, still chilled & sparkling water. HygienePlus®. Models incorporate a built-in filter system. The flow is controlled by a solenoid valve which is either operated by a touch or a touch pad. The water is dispensed via a tap arrangement on under-counter versions or an integrated outlet on counter-top versions. The inlets incorporate an approved check valve cartridge assembly however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Cold water use only.
Range of water fountains and bottle fillers, water fountains which can be chilled or ambient outlet temperatures, incorporating a solenoid controlling the flow which is activated via either a push button or IR activated sensor. Split level models incorporate both bottle filler and fountain outlets. Maximum working pressure 7.0 bar. Cold water use only.
Range of undercounter or deck mounted drinking water fountains which dispense ambient and/or chilled water. Flow is controlled via a solenoid valve and the products are activated via a push button or infa-red sensor . Maximum working pressure 7.0 bar. Cold water use only.
Water chiller unit for under counter installation, to be used in conjunction with an outlet tap arrangement or flow control device (not supplied as part of this approval). Maximum working pressure 7.0 bar. Cold water use only.