Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass or stainless steel), comprising of a concealed rough in set with a brass body and a variety of separate trim sets incorporating a ceramic cartridge headwork with a dome type or single lever operating member and a spout outlet. The spout outlet incorporates a plastic aerator. The products are supplied with click type (click clack) waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted two hole, metal, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a 2 way ceramic disc diverter controlling the flow between the spout outlet and the shower outlets with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member which incorporates a manual override button. The product incorporates a secondary manual diverter to divert the flow between the overhead shower and the shower hose and handset. The spout outlet incorporates a plastic aerator. The inlets and the outlet to the shower handset all incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Two hole, single outlet (fixed) combination tap assembly with brass body (various finishes). Incorporating quarter turn ceramic disc headworks, and self cancelling diverter to shower outlet. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly with brass body (chrome plated), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener, and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with various operating members (see models). The products are supplied with two stainless steel braided EPDM lined flexible hose assemblies with ½” captive nut end connections for installation between the side valves and the spout. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The product is supplied with stainless steel braided PEX lined flexible hose assemblies with M8 x ⅜” captive nut end connections and a combined NBR washer and stainless steel strainer (x2) for installation between the side valves and the brass tee piece to the spout. The inlets of the brass tee piece incorporate an approved single check cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with two loose fibre gaskets for installation on each inelt hose. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar Maximum operating temperature 60°C
Range of three hole, single outlet (fixed) wall mounted, concealed tap assemblies with brass bodies and chrome plated trim set. Consisting of a rough in set 45089 and extermnal trim 65090 and 65091. Incorproating a quarter turn ceramic disc headworks and single lever operating members.The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Four-hole, single outlet (fixed) combination tap assembly (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlet incorporates a self-cancelling diverter to the shower outlet and a plastic flow straightener with stainless steel mesh strainer. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlets incorporate a self-cancelling diverter to the shower outlet and a plastic flow straightener with a stainless-steel mesh strainer. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlets incorporate a self-cancelling diverter to shower outlet and a plastic flow straightener with stainless steel mesh. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
A range of four-hole single outlet fixed combination tap assemblies with brass bodies in a variety of finishes (See models). Incorporating ¼ ceramic disc headworks with single lever operating members and a self-cancelling diverter to a shower outlet. The spout outlet incorporates a plastic aerator. The shower outlet elbow incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. This product is supplied with a shower hose, shower handset and metal screw clamp type back nuts. The side valves and the spout are connected with a copper tube. Maximum working pressure 10 bar. Maximum working temperature 60 °C.
Range of wall elbows incorporating brass bodies (various finishes) and various back plates. Maximum operating temperature 95ºC.
‘Comisa’ range of brass bodied press-fit and threaded fittings for use with `Comisa’ (PE-RT/AL/PE-LMD) multi-layer pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
ERA-01 range of SDR11 and SDR17 polyethylene butt welded fittings for use with ERA-02 range of SDR11 and SDR17 PE 100 pipe. SDR11 rated pipe and fittings have a maximum working pressure of 16.0 bar. SDR17 rated pipe and fittings have a maximum working pressure of 10.0 bar. For above and below ground use. Cold water use only.
Boss Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of press-fit end connectors (gunmetal bodies) for use with copper pipe manufactured to BS EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of brass tee fittings for use with copper pipe to EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Turbo 44R dual flush syphonic flushing apparatus with a polypropylene body and stainless steel link for use with WC flushing cisterns.
Range of floor standing gas fired combination boilers providing domestic hot water via a stainless-steel plate heat exchanger. Unit is supplied with a safety relief valve (8.0 bar). Maximum working pressure 7.5 bar. Maximum operating temperature 85°C.
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressure relief valve set at 3.0 bar. The supplies to both primary hot water and secondary are controlled via spherical valves. The boilers incorporate a filling loop assembly which incorporates a double check valve assembly (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 82°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Page 27 of 326
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.